(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.
Select part number to Order Now/ Add to Cart
Calendar timer conforming to the CE mark that allows for simple control of the time of day.
[Features]
· Days of the week can be selected for operation (however, can set only one pattern of operation days and specified days).
· Remarkably simple handling of holidays, etc., with the holiday function and easily supports changes to the schedule with semi-automatic operation.
· Simplified program checks with the test mode function.
· Product lineup includes embedded and surface mount along with JIS-standardized dimension types.
[Applications]
· Optimal when control equipment is required for switching the output signal at the preset time after the start signal is input.
· Can be used for all kinds of industrial equipment.
24-step ON/OFF time schedule settings
Embedded mounted type (mounting adapter Y92F-30 included)
Series H5F-A/-B
Surface mounted type
Series H5F-FA/-FB
Conventional size type
Series H5F-KA/-KB (vertical direction)
Series H5F-KAL (horizontal dimension)
Mounting Method | Embedded Mounting | Surface Mounting | Surface / DIN Rail Mounting (Conventional Type) |
---|---|---|---|
Vertical Direction | |||
Japanese Specification Format | Series H5F-A | Series H5F-FA | Series H5F-KA |
English Specification Format | Series H5F-B |
Model Configuration
Power Supply Voltage | 100 to 240 V AC, 50/60 Hz (Common) |
---|---|
Allowable Voltage Range | 85 to 110% of power supply voltage |
Power Consumption | Approx. 2.4 VA (At 264 V AC) |
Control Output | Contact 1a 250 V AC, 15 A (resistive load) 24 V DC, 10 A (resistive load) Minimum applied load 5 V DC, 100 mA (P level, reference value) |
Operating Temperature Range | −10 to +55°C (No Freezing) |
Storage Temperature Range | −25 to +65°C (No Freezing) |
Ambient Operating Humidity | 35 to 85% |
Case Exterior | Light Gray (Munsell 5Y7/1) |
Rating
Variations In Operating Time | (±0.01% ±0.05 s) or less*1 ±0.01% is the value for the set time interval. | |
---|---|---|
Set Error | ||
Voltage Effect | ||
Temperature Effect | ||
Electromagnetic Interference (According To EN61326-1) | ||
Time Accuracy | ±15 s/month (25°C) | |
Compensation Time For Power Outage | Continuous 5 years or more (25°C), 10 years or more (25°C, power failure ratio 50% or less)*2 (With lithium battery) | |
Insulation Resistance | 100 MΩ or more (between conductive part terminal and exposed non-charging metal part, between operation power supply circuit and control output, between discontinuous contacts) | |
Withstand Voltage | 2,000 V AC, 50/60 Hz, 1 min (between conductive part terminal and exposed non-charging metal part, between operation power supply circuit and control output) 1,000 V AC, 50/60 Hz, 1 min (between discontinuous contacts) | |
Noise Resistance | Between power supply terminals: ±1.5 kV Square-wave noise by noise simulator (pulse width 100 ns/1 μs, rise 1 ns) | |
Vibration | Endurance | 10 to 55 Hz, half amplitude 0.375 mm, 3 directions, 4 cycles each (8 min/cycle) |
Malfunction | 10 to 55 Hz, half amplitude 0.25mm, 3 directions, 10 min each | |
Shock | Endurance | 300 m/s2, 3 axes each direction, 3 times each |
Malfunction | 100 m/s2, 3 axes each direction, 3 times each | |
Life | Mechanical | 100,000 operations or more (20°C) |
Electrical | 50,000 operations or more (resistive load, 250 V AC, 15 A) 50,000 operations or more (motor load, 250 V AC, 1 HP) 50,000 operations or more (inductive load, 250 V AC, 10 A, cosφ = 0.7) 50,000 operations or more (lamp load, 100 V AC, 100 W) 10,000 operations or more (lamp load, 100 V AC, 300 W) (+20°C) | |
