(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.
Select part number to Order Now/ Add to Cart
[Features]· Universal AC input / Full range· Installed on DIN rail TS35 / 7.5 or 15· Protections: Short circuit / Overload / Overvoltage· No load power consumption <0.75 W (<1 W for MDR-100)· LED indicator for power on· NEC class 2 / LPS compliant (selected models)· Built-in active PFC and over temp. protection (MDR-100)· DC OK signal output (MDR-10/20)· DC OK relay contact (MDR-40/60/100)· Cooling by free air convection· 100% full load burn-in test
Part Number |
---|
MDR-10-5 |
MDR-10-12 |
MDR-10-24 |
MDR-20-5 |
MDR-20-12 |
MDR-20-24 |
MDR-40-12 |
MDR-40-24 |
MDR-60-12 |
MDR-60-24 |
MDR-100-12 |
MDR-100-24 |
SDR-75-12 |
SDR-240-24 |
SDR-480-24 |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | RoHS | Capacity (W) | Output voltage (Single only) | Rated output current (single only) (A) | Input/output terminal shape | Representative Standard | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Rated output current 1 for DC 24 V (A) | Rated output current 2 for DC 12 V (A) | Rated output current 3 for DC 5 V (A) | AC Input Voltage Range | AC Input current (Maximum) | DC adjustment range | Effi. | Overload protection | Over voltage protection | Withstand Voltage | Operating temperature | Safety Standard | EMC standards |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 568.08 ฿ 486.96 | SWITCHING POWER SUPPLY | 1 Piece(s) | 65 Day(s) | - | 10 | DC5V | 2 | European format | CE / UL / CUL / TUV | 22.5 ~ 90 | 22.5 ~ 90 | 100 | - | - | 2 | 85~264VAC; 120~370VDC | Cold start, 35A at 115VAC, 70A at 230VAC | Fixed | 77% | >105% hiccup mode, auto-recovery | 115%~135% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 652.63 | SWITCHING POWER SUPPLY | 1 Piece(s) | 3 Day(s) | - | 10 | DC12V | 0.84 | European format | CE / UL / CUL / TUV | 22.5 ~ 90 | 22.5 ~ 90 | 100 | - | 0.84 | - | 85~264VAC; 120~370VDC | Cold start, 35A at 115VAC, 70A at 230VAC | Fixed | 81% | >105% hiccup mode, auto-recovery | 115%~135% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 568.08 ฿ 486.90 | SWITCHING POWER SUPPLY | 1 Piece(s) | Same day | - | 10 | DC24V | 0.42 | European format | CE / UL / CUL / TUV | 22.5 ~ 90 | 22.5 ~ 90 | 100 | 0.42 | - | - | 85~264VAC; 120~370VDC | Cold start, 35A at 115VAC, 70A at 230VAC | Fixed | 84% | >105% hiccup mode, auto-recovery | 115%~135% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 646.00 ฿ 553.69 | SWITCHING POWER SUPPLY | 1 Piece(s) | 2 Day(s) | - | 20 | DC5V | 3 | European format | CE / UL / CUL / TUV | 22.5 ~ 90 | 22.5 ~ 90 | 100 | - | - | 3 | 85~264VAC; 120~370VDC | Cold start, 20A at 115VAC, 40A at 230VAC | ±10% rated output voltage | 76% | 105%~160% constant current limiting, auto-recovery | 115%~135% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 646.00 ฿ 553.75 | SWITCHING POWER SUPPLY | 1 Piece(s) | Same day | - | 20 | DC12V | 1.67 | European format | CE / UL / CUL / TUV | 22.5 ~ 90 | 22.5 ~ 90 | 100 | - | 1.67 | - | 85~264VAC; 120~370VDC | Cold start, 20A at 115VAC, 40A at 230VAC | ±10% rated output voltage | 80% | 105%~160% constant current limiting, auto-recovery | 115%~135% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 646.00 ฿ 553.75 | SWITCHING POWER SUPPLY | 1 Piece(s) | 65 Day(s) | - | 20 ~ 24 | DC24V | 1 | European format | CE / UL / CUL / TUV | 22.5 ~ 90 | 22.5 ~ 90 | 100 | 1 | - | - | 85~264VAC; 120~370VDC | Cold start, 20A at 115VAC, 40A at 230VAC | ±10% rated output voltage | 84% | 105%~160% constant current limiting, auto-recovery | 115%~135% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 855.67 ฿ 733.39 | SWITCHING POWER SUPPLY | 1 Piece(s) | 65 Day(s) | - | 40 | DC12V | 3.33 | European format | CE / UL / CUL / TUV | 40 ~ 90 | 40 ~ 90 | 100 | - | 3.33 | - | 85~264VAC; 120~370VDC | Cold start, 30A at 115VAC, 60A at 230VAC | 0~+20% rated output voltage | 86% | 105%~150% constant current limiting, auto-recovery | 125%~150% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 855.67 ฿ 733.39 | SWITCHING POWER SUPPLY | 1 Piece(s) | Same day | - | 40 ~ 40.8 | DC24V | 1.7 | European format | CE / UL / CUL / TUV | 40 ~ 90 | 40 ~ 90 | 100 | 1.7 | - | - | 85~264VAC; 120~370VDC | Cold start, 30A at 115VAC, 60A at 230VAC | 0~+20% rated output voltage | 88% | 105%~150% constant current limiting, auto-recovery | 125%~150% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 935.00 ฿ 801.39 | SWITCHING POWER SUPPLY | 1 Piece(s) | Same day | - | 60 | DC12V | 5 | European format | CE / UL / CUL / TUV | 40 ~ 90 | 40 ~ 90 | 100 | - | 5 | - | 85~264VAC; 120~370VDC | Cold start, 30A at 115VAC, 60A at 230VAC | 0~+20% rated output voltage | 86% | 105%~150% constant current limiting, auto-recovery | 125%~150% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 935.00 ฿ 801.39 | SWITCHING POWER SUPPLY | 1 Piece(s) | 65 Day(s) | 10 | 60 | DC24V | 2.5 | - | UL / TUV | 40 | 90 | 100 | - | - | - | 85~264VAC; 120~370VDC | Cold start, 30A at 115VAC, 60A at 230VAC | 0~+20% rated output voltage | 88% | 105%~150% constant current limiting, auto-recovery | 125%~150% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 1,615.00 ฿ 1,384.22 | SWITCHING POWER SUPPLY | 1 Piece(s) | 65 Day(s) | - | 100 | DC12V | 7.5 | European format | CE / UL / CUL / TUV | 55 ~ 90 | 55 ~ 90 | 100 | - | 7.5 | - | 85~264VAC; 120~370VDC | Cold start, 30A at 115VAC, 60A at 230VAC | 0~+20% rated output voltage | 83% | 105%~150% constant current limiting, auto-recovery | 125%~150% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -10~+60°C | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 2,051.61 | SWITCHING POWER SUPPLY | 1 Piece(s) | Same day | - | 96 ~ 100 | DC24V | 4 | European format | CE / UL / CUL / TUV | 55 ~ 90 | 55 ~ 90 | 100 | 4 | - | - | 85~264VAC; 120~370VDC | Cold start, 30A at 115VAC, 60A at 230VAC | 0~+20% rated output voltage | 86% | 105%~150% constant current limiting, auto-recovery | 125%~150% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -10~+60°C | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 1,598.00 ฿ 1,369.65 | POWER SUPPLY | 1 Piece(s) | 65 Day(s) | - | 75 | DC12V | 6.3 | - | UL / TUV | 32 | 125.2 | 102 | - | - | - | 88~264VAC; 124~370VDC | Cold start, 50A at 230VAC | 12V: 12~14V (only for SDR-75/120), 24V: 24~28V, 48V: 48~55V | 88.5% | Normally works within 110%~150% rated output power for 3 seconds and then shut down output voltage with auto-recovery (re-power on to recover for SDR-75) , >150% rated power or short circuit, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds | 14~17V for 12V model(SDR-75/120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage, re-power on to recover | I/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC (except for SDR-75) | -30~+70°C | UL508, TUV EN60950-1, GL (SDR-120/240/480) approved | EN55011(SDR-120/240/480), EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3; SEMI (SDR-75/120/240/480), GL (SDR-120/240/480) | ||
฿ 4,523.42 ฿ 3,877.02 | SWITCHING POWER SUPPLY | 1 Piece(s) | Same day | 10 | 240 | DC24V | 10 | - | UL / TUV | 63 | 125.2 | 113.5 | - | - | - | 88~264VAC; 124~370VDC | Cold start, 65A at 230VAC | 12V: 12~14V (only for SDR-75/120), 24V: 24~28V, 48V: 48~55V | 94% | Normally works within 110%~150% rated output power for 3 seconds and then shut down output voltage with auto-recovery (re-power on to recover for SDR-75) , >150% rated power or short circuit, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds | 14~17V for 12V model(SDR-75/120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage with auto-recovery, or re-power on to recover | I/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC (except for SDR-75) | -25~+70°C (refer to output derating curve) | UL508, TUV EN60950-1, GL (SDR-120/240/480) approved | EN55011(SDR-120/240/480), EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3; SEMI (SDR-75/120/240/480), GL (SDR-120/240/480) | ||
฿ 8,228.07 | SWITCHING POWER SUPPLY | 1 Piece(s) | 3 Day(s) | - | 480 | DC24V | 20 | European format | CE / UL / CUL / TUV | 85.5 ~ 125.2 | 85.5 ~ 125.2 | 128.5 | 20 | - | - | 90~264VAC; 127~370VDC | Cold start, 80A at 230VAC | 12V: 12~14V (only for SDR-75/120), 24V: 24~28V, 48V: 48~55V | 94% | Normally works within 110%~150% rated output power for 3 seconds and then shut down output voltage with auto-recovery (re-power on to recover for SDR-75) , >150% rated power or short circuit, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds | 14~17V for 12V model(SDR-75/120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage with auto-recovery, or re-power on to recover | I/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC (except for SDR-75) | -25~+70°C (refer to output derating curve) | UL508, TUV EN60950-1, GL (SDR-120/240/480) approved | EN55011(SDR-120/240/480), EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3; SEMI (SDR-75/120/240/480), GL (SDR-120/240/480) |
Loading...
Shape | DIN rail direct attachment | Single/multi | Single | Input Voltage | AC/DC |
---|
How can we improve?
How can we improve?