FTB Series, 3-Phase Input Type (2-Stage Filter) (FTB-100-324-HS)

EMI THUNDER MEASURES PARTS

FTB Series, 3-Phase Input Type (2-Stage Filter) (FTB-100-324-HS)
You can add up to 6 items per a category to the compare list.

Part Number :
  • Qty :
  • Days to Ship :
    ---
  • Total Price :
    ---

Select part number to Order Now/ Add to Cart

Product Description

Excellent damping characteristics. Space-saving design. Recommended filter for Mitsubishi Electric Corporation general-purpose AC servo.
[Features]
· Book type (small installation area).
· High attenuation of 150 kHz-1 MHz low frequency band (2-stage filter).
· Ultra-high attenuation type -355-L for European power supply (neutral grounding) with select able leakage current.

FTB Series, 3-Phase Input Type (2-Stage Filter)

FTB Series, 3-Phase Input Type (2-Stage Filter)

Product picture of FTB Series (80A / 100A / 150A)

FTB Series, 3-Phase Input Type (2-Stage Filter)
1. Model name
2. Rated current
3. Line to ground capacitor code (see table below)
4. Option
H: Ultra high-attenuation type ("355" is not applied)
S: Hexagon socket head cap screw (Standard type is Hexagon head screw)
L: Ultra high-attenuation type for EU
CodeLeakage Current *2
Upper Row : △-connection
Lower Row : Y-connection
Line to Ground Capacitor CY1
(Nominal Value)
Line to Ground Capacitor CY2
(Nominal Value)
2031.0mA/2.0mA max
0.1mA/0.2mA max
10,000pF10,000pF
6632.5mA/5.0mA max
0.35mA/0.7mA max
33,000pF33,000pF
32412mA/24mA max
1.5mA/3.0mA max
220,000pF100,000pF
355 *1330mA/515mA max
40mA/80mA max
220,000pF3,300,000pF

*When the line to ground capacitor code is different, the attenuation characteristic is different.
*1 "355" is applied only to "L" type.
*2 Input 250/500V 60Hz
(Only D-connection of "355" is 250/400V 60Hz)

Features

Book type (Space-saving type)
- 2-stage filter High-attenuation (150kHz - 1MHz)
- Selectable leakage current value,Ultra high-attenuation type
"-355-L" for EU (Y type with neutral earth system)

Specifications

No.ItemsFTB-80-663FTB-100-663FTB-150-663
1Rated Voltage (V)AC Three Phase 500 (voltage range:528 max) 50/60Hz
2Rated Current (A)80100150
3Test Voltage (Terminal-Mounting Plate)2,500 VAC (Cutoff Current = 100mA), 1minute at room temperature and humidity
4Isolation Resistance (Terminal-Mounting Plate)500 VDC 100MW min at room temperature and humidity
5Leakage Current 250/500V 60Hz2.5mA/5.0mA max
6DC Resistance10mΩ max8mΩ max6mΩ max
7Safety Agency Approval Temperatures-25 to +85 °C (Refer to Derating Curve)
8Operating Temperature-40 to +85 °C (Refer to Derating Curve)
9Operating Humidity20 to 95%RH (Non condensing)
10Storage Temperature/Humidity-40 to +85 °C/20 to 95%RH (Non condensing)
11Vibration10 to 55Hz, 19.6m/s2 (2G), 3min.
Period, 1hour each X, Y and Z axis
12 Impact
12Impact196.1m/s2 (20G), 11ms. Once each X, Y and Z axis
13Safety Agency ApprovalsUL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil3-1, ENEC
14Case Size (Without Projection)100 x 170 x 350 mm (W x H x D)100 x 210 x 400 mm (W x H x D)
(3.94X6.69X13.78 inches)(3.94X8.27X15.75 inches)
15Weight5.3kg max7.8kg max

Drawing

Circuit Diagram

FTB Series, 3-Phase Input Type (2-Stage Filter)

Derating Curve

FTB Series, 3-Phase Input Type (2-Stage Filter)

External View

FTB Series, 3-Phase Input Type (2-Stage Filter)

External view of FTB-50-/FTB-100-

FTB Series, 3-Phase Input Type (2-Stage Filter)

External view of FTB-150-

Part Number
FTB-100-324-HS
Part NumberPriceNameMinimum Order Qty.Volume DiscountDays to ShipRoHSRated Current
(A)
D
(mm)
H
(mm)
Leak current value
(mA max)
Special Notes

฿ 32,444.38

EMI THUNDER MEASURES PARTS 1 Piece(s) 13 Day(s) 1010035017024(500V60Hz)High permeability choke coil part (ultra-low-pass, high-attenuation) / Bolt with hex socket head

Loading...

  1. 1
 

Basic Information

Input Type Three-Phase Mounting Method Fasten With Screws Wiring Method Screw Fastening
Safety standards UL / CUL / CSA W(mm) 100 Representative standards (VDE) Corresponds To
Representative standards (ENEC) Corresponds To 150 kHz to 1 MHz, high attenuation Corresponds To