Mass | Approx. 115 g (Series H5F-A), Approx. 160 g (Series H5F-KA), Approx. 130 g (Series H5F-FA) |
Performance
*1. Total error including variations in operating time, set errors, and the effects of voltage and temperature are within (±0.01% ±0.05 s)
*2. Cumulative time of power failure
Safety Standards | cULus (listing): UL508/CSA C22.2 No. 14 EN61010-1 (IEC61010-1): Pollution Degree 2 / Overvoltage Category II A300 PILOT DUTY 1/3HP 120 VAC VDE0106/part10 Product Safety of Electrical Appliance and Material |
---|---|
EMC | (EMI) EN61326-1* Radiation interference field strength EN55011 Group 1 Class A Noise terminal voltage EN55011 Group 1 Class A (EMS) EN61326-1* Electrostatic discharge immunity EN61000-4-2: 4 kV direct, 8 kV atmospheric Field strength immunity EN61000-4-3: 10 V/mAM modulation (80 MHz to 1 GHz, 1.4 to 2 GHz) Conductive noise immunity EN61000-4-6: 10 V (0.15 to 80 MHz) Burst noise immunity EN61000-4-4: 2 kV power supply line, 1 kV output line Surge immunity EN61000-4-5: 1 kV between lines (power supply line, output line), 2 kV between grounds (power supply line, output line) Voltage dip / interruption immunity EN61000-4-11: 0.5 cycles, 100% (rated voltage) Magnetic field strength immunity EN61000-4-8: 30 A/m |
Applicable standards
*Industrial electromagnetic environment (EN/IEC61326-1 Table 2)
Global support
Conforms to the CE mark, all models conform to finger protection standards, so they can be securely used overseas.
Extensive applications
Supports 4 different mounting methods and 24-step ON/OFF operation for a variety of applications.
Usage example
Easily deal with sudden schedule changes using the "holiday function" and "semiautomatic operation."
Part Number |
---|
H5F-A |
H5F-B |
H5F-FA |
H5F-KA |
H5F-KB |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | Type | Mounting Method | Time specifications (s) | Power Supply Voltage | Dimension vertical (mm) | Dimension width (mm) | Dimension depth (mm) | Rated power supply voltage (V) | Time ranges = N | Contact Configuration | Weight (g) | Operating voltage range | Power consumption | Control outputs | External connections | Terminal style | Terminal screw tightening torque (N · m) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 7,188.00 ฿ 4,887.84 | TIMER/CALENDER | 1 Piece(s) | Same day | [Other] Time switch | Panel | 24 h × 7 day (1-min units) | AC-dedicated | 48 | 48 | 63.7 | AC 100–240 | - | 1a | - | - | - | - | - | - | - | ||
฿ 7,188.00 ฿ 3,895.90 | TIMER/CALENDER | 1 Piece(s) | Same day | [Other] Time switch | Panel | 24 h × 7 day (1-min units) | AC-dedicated | 48 | 48 | 63.7 | AC 100–240 | - | 1a | - | - | - | - | - | - | - | ||
฿ 7,188.00 ฿ 3,483.30 | TIMER/CALENDER | 1 Piece(s) | Same day | [Other] Time switch | [Other] Surface mounting | 24 h × 7 day (1-min units) | AC-dedicated | 92 | 50 | 42.1 | AC 100–240 | - | 1a | - | - | - | - | - | - | - | ||
฿ 7,630.00 ฿ 6,104.76 | TIMER/CALENDER | 1 Piece(s) | 45 Day(s) | [Other] Time switch | [Other] DIN rail/Surface mount | 24 h × 7 day (1-min units) | AC-dedicated | 101.2 | 50.5 | 60 | AC 100–240 | - | 1a | - | - | - | - | - | - | - | ||
฿ 6,112.00 ฿ 4,888.99 | TIMER | 1 Piece(s) | Same day | [Timer] Timer | [Other] Surface mounting | - | 100 to 240V AC | - | - | - | - | 24 hr x 7 d | - | 115 | 85% to 110% of rated supply voltage | Approx. 2.4 VA at 264 VAC | Contact output: SPST-NO, 15 A at 250 VAC, resistive load, 10 A at 24 VDC, resistive load Minimum applied load: 100 mA at 5 VDC (failure level: P, reference value)NEMA A300 Pilot Duty, 1/3 HP at 120 VAC | Screw terminals (M3.5 screw) | Screw terminals (M3.5 screw) | 0.98 to 1.17 |
Loading...
Display method | Liquid Crystal |
---|
How can we improve?
How can we improve?