[Features]
· Tank/hopper type
· Covers a wide range, from 20 kg to 5 tons, with a high accuracy of 1/5,000.
· Structure resists the effects of eccentric loads, making it ideal for weighing moving items.
· For both tensile and compression use.
Part Number |
---|
LC1205-K020 |
LC1205-K050 |
LC1205-K100 |
LC1205-K200 |
LC1205-K500 |
LC1205-T001A |
LC1205-T002 |
LC1205-T005 |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | Main applications | Type | Capacity (g) | Dust-proof and waterproof function | Specification details | JAN Code | Details of dust-proof and waterproof function | Weight (kg) | Supplement |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 9,558.95 | MEASURING INSTRUMENT | 1 Piece(s) | 61 Day(s) | Weighing instruments | Main Body | 20390 | Available | - | 4981046613989 | IP54 | 0.3 | Rated capacity (mass): 200 N (20.39 kg), Rated output: 1.5296 mV/V±0.5%, Tolerable load: 200% of R.C., Overload limit: 250% of R.C., Overall error: 0.02% of R.O., Recommended applied voltage: 5 to 12 V DC, Zero balance: ±2% of R.O., Input terminal resistance: approx. 400 Ω, Output terminal resistance: 350±3.5 Ω, Insulator resistance: 5,000 MΩ/50 V DC, Zero point temperature influence: 0.07% of R.O./10°C, Output temperature influence: 0.02% of Load/10°C Typ., Cable thickness/length: ø6 / 3 m, Cable color: | ||
฿ 9,558.95 | MEASURING INSTRUMENT | 1 Piece(s) | 61 Day(s) | Weighing instruments | Main Body | 50990 | Available | - | 4981046613996 | IP54 | 0.3 | Rated capacity (mass): 500 N (50.99 kg), Rated output: 1.5296 mV/V±0.5%, Tolerable load: 200% of R.C., Overload limit: 250% of R.C., Overall error: 0.02% of R.O., Recommended applied voltage: 5 to 12 V DC, Zero balance: ±2% of R.O., Input terminal resistance: approx. 400 Ω, Output terminal resistance: 350±3.5 Ω, Insulator resistance: 5,000 MΩ/50 V DC, Zero point temperature influence: 0.07% of R.O./10°C, Output temperature influence: 0.02% of Load/10°C Typ., Cable thickness/length: ø6 / 3 m, Cable color: | ||
฿ 10,358.07 | MEASURING INSTRUMENT | 1 Piece(s) | 61 Day(s) | Weighing instruments | Main Body | 102000 | Available | - | 4981046614009 | IP54 | 0.4 | Rated capacity (mass): 1 kN (102.0 kg), Rated output: 2.0394 mV/V±0.5%, Tolerable load: 200% of R.C., Overload limit: 200% of R.C., Overall error: 0.02% of R.O., Recommended applied voltage: 5 to 12 V DC, Zero balance: ±2% of R.O., Input terminal resistance: approx. 400 Ω, Output terminal resistance: 350±3.5 Ω, Insulator resistance: 5,000 MΩ/50 V DC, Zero point temperature influence: 0.07% of R.O./10°C, Output temperature influence: 0.02% of Load/10°C Typ., Cable thickness/length: ø6 / 3 m, Cable color: | ||
฿ 11,126.87 | SCALE | 1 Piece(s) | 61 Day(s) | Weighing instruments | Main Body | 203900 | Available | - | 4981046614016 | IP54 | 0.5 | Rated capacity (mass): 2 kN (203.9 kg), Rated output: 2.0394 mV/V±0.5%, Tolerable load: 200% of R.C., Overload limit: 200% of R.C., Overall error: 0.02% of R.O., Recommended applied voltage: 5 to 12 V DC, Zero balance: ±2% of R.O., Input terminal resistance: approx. 400 Ω, Output terminal resistance: 350±3.5 Ω, Insulator resistance: 5,000 MΩ/50 V DC, Zero point temperature influence: 0.07% of R.O./10°C, Output temperature influence: 0.02% of Load/10°C Typ., Cable thickness/length: ø6 / 3 m, Cable color: | ||
฿ 10,373.24 | MEASURING INSTRUMENT | 1 Piece(s) | 61 Day(s) | Weighing instruments | Main Body | 509900 | Available | - | 4981046614023 | IP54 | 0.5 | Rated capacity (mass): 5 kN (509.9 kg), Rated output: 2.0394 mV/V±0.5%, Tolerable load: 200% of R.C., Overload limit: 200% of R.C., Overall error: 0.02% of R.O., Recommended applied voltage: 5 to 12 V DC, Zero balance: ±2% of R.O., Input terminal resistance: approx. 400 Ω, Output terminal resistance: 350±3.5 Ω, Insulator resistance: 5,000 MΩ/50 V DC, Zero point temperature influence: 0.07% of R.O./10°C, Output temperature influence: 0.02% of Load/10°C Typ., Cable thickness/length: ø6 / 3 m, Cable color: | ||
฿ 12,846.45 | MEASURING INSTRUMENT | 1 Piece(s) | 61 Day(s) | Weighing instruments | Main Body | 1020000 | Available | - | 4981046614030 | IP54 | 1.3 | Rated capacity (mass): 10 kN (1.020 t), Rated output: 2.0394 mV/V±0.5%, Tolerable load: 200% of R.C., Overload limit: 200% of R.C., Overall error: 0.02% of R.O., Recommended applied voltage: 5 to 12 V DC, Zero balance: ±2% of R.O., Input terminal resistance: approx. 400 Ω, Output terminal resistance: 350±3.5 Ω, Insulator resistance: 5,000 MΩ/50 V DC, Zero point temperature influence: 0.07% of R.O./10°C, Output temperature influence: 0.02% of Load/10°C Typ., Cable thickness/length: ø6 / 5 m, Cable color: | ||
฿ 15,982.30 | MEASURING INSTRUMENT | 1 Piece(s) | 61 Day(s) | Weighing instruments | Main Body | 2039000 | Available | - | 4981046614047 | IP54 | 1.3 | Rated capacity (mass): 20 kN (2.039 t), Rated output: 2.0394 mV/V±0.5%, Tolerable load: 200% of R.C., Overload limit: 200% of R.C., Overall error: 0.02% of R.O., Recommended applied voltage: 5 to 12 V DC, Zero balance: ±2% of R.O., Input terminal resistance: approx. 400 Ω, Output terminal resistance: 350±3.5 Ω, Insulator resistance: 5,000 MΩ/50 V DC, Zero point temperature influence: 0.07% of R.O./10°C, Output temperature influence: 0.02% of Load/10°C Typ., Cable thickness/length: ø6 / 5 m, Cable color: | ||
฿ 19,993.11 | MEASURING INSTRUMENT | 1 Piece(s) | 61 Day(s) | Weighing instruments | Main Body | 5099000 | Available | - | 4981046614054 | IP54 | 1.9 | Rated capacity (mass): 50 kN (5.099 t), Rated output: 2.0394 mV/V±0.5%, Tolerable load: 200% of R.C., Overload limit: 200% of R.C., Overall error: 0.02% of R.O., Recommended applied voltage: 5 to 12 V DC, Zero balance: ±2% of R.O., Input terminal resistance: approx. 400 Ω, Output terminal resistance: 350±3.5 Ω, Insulator resistance: 5,000 MΩ/50 V DC, Zero point temperature influence: 0.07% of R.O./10°C, Output temperature influence: 0.02% of Load/10°C Typ., Cable thickness/length: ø6 / 5 m, Cable color: |