・Power supply voltage = 12 → 240 V ac/dc
・Time range = 0.1 seconds → 100 hours
・Mounting type = DIN rail
・Number of timer functions = Multi-function
・Number of contacts = 2
・Series = RE17
・Time increment = hours, minutes, seconds
・Contact configuration = SPDT
・Maximum current = 8 A
・Terminal type = screw
・Minimum voltage = 12 V ac/dc
・Maximum voltage = 240 V ac/dc
・Minimum operating temperature = -20℃
Product Code | Range of product | Product or component type | Device short name | mUsn rated supply voltage | Vibration resistance | Shock resistance | Nominal output current | Maximum switching current | Maximum switching voltage | Electrical durability | Mechanical durability | Width | Height | Depth | Net weight | IP degree of protection | Electromagnetic compatibility | Standards | Relative humidity | Ambient air temperature for operation | Ambient air temperature for storage | Product certifications | Sustainable offer status | EU RoHS Directive | Mercury free | RoHS exemption information | China RoHS Regulation | Environmental Disclosure | Circularity Profile | Maximum power consumption in W | Local signalling | REACH Regulation | Supply frequency | Tightening torque | Marking | Compatibility code | Discrete output type | Minimum switching current | Contacts type and composition | Connections - terminals | mUimpn rated impulse withstand voltage | Contacts material | Insulation resistance | Breaking capacity | Safety reliability data | Control type | Reset time | Mounting support | Immunity to microbreaks | Dielectric strength | Mounting position | Housing material | Power consumption in VA | Repeat accuracy | Temperature drift | Time delay range | On-load factor | Time delay type | Functionality | Voltage range | Release of input voltage | Voltage drift | Setting accuracy of time delay | Control signal pulse width | Operating frequency | Power on delay | Creepage distance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RE17RMMW | Zelio Time | Modular timing relay | RE17R | 12...240 V AC/DC 50/60 Hz | 20 m/s2 (f= 10 to 150?Hz) conforming to IEC 60068-2-6 | 15 gn for 11?ms conforming to IEC 60068-2-27 | 8?A | 8?A AC/DC | 250?V AC | 100000?cycles (8?A at 250?V AC maximum) for resistive load | 10000000?cycles | 17.5?mm | 90?mm | 72?mm | 0.07?kg | IP20 (terminal block) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529 | Electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2 Electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4 1.2/50 ƒÊs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5 1.2/50 ƒÊs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5 Conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11 Voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11 Conducted and radiated emissions: , class B, conforming to EN 55022 | 2006/95/EC EN 61000-6-3 IEC 61812-1 EN 61000-6-2 EN 61000-6-1 2004/108/EC EN 61000-6-4 | 93?% without condensation conforming to IEC 60068-2-30 | -20 to 60 Ž | -30 to 60 Ž | CSA GL CULus | Green Premium product | Pro-active compliance (Product out of EU RoHS legal scope) ?EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | End of Life Information | 1.5?W at 240 V DC | LED indicator for on steady: relay energised, no timing in progress LED indicator for flashing: timing in progress 80 % ON and 20 % OFF LED indicator for pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) 5 % ON and 95 % OFF | REACH Declaration | 50...60 Hz +/- 5 % | 0.6 to 1?N.m conforming to IEC 60947-1 | CE | RE17 | Relay | 10?mA at 5 V DC | 1 C/O | Screw terminals, 1 x 0.5...1 x 3.3 mm2 (AWG 20...AWG 12) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm2 (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm2 (AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm2 (AWG 24...AWG 16) flexible with cable end | 5?kV during 1.2/50 ƒÊs | Cadmium free | 100 MOhm at 500?V DC conforming to IEC 60664-1 | 2000?VA | MTTFd = 296.8 years B10d = 270000 | Selector switch front panel | 120?ms on de-energisation typical | 35 mm DIN rail conforming to EN/IEC 60715 | 20?ms | 2.5?kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1 | Any position in relation to normal vertical mounting plane | Self-extinguishing | 0 to 3?VA at 240 V AC | +/- 0.5 % conforming to IEC 61812-1 | +/- 0.05 %/Ž | 1...10 h 0.1...1 s 6...60 s 10...100 h 6...60 min 1...10 s 1...10 min | 100?% | A, Ac, At, B, Bw, C, D, Di, H, Ht | Multifunction | 0.85...1.1 Us | 5 V | +/- 0.2 %/V | +/- 10 % of full scale at 25 Ž conforming to IEC 61812-1 | 100 ms with load in parallel typical 30 ms typical | 10?Hz | 100?ms | 4 kV/3 conforming to IEC 60664-1 |
Part Number |
---|
RE17RMMW |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship |
---|---|---|---|---|---|
฿ 1,665.00 ฿ 1,175.32 | MULTIFUNC TIMER 1CO 12 | 1 Piece(s) | 60 Day(s) |
Loading...
Dimension width(mm) | 17.5 mm | Range | Zelio Time | Minimum Operating Temperature | -20°C |
---|---|---|---|---|---|
Maximum Operating Temperature | 60°C | Type | Modular timing relay | Maximum Switching Voltage AC | 250 V AC |
Switching Current | Maximum 8 A AC/DC / Minimum 10 mA at 5 V DC |
Please check the type/dimensions/specifications of the part RE17RMMW in the Schneider Electric, Timer Relay, Multi-Function, RE17RMMW series.