Molded Case Circuit Breakers (MCCB) NF-FAU Series

Caution
- This product belongs in RoHS Directive under Category 9 "Monitoring and control equipment" with exclusion from the usage restriction of phthalate esters until 21 July 2021.
Product Description
WS Series NF-F Type no-fuse breaker.
[Features]
· Small, high performance, and economical no-fuse breaker.
· UL and cUR compatible.
· NF30-FAU, NF50-FAU, NF50-FHU.
[Applications]
· No-fuse breaker, general-purpose product.
NF-F Type No-Fuse Breaker External Appearance of MITSUBISHI Circuit Breakers

NF30-FAU Circuit Breakers

NF50-FAU Circuit Breakers

NF50-FHU Circuit Breakers
NF-F Type No-Fuse Breaker Specifications of MITSUBISHI Circuit Breakers
| Type Circuit Breakers | No-Fuse Breaker | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Frame A | 30 | 50 | 50 | ||||||
| Type Name | NF30-FAU | NF50-FAU | NF50-FHU | ||||||
| Phase Wire System (Note 1) | - | - | - | ||||||
| Number Of Contacts | 2 | 3 | 2 | 3 | 2 | 3 | |||
| Rated Current A (Standard Ambient Temperature 40°C) | 5 10 15 20 30 | 5 10 15 20 30 40 50 | 3 5 10 15 20 30 40 50 | ||||||
| Rated Current For Motor Protection (Note 8) | 2 4 6.3 8 16 | 0.3 0.4 0.6 0.8 1.2 1.4 2 2.5 4 7.1 8 12 16 25 32 45 | |||||||
| Electrical Leakage Properties | High Speed Type | Rate Sensitivity Current I △n mA | - | - | - | ||||
| Pickup Current UL1053 | - | - | - | ||||||
| Maximum Operating Time s Or Less At 5I Δn (Note 2) | - | - | - | ||||||
| Electrical Leakage Display Method | - | - | - | ||||||
| Rated Short Circuit Breaking Capacity kA | UL 1077 CSA C22.2 No. 235 | Rated Voltage | AC (V) | 240 | 240 | 240 | |||
| DC (V) | 60 | 60 | - | ||||||
| AC | 240 V | 2.5 (Note 3) | 2.5 (Note 3) | 5 | |||||
| DC | 60 V | 1.5 | 1.5 | - | |||||
| IEC 60947-2 EN 60947-2 (Icu/Ics) | Rated Insulation Voltage (V) | 250 | 250 | 500 | |||||
| AC | 400 V | - | - | 1.5/1 | |||||
| 230 V | 2.5/1 (Note 4) | 2.5/1 (Note 4) | 5/2 | ||||||
| DC | 60 V | 1.5/1 | 1.5/1 | - | |||||
| GB 14048.2 (Icu/Ics) | Rated Insulation Voltage (V) | 250 | 250 | 500 | |||||
| AC | 415 V | - | - | 1.5/1 | |||||
| 240 V | - | - | 5/2 | ||||||
| 230 V | 2.5/1 (Note 4) | 2.5/1 (Note 4) | - | ||||||
| DC | 60 V | 1.5/1 | 1.5/1 | - | |||||
| JIS C 8201-2-1 Ann.1 Ann.2 (Icu/Ics) | Rated Insulation Voltage (V) | 250 | 250 | 500 | |||||
| AC | 415 V | - | - | 1.5/1 | |||||
| 200 V | 2.5/1 (Note 4) | 2.5/1 (Note 4) | 5/2 | ||||||
| DC | 65 V | 1.5/1 | 1.5/1 | - | |||||
| JIS C 8201-2-2 Ann.1 Ann.2 (Icu/Ics) | Rated Operating Voltage AC (V) | - | - | - | |||||
| AC | 200 V | - | - | - | |||||
| 100 V | - | - | - | ||||||
| Rated Impulse Withstand Voltage Uimp (kV) | 2.5 | 2.5 | 4 | ||||||
| Current Type | AC/DC shared | AC/DC shared | AC | ||||||
| Isolation Compliant | - | - | - | ||||||
| Reverse Connections | - | - | - | ||||||
| External Dimensions (mm) | a | 40 | 60 | 40 | 60 | 50 | 75 | ||
| b | 72 | 72 | 96 | ||||||
| c | 57 | 57 | 60 | ||||||
| ca | 73.5 | 73.5 | 76 | ||||||
| Product Mass kg | 0.14 | 0.2 | 0.16 | 0.22 | 0.25 | 0.37 | |||
| Mounting Method | IEC 35 mm Rail | ◎(Standard support for mounting IEC 35 mm rail) | ◎(Standard support for mounting IEC 35 mm rail) | ◎(Standard support for mounting IEC 35 mm rail) | |||||
| Mounting Screw (Note 5) | Possible | Possible | Possible | ||||||
| Front Plate Installation (Note 6) | Possible | Possible | - | ||||||
| Electrical Appliance And Material Safety Law | compliant | Compliant | Compliant | ||||||
| CE Mark | TÜV certification | TÜV certification | TÜV certification | ||||||
| CCC Certification | acquired | acquired | acquired | ||||||
| Overcurrent Tripping Method | Thermal | Thermal | Completely electromagnetic | ||||||
| Trip Button | -(Note 7) | -(Note 7) | -(Note 7) | ||||||
Note 1: When using a 3-contact earth leakage breaker for 1 ø 2 W, do not use the center contact. Connect the left and right contacts.
When using for 1 ø 3 W, connect the center contact to a neutral wire. (UL cannot use 1 ø 3 W.)
Note 2: 0.1 for UL1053.
Note 3: The rated breaking capacity is 1.5 kA for parts with 5 A rated current.
Note 4: The rated breaking capacity is 1.5/1 kA for parts with 5 A rated current.
Note 5: The customer must provide the mounting screws. For details, please refer to the catalog.
Note 6: Can install surface plate without tightening nuts from the back. (The customer must provide the mounting screws M5 × 0.8 × 30) Here, terminal screws can be tightened from the back of the breaker.
Note 7: Only included when an alarm switch (AL) is attached. (Excludes NF30-FAU and NF50-FAU SHT+AL)
Note 8: For rated current for motor protection, only current sensitivities of 30 mA or 50 mA can be manufactured.
External Dimensions of MITSUBISHI Circuit Breakers

Voltage Fluctuation Range of MITSUBISHI Circuit Breakers
| Rated Voltage | Applicable Circuit Voltage | Variable Voltage Range In Which Electrical Leakage Protection Function Can Operate |
|---|---|---|
| 100-200 V | 100/110/200/220 V | 80 to 242 V |
| 240 V (UL) | 240 V | 132 to 264 V |
| 240 V (GB) | 240 V | 204 to 264 V |
| 230 V | 240 V | 195 to 253 V |