Digital Daily Time Switch H5F

Brand :
OMRON

Caution

    Product Description

    Calendar timer conforming to the CE mark that allows for simple control of the time of day.
    [Features]
    · Days of the week can be selected for operation (however, can set only one pattern of operation days and specified days).
    · Remarkably simple handling of holidays, etc., with the holiday function and easily supports changes to the schedule with semi-automatic operation.
    · Simplified program checks with the test mode function.
    · Product lineup includes embedded and surface mount along with JIS-standardized dimension types.
    [Applications]
    · Optimal when control equipment is required for switching the output signal at the preset time after the start signal is input.
    · Can be used for all kinds of industrial equipment.

    Embedded And Surface Mounted Types Available In Conventional Sizes

    Digital Daily Timer Switch H5F: related image

    24-step ON/OFF time schedule settings

    Digital Daily Timer Switch H5F Outline Drawing And Dimensions

    Digital Daily Timer Switch H5F: related image

    Embedded mounted type (mounting adapter Y92F-30 included)
    Series H5F-A/-B

    Digital Daily Timer Switch H5F: related image

    Surface mounted type
    Series H5F-FA/-FB

    Digital Daily Timer Switch H5F: related image

    Conventional size type
    Series H5F-KA/-KB (vertical direction)
    Series H5F-KAL (horizontal dimension)

    H5F Specifications

    Mounting MethodEmbedded MountingSurface MountingSurface / DIN Rail Mounting (Conventional Type)
    Vertical Direction
    Japanese Specification FormatSeries H5F-ASeries H5F-FASeries H5F-KA
    English Specification FormatSeries H5F-B

    Model Configuration

    Power Supply Voltage100 to 240 V AC, 50/60 Hz (Common)
    Allowable Voltage Range85 to 110% of power supply voltage
    Power ConsumptionApprox. 2.4 VA (At 264 V AC)
    Control OutputContact 1a 250 V AC, 15 A (resistive load)
    24 V DC, 10 A (resistive load)
    Minimum applied load 5 V DC, 100 mA (P level, reference value)
    Operating Temperature Range−10 to +55°C (No Freezing)
    Storage Temperature Range−25 to +65°C (No Freezing)
    Ambient Operating Humidity35 to 85%
    Case ExteriorLight Gray (Munsell 5Y7/1)

    Rating

    Variations In Operating Time(±0.01% ±0.05 s) or less*1
    ±0.01% is the value for the set time interval.
    Set Error
    Voltage Effect
    Temperature Effect
    Electromagnetic Interference (According To EN61326-1)
    Time Accuracy±15 s/month (25°C)
    Compensation Time For Power OutageContinuous 5 years or more (25°C), 10 years or more (25°C, power failure ratio 50% or less)*2
    (With lithium battery)
    Insulation Resistance100 MΩ or more (between conductive part terminal and exposed non-charging metal part, between operation power supply circuit and control output, between discontinuous contacts)
    Withstand Voltage2,000 V AC, 50/60 Hz, 1 min (between conductive part terminal and exposed non-charging metal part, between operation power supply circuit and control output)
    1,000 V AC, 50/60 Hz, 1 min (between discontinuous contacts)
    Noise ResistanceBetween power supply terminals: ±1.5 kV
    Square-wave noise by noise simulator (pulse width 100 ns/1 μs, rise 1 ns)
    VibrationEndurance10 to 55 Hz, half amplitude 0.375 mm, 3 directions, 4 cycles each (8 min/cycle)
    Malfunction10 to 55 Hz, half amplitude 0.25mm, 3 directions, 10 min each
    ShockEndurance300 m/s2, 3 axes each direction, 3 times each
    Malfunction100 m/s2, 3 axes each direction, 3 times each
    LifeMechanical100,000 operations or more (20°C)
    Electrical50,000 operations or more (resistive load, 250 V AC, 15 A)
    50,000 operations or more (motor load, 250 V AC, 1 HP)
    50,000 operations or more (inductive load, 250 V AC, 10 A, cosφ = 0.7)
    50,000 operations or more (lamp load, 100 V AC, 100 W)
    10,000 operations or more (lamp load, 100 V AC, 300 W) (+20°C)
    MassApprox. 115 g (Series H5F-A), Approx. 160 g (Series H5F-KA), Approx. 130 g (Series H5F-FA)

    Performance
    *1. Total error including variations in operating time, set errors, and the effects of voltage and temperature are within (±0.01% ±0.05 s)
    *2. Cumulative time of power failure

    Safety StandardscULus (listing): UL508/CSA C22.2 No. 14
    EN61010-1 (IEC61010-1): Pollution Degree 2 / Overvoltage Category II
    A300 PILOT DUTY
    1/3HP 120 VAC
    VDE0106/part10
    Product Safety of Electrical Appliance and Material
    EMC(EMI) EN61326-1*
    Radiation interference field strength EN55011 Group 1 Class A
    Noise terminal voltage EN55011 Group 1 Class A
    (EMS) EN61326-1*
    Electrostatic discharge immunity EN61000-4-2: 4 kV direct, 8 kV atmospheric
    Field strength immunity EN61000-4-3: 10 V/mAM modulation (80 MHz to 1 GHz, 1.4 to 2 GHz)
    Conductive noise immunity EN61000-4-6: 10 V (0.15 to 80 MHz)
    Burst noise immunity EN61000-4-4: 2 kV power supply line, 1 kV output line
    Surge immunity EN61000-4-5: 1 kV between lines (power supply line, output line), 2 kV between grounds (power supply line, output line)
    Voltage dip / interruption immunity EN61000-4-11: 0.5 cycles, 100% (rated voltage)
    Magnetic field strength immunity EN61000-4-8: 30 A/m

    Applicable standards
    *Industrial electromagnetic environment (EN/IEC61326-1 Table 2)

    Features of this product

    Digital Daily Timer Switch H5F: related image

    Global support
    Conforms to the CE mark, all models conform to finger protection standards, so they can be securely used overseas.

    Digital Daily Timer Switch H5F: related image

    Extensive applications
    Supports 4 different mounting methods and 24-step ON/OFF operation for a variety of applications.

    Digital Daily Timer Switch H5F: related image

    Usage example

    Easily deal with sudden schedule changes using the "holiday function" and "semiautomatic operation."

    Viewed Products
    Recently Viewed Products
    My Components
    My Components
    0
    Cart
    Cart
    Economy Series
    MRO Product

    Chat with MISUMI

    Chat service is available for any inquiry to MISUMI

    Service hours

    9:00 - 18:00 (Mon-Sat)

    For out of service hours, you can leave a message to us.
    We will reply to your inquiries on the next business day.
    (except Sundays and public holidays).

    Noted for use

    Chat service is for Corporate customers and limited for Thai language.

    Request for Quotation and Place Order is not available on Chat.

    Start chat