Wear Resistant Tubing TUZ Series

Caution
- For specifications and details, please refer to the catalog.
- Product pictures are representations.
Product Description
Wear Resistant Tubing TUZ Series
Polyurethane Tubes are used in various industries especially in penumatic system. They offer a wide variety of sizes to choose from.
[Feature]
● Outer Diameter (mm.) : 4, 6, 8, 10, 12 and 16
● Inner Diameter (mm.) : 2, 2.5, 4, 5, 6.5, 8 and 10
● Length (m.) : 20 and 100
● Maximum operating pressure (MPa) : at 20°C = 0.8
● Operating Temperature Range (℃) : Air -20 to +60°C, Water: 0 to 40°C (No freezing)
● Material : Special Polyurethane
● Color : Black, Milky White, Red, Blue, Yellow and Green
[Application]
This Polyurethane Tube is used to connect with pneumatic equipments such as cylinders, fitting, directional control valve and so on.
Features Of Wear Resistant Tube TUZ Series

How to measure the minimum bending radius
Bend the tube into a U shape at a temperature of 20°C. Fix one end and close the loop gradually. Measure 2R when the tube breaks or is crushed.
Series List
| Nominal | TUZ0425 | TUZ0604 | TUZ1065 | TUZ1208 |
|---|---|---|---|---|
| Outer diameter (mm) | 4 | 6 | 10 | 12 |
| Inner diameter (mm) | 2.5 | 4 | 6.5 | 8 |
Specifications
| Fluid | Air, water | ||||
|---|---|---|---|---|---|
| Applicable fittings | One-touch fittings KQ2 Series Insert fittings KF Series Stainless steel 316 Insert fittings KFG2 Series Miniature fittings M, MS Series (Hose-nipple type) | ||||
| Maximum operating pressure (MPa) | 20°C | 0.8 | |||
| 40°C | 0.6 | ||||
| 60°C | 0.4 | ||||
| Minimum bending radius mm | 10 | 15 | 27 | 35 | |
| Operating temperature | -20 to +60°C, Water: 0 to 40°C (No freezing) | ||||
| Material | Special polyurethane | ||||
- 1. The value of the minimum bending radius is measured at a temperature of 20°C as shown above. The minimum bending radius assumes static piping. If the tube is used in a moving part, provide extra length to the tube. Check the bending radius recommended by the flexible protection tube manufacturer if the tube is used in a flexible protection tube.
- 2. Applicable to general industrial water. Please consult with SMC if using other kinds of fluid. Surge pressure must be under the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to fittings and tubes.
- 3. Abnormal temperature rise caused by adiabatic compression may result in the tube bursting.
Maximum operating pressure

Maximum Operating Pressure

Tube Dimensions Inside the Flexible Protection Tube
(Unit: mm)
Test Conditions
| Test tube | TUZ0604, TU0604 |
|---|---|
| Quantity of tube tested | 5 pcs. for each |
| Operating speed | 1,500 mm/sec |
| Operating frequency | 90 c.p.m |
| Operating stroke L | 500 mm |
| Bending radius R | 28 mm |
| Material of flexible protection tube | Special engineering plastic |
| Zip tie | Not used |
Test Results
Model: TUZ0604, Maximum abrasion after 10 million cycles (mm): 0.16
- As this test was an acceleration test, the tube bending radius was out of the flexible protection tube manufacturer's allowable range.
- When the flexible protection tube is used in the actual application, check the manufacturer's catalog specifications.
- The values in the table above are representative values, and are not guaranteed.