ø30 XN Series, Emergency Stop Switch

Caution
Product Description
ø30 XN series, emergency stop switch
[Features]
· A ø30 emergency stop switch that comes in a variety of types.
· The padlock type lets you lock it in place, while the flash-bezel type has an attractive design.
· Large number of variations: padlock-supporting type, flash-bezel type, ø60 extra-large type, illuminated type, linked illumination type, and more.
· Superior safety provided by the same safe-breaking action and safety-potential construction as seen in the ø166 XA/ø22 XW series.
· The switches naturally conform to all requirements emergency stop switches need, including a direct-opening feature and safety lock.
· Panel depth is only 47.7 mm, even with 4 contacts and illumination (flash bezel: 60.4 mm, padlock: 61.4 mm).
· The padlock-supporting type allows you to padlock the switch into the lock (main contact off) position.
· Use with a supporting bracket (HASP) to lock on up to 20 padlocks (total weight: 1,500 g).
· The locking section is made of solid diecast aluminum.
· Gold-plated silver contacts.
· 2 types of red colors provided for the buttons on non-illuminated types.
· * Dark red (R): Munsell code 5R4/12 (approximate).
· Bright red (RH): Munsell code 7.5R4.5/14 (approximate).
· Approved for the UL emergency stop category.
Product Information of IDEC Emergency Stop Switches / Safety Switches
- IDEC emergency stop switch for space saving and safety
- Space-saving design:Approximately 30% shorter in depth than conventional products, making it more compact
- Safety design:The main contact will be turned off even if the switch is damaged by impact (patented by the manufacturer)
Space Saving of IDEC Emergency Stop Switches / Safety Switches
The depth has been shortened by approximately 30% compared to conventional products, resulting in space saving.

Safety of IDEC Emergency Stop Switches / Safety Switches
- Safe Potential Structure
- IDEC's unique safety structure keeps the main contacts OFF even if the switch is damaged by excessive force or impact (IDEC patented)

Safety standards of IDEC Emergency Stop Switches / Safety Switches

Direct Opening Function of IDEC Emergency Stop Switches / Safety Switches
Even if the contacts are welded, pressing the button directly separates the contacts, reliably breaking the circuit
(Complies with IEC60947-5-5: 5.2, IEC60947-5-1 Annex K).

Safety Lock Mechanism of IDEC Emergency Stop Switches / Safety Switches
To prevent unexpected sudden start-up, the contacts open at the same time as the actuator latches
(IEC60947-5-5: Section 6.2) .

Compliant with Various Safety Standards of IDEC Emergency Stop Switches / Safety Switches
UL, c-UL certified products and EN standard compliant products, UL emergency stop category certified products
UL508, CSA C22.2 No.14, IEC60947-5-5, UL991, NFPA79, EN60947-5-1, EN60947-5-5, GB14048.5