[Features]· Universal AC input / Full range.· Withstand 300 V AC surge input for 5 seconds.· Built-in active PFC function.· Protections: Short circuit / Overload / Overvoltage / Over temp. (optional for HRP-75 / HRP-100)· Built-in constant current limiting circuit.· Built-in remote sense function (HRP□-150 / 200)· No load power consumption <0.5 W (except for HRP-150/200)· Built-in remote ON/OFF control (except for HRP-150/200)· Built-in 5 V / 0.3 A standby output (HRPG-150/200)· Cooling by free air convection.· 1U low profile.· LED indicator for power on.· 100% full load burn-in test.
Part Number |
---|
HRP-600-24 |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | Capacity (W) | Output voltage (Single only) | Rated output current (single only) (A) | Included Function | Representative Standard | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Input Voltage (V) | Rated output current 1 for DC 24 V (A) | Rated output current 2 for DC 12 V (A) | Output voltage variation range (V) | AC Input Voltage Range | AC Input current (Maximum) | DC adjustment range | Effi. | Overload protection | Over voltage protection | Withstand Voltage | Operating temperature | Safety Standard | EMC standards | Other authentication/standards |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 5,753.55 | SWITCHING POWER SUPPLY | 1 Piece(s) | Available | Same day | 600 ~ 648 | DC24V | 27 | Fan for cooling | CE / UL / CUL / TUV | 105 ~ 218 | 63.5 ~ 105 | 63.5 ~ 248 | - | 27 | - | - | 85~264VAC; 120~370VDC | Cold start, 70A at 230VAC | ±15% rated output voltage | 88.0% | 105%~135% Constant current limiting, auto-recovery | 115%~145% | I/P - O/P: 3kVAC, I/P - FG: 1.5kVAC, O/P - FG: 0.5kVAC, 1 minute | -40~+70°C (refer to output derating curve) | UL60950-1, TUV EN60950-1 approved | EN55022 class B, EN61000-4-2,3,4,5,6,8,11, EN61000-3-2,3, EN61000-6-2 heavy industry level | - |
Loading...
Shape | With Cover | Single/multi | Single | Input Voltage | AC/DC |
---|---|---|---|---|---|
Input/output terminal shape | Screw |
Please check the type/dimensions/specifications of the part HRP-600-24 in the Switching Power Supply (PFC Series) series.
Part Number |
---|
HRP-100-24 |
HRP-200-24 |
HRP-300-24 |
PSP-600-12 |
PSP-600-24 |
RST-10000-48 |
Part Number | Price | Minimum Order Qty | Volume Discount | Days to Ship | Capacity (W) | Output voltage (Single only) | Rated output current (single only) (A) | Included Function | Representative Standard | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Input Voltage (V) | Rated output current 1 for DC 24 V (A) | Rated output current 2 for DC 12 V (A) | Output voltage variation range (V) | AC Input Voltage Range | AC Input current (Maximum) | DC adjustment range | Effi. | Overload protection | Over voltage protection | Withstand Voltage | Operating temperature | Safety Standard | EMC standards | Other authentication/standards |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 1,952.53 | 1 Piece(s) | Same day | 100 ~ 108 | DC24V | 4.5 | - | UL / CE / TUV / CUL | 97 ~ 159 | 38 ~ 97 | 38 ~ 169 | - | 4.5 | - | - | 85~264VAC; 120~370VDC | Cold start, 65A at 230VAC | -5%~+10% rated output voltage | 88.5% | 105%~135% Constant current limiting, auto-recovery | 115%~145% | I/P-O/P: 3kVAC, I/P-FG: 1.5kVAC, O/P-FG: 0.5kVAC, 1 minute | -40~+60°C | UL60950-1, TUV EN60950-1 approved | EN55022 class B, EN61000-4-2,3,4,5,6,8,11, EN61000-3-2,3, EN61000-6-2 heavy industry level | - | ||
