PANASONIC PLC (Input/Output Units)

PLC (Input/Output Units) products in the Electrical & Controls category from PANASONIC. The product can be selected based on many product specifications such as Number Of Inputs, Input Format, Rated Input Voltage, Input answer time, Number of Outputs. PANASONIC offers products around 2 items and the product specifications can easily be compared. Parts and equipment for controlling machines and electrical systems. Controllers and power supplies. PANASONIC products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.
CAD
2 items
Sort By
30
60
90
  1. 1
  • You can add up to 6 items per a category to the compare list.
    FP7 Multi-Input/Output Unit

    FP7 Multi-Input/Output Unit

    PANASONIC

    1 unit provides multiple functions.

    [Features]
    · High-functioning control is possible for a low cost.
     With the low-cost CPU unit AFP7CPS21 (50,000 yen), high-functioning control is possible from 80,000 yen. *Based on manufacturer's suggested price.
    · Settings are run in FPWIN GR7
    The settings of the unit can be done easily from the configuration screen.

    *The product pictured is AFP7MXY32DWD.
    From: ฿ 13,178.42
    Days to Ship: day to ship Quote
    day to ship Quote
  • You can add up to 6 items per a category to the compare list.
    FP7 Input/Output Unit

    FP7 Input/Output Unit

    PANASONIC

    Can efficiently install the required number of I/O.

    [Features]
    · Combined input/output unit is available
    Using the combined input/output unit makes it possible to efficiently install the required number of I/O. Provides a more compact size of PLC at a lower cost.
    · A current capacity of 300 mA is also installed in the transistor output unit of the 64-point output unit
    8 contact points with a current capacity of 300 mA are mounted on a 64-point transistor output unit.
     It is now possible to directly operate large display lights and magnetic contact points.
    · Adjusting the input time constant can counteract noise
    Choose from response times of 0.1 ms, 0.5 ms, 1.0 ms, 5.0 ms, 10.0 ms, 20.0 ms or 70.0 ms according to the output device used.

    *The product pictured is AFP7X16DW.
    From: ฿ 5,710.70
    Days to Ship: day to ship 40 Day(s)
    day to ship 40 Day(s)
Brand
Product Series
From
Days to Ship
Number Of Inputs
Input Format
Rated Input Voltage(V)
Input answer time
Number of Outputs
Output Format
Rated load voltage(V)
Protection function
Connection Terminal
Representative Standard
You can add up to 6 items per a category to the compare list.
FP7 Multi-Input/Output Unit
You can add up to 6 items per a category to the compare list.
FP7 Input/Output Unit
Brand

PANASONIC

PANASONIC

Product Series

FP7 Multi-Input/Output Unit

FP7 Input/Output Unit

From

฿ 13,178.42

฿ 5,710.70

Days to Ship Quote 40 Day(s)
Number Of Inputs1616 ~ 32
Input FormatOtherDC input
Rated Input Voltage(V)-DC12~24 ~ 24 DC
Input answer time-Less than 1 mS
Number of Outputs1632
Output FormatOtherTransistor / source output
Rated load voltage(V)--
Protection function--
Connection TerminalConnectorTerminal Block / Connector
Representative StandardUL / CULCE / UL / CUL

Loading...

  1. 1

Related Categories to PLC (Input/Output Units)

FAQ PLC (Input/Output Units)

Question: What is a PLC (Programmable Logic Controller) and How Do Input/Output Units Function in Automated Systems?
Answer: A PLC, or Programmable Logic Controller, is the brains behind many automated systems. It's like a specialized computer designed for controlling machines and processes. PLCs use Input/Output (I/O) units to communicate with sensors and actuators in the actual system. These I/O units serve as the interface between the digital world of the PLC and the physical world of your machines. Inputs gather data from sensors, while outputs send control signals to devices like motors and valves, allowing the PLC to make decisions and automate tasks.
Question: How Do PLC Input/Output Units Interface with Devices and Sequencers in Industrial Automation?
Answer: PLC I/O units interface with devices through wiring connections. Inputs are connected to sensors or switches, while outputs are linked to devices like motors, valves, or lights. The PLC's programming defines how inputs and outputs interact. For example, an input from a temperature sensor might trigger an output to turn on a cooling fan. PLCs can also work in sequence, performing a series of tasks based on inputs and previous outcomes. This sequence can be programmed to control complex industrial processes.
Question: How Do I Install and Program PLC Input/Output Units for Optimized Control in Automated Machinery?
Answer: Installing PLC I/O units involves mounting them in a control panel, connecting wires, and ensuring proper electrical connections. To program a PLC for optimized control, you'll use specialized software to create a logic program. This program defines how the PLC responds to different inputs and manages outputs. It's essential to understand your machinery's requirements, design a logical program, and thoroughly test it to ensure efficient and safe operation.
Question: In Which Industrial Applications Are PLCs Commonly Used?
Answer: PLCs are incredibly versatile and can be found in various industrial applications. They're widely used in manufacturing for tasks like assembly line control and quality assurance. They're also essential in processes like water treatment, energy production, and food production. Basically, anywhere automation and precise control are needed, you'll often find PLCs at the heart of the operation.