฿ 3,053.74 | 1 Piece(s) | Same day | 200 ~ 201.6 | DC24V | 8.4 | - | UL / CE / TUV / CUL | 98 ~ 199 | 38 ~ 98 | 38 ~ 212 | - | 8.4 | - | - | 85~264VAC; 120~370VDC | Cold start; 70A at 230VAC | ±15% rated output voltage | 88.0% | 105%~135% Constant current limiting, auto-recovery | 115%~145% | I/P-O/P: 3kVAC, I/P-FG: 1.5kVAC, O/P-FG: 0.5kVAC, 1 minute | -40~+70°C | UL60950-1, TUV EN60950-1 approved | EN55022 class B, EN61000-4-2,3,4,5,6,8,11, EN61000-3-2,3, EN61000-6-2 heavy industry level | - | ||
฿ 4,325.44 | 1 Piece(s) | 3 Day(s) | 300 ~ 336 | DC24V | 14 | Fan for cooling | UL / CE / TUV / CUL | 105 ~ 199 | 41 ~ 105 | 41 ~ 216 | - | 14 | - | - | 85~264VAC; 120~370VDC | Cold start, 70A at 230VAC | ±15% rated output voltage | 87.0% | 105%~135% Constant current limiting, auto-recovery | 115%~145% | I/P - O/P: 3kVAC, I/P - FG: 1.5kVAC, O/P - FG: 0.5kVAC, 1 minute | -40~+70°C (refer to output derating curve) | UL60950-1, TUV EN60950-1 approved | EN55022 class B, EN61000-4-2,3,4,5,6,8,11, EN61000-3-2,3, EN61000-6-2 heavy industry level | - | ||
฿ 8,066.67 | 1 Piece(s) | 95 Day(s) | 600 | DC12V | 50 | - | UL / TUV | 170 | 120 | 93 | DC 124 to 370 / AC 88 to 264 | - | - | 10 to 13.2 | 88~264VAC | Cold start, 40A at 230VAC | ±10% rated output voltage | 84% | 105%~135% Constant current limiting,auto-recovery | 115%~140% | I/P - O/P: 3kVAC, I/P - FG: 1.5kVAC, O/P - FG: 0.5kVAC(short for SP-480), 1 minute | -20~+60°C | UL60950-1, TUV EN60950-1 approved; GB4943 approved also for SP-320 (expect for 3.3V/ 5PNC/ 36V) | EN55022 class B, EN61000-4-2,3,4,5,6,8,11, EN61000-3-2,3, EN61000-6-2(SP-480/750), GB9254 (SP-320 only) | EAC/CB | ||
฿ 8,066.67 | 1 Piece(s) | 2 Day(s) | 600 | DC24V | 25 | - | UL / TUV | 170 | 120 | 93 | - | - | - | - | 88~264VAC | Cold start, 40A at 230VAC | ±10% rated output voltage | 86% | 105%~135% Constant current limiting,auto-recovery | 115%~140% | I/P - O/P: 3kVAC, I/P - FG: 1.5kVAC, O/P - FG: 0.5kVAC(short for SP-480), 1 minute | -20~+60°C | UL60950-1, TUV EN60950-1 approved; GB4943 approved also for SP-320 (expect for 3.3V/ 5PNC/ 36V) | EN55022 class B, EN61000-4-2,3,4,5,6,8,11, EN61000-3-2,3, EN61000-6-2(SP-480/750), GB9254 (SP-320 only) | - | ||
฿ 175,540.00 | 1 Piece(s) | 95 Day(s) | 10000 | DC48V | 210 | - | UL / TUV | - | - | - | - | - | - | - | 3Ø 3-wire/196~305VAC or 3Ø 4-wire/Y 340~530VAC | Cold start, 50A (RST-5000); 100A(RST-10000)at 400VAC(3Ø 4-wire/Y) 75A(RST-5000); 150A(RST-10000) at 230VAC(3Ø 3-wire/ ) | -2%~+20% rated output voltage | 91% | 100%~112% constant current limiting, auto-recovery (can adjust to delay shut off) | 125%~140% shut down O/P voltage, re-power on to recover | I/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC | -30~+70°C (refer to output derating curve) | UL60950-1, TUV EN60950-1 approved | EN55022 class A, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 | - |