Tactile Switch [D5B]

Caution
Product Description
A multi-use touch switch for detecting objects in multiple directions.
[Features]
· Uses a slow-action switching mechanism.
· Gold-plated contacts that provide high contact reliability with micro loads.
· Allows for direct input to microcomputers, programmable microcontrollers, etc.
· Three small outer diameter variations available: M5, M8 and M10.
· Uses a panel mounting design for easier installation.
Dimensional Drawing of OMRON Limit Switch
Limit Switch M5 Type

Limit Switch D5B-501□

Limit Switch D5B-502□

Limit Switch D5B-551□
Limit Switch M8 Type

Limit Switch D5B-801□

Limit Switch D5B-802□

Limit Switch D5B-851□
Limit Switch M10 Type

Limit Switch D5B-101□

Limit Switch D5B-151□

Limit Switch D5B-102□

Limit Switch D5B-153□
Note 1. In the above external dimensions of each model, the dimensional tolerance of Limit Switch parts not specified is ±0.4 mm.
Note 2. The screw part of the case has a special screw dimension (pitch 0.5 mm). It cannot be installed with standard tapping, so please install with the included nut.
Specification Table of OMRON Limit Switch
Limit Switch Ratings/Performance
| Electrical Rating | DC5V 1mA to DC30V 30mA (resistive load) | |
|---|---|---|
| Protective structure | IP67 | |
| Durability *1 | Mechanical | Over 10 million times |
| Limit Switch Electrical | Over 5 million times (DC30V 30mA resistive load) | |
| Allowable Operating Speed | 5 to 500 mm/s | |
| Allowable operating frequency | Mechanical | 120 times/min |
| Electrical | 60 times/min | |
| Insulation resistance | Between each terminal and non-current-carrying metal part: 100MΩ (DC250V megger) | |
| Contact Resistance | With 1m cord: 700mΩ or less (initial value) With 3m cord: 1.9Ω or less (initial value) With 5m cord: 3.1Ω or less (initial value) | |
| Withstand voltage (50/60Hz 1min) | Between same-polarity terminals | AC250V (TTP) |
| Between each terminal and non-current-carrying metal parts | AC1,000V (600V for M5 type) | |
| vibration | malfunction | 10 to 55Hz, double amplitude 1.5mm *2 |
| impact | Durability | Up to 1,000m/s2 |
| malfunction | Maximum 300m/s2* 3 | |
| Ambient temperature | -10 to +70℃ (but do not freeze) | |
| Ambient humidity | 35~95% RH | |
| Actuator Strength | 14.7N *4 | |
| mass | Switch body | Approx. 14g (M5), approx. 20g (M8), approx. 21g (M10) |
| cable | Approximately 10g/m | |
Note: The above values are initial values.
*1. Durability values are for ambient Limit Switch of +5 to +35°C and humidity of 40 to 70% RH.
*2. Wire spring type: 16.7Hz, double amplitude of 1mm
*3. Wire spring type: maximum 50m/s2*
4. Wire spring type excluded.
| Type | M5 | M8 | M10 | ||
|---|---|---|---|---|---|
| Actuator | Cable length (m) | Model | Model | ||
Hemispheric actuator![]() | 1 | D5B-5011 | D5B-8011 | D5B-1011 | |
| 3 | D5B-5013 | D5B-8013 | D5B-1013 | ||
| 5 | D5B-5015 | D5B-8015 | D5B-1015 | ||
Cone-shaped actuator![]() | 1 | D5B-5021 | D5B-8021 | D5B-1021 | |
| 3 | D5B-5023 | D5B-8023 | D5B-1023 | ||
| 5 | D5B-5025 | D5B-8025 | D5B-1025 | ||
Wobble stick actuator![]() | Short spring | 1 | D5B-5511 | D5B-8511 | D5B-1511 |
| 3 | D5B-5513 | D5B-8513 | D5B-1513 | ||
| 5 | D5B-5515 | D5B-8515 | D5B-1515 | ||
| Long spring | 1 | - | - | D5B-1531 | |
| 3 | D5B-1533 | ||||
| 5 | D5B-1535 | ||||
Limit Switch Operating characteristics
| Actuator | Hemispheric Plunger | Cone-shaped Plunger | Wobble Stick | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Operating direction | ![]() | ![]() | ![]() | |||||||
| Operating characteristics | Type | M5 | M8 | M10 | M5 | M8 | M10 | M5 | M8 | M10 |
| Total travel TT * | X, Y | 1.0 mm | 1.2 mm | 1.3 mm | 2.2 mm | 3.0 mm | 4.0 mm | 22 mm | 23 mm | 30 m |
| Z | 0.8 mm | 0.9 mm | 1.0 mm | 0.8 mm | 0.9 mm | 1.0 m | - | |||
| Operating force OF (max.) | X, Y | 0.49 N | 0.74 N | 0.98 N | 0.20 N | 0.20 N | 0.39 N | 0.05 N | ||
| Z | 0.74 N | 0.98 N | 1.47 N | 0.74 N | 0.98 N | 1.47 N | - | |||
| Permissive operating force (max.) | X, Y, Z | 1.96 N | 1.96 N | 0.49 N | ||||||
| Pretravel PT * | X, Y | 0.6 mm | 0.6 mm | 0.7 mm | 0.6 mm | 1.4 mm | 2.0 mm | 11 mm | 11 mm | 14 mm |
| Z | 0.3 mm | 0.3 mm | 0.3 mm | 0.3 mm | 0.3 mm | 0.3 mm | - | - | - | |
*Reference Limit Switch value.
Selection Support Information of OMRON Limit Switch
Limit Switch Format Standards

Cautions and Prohibitions of OMRON Limit Switch
Limit Switch Usage notes
Limit Switch Handling
Do not apply excessive load to the cord (29.42N or less),
as this may cause the cord to break.
When bending the cord repeatedly, make sure the bending radius is R20mm or more.
Please be careful when handling the wire spring type as the tip is thin.
Limit Switch Regarding installation
- Do not tighten the nut with excessive force. For tightening torque and mounting hole dimensions of Limit Switch, see the table below.
- The screw part of the base has special screw dimensions, so it cannot be installed using standard tapping.
| Limit Switch type | Tightening torque (max) |
|---|---|
| M5 | 0.98N・m |
| M8 | 2.94N・m |
| M10 | 3.92N・m |
| Limit Switch Size/Type | M5 | M8 | M10 |
|---|---|---|---|
| A (mounting hole dimensions) | φ5 0~+0.3mm | φ8 0~+0.3mm | φ10 0~+0.3mm |
| B (plate thickness) | 3–7 mm | 4–6 mm | 6–10 mm |
| C (toothed washer outer dimensions) | φ9.2mm | φ15mm | φ18mm |

Limit Switch Operation
- Do not apply excessive force to the actuator. The actuator has a maximum strength of 14.7N, but if you are operating it repeatedly, do not apply more than 1.96N (0.49N for wire spring type).
- The operating characteristics vary depending on the direction of the force (X, Y, Z).
- Tactile Limit Switch have a mechanism in which an actuator moves when force is applied to the tip, opening and closing the internal switch.The principle is different from switches that only require touching the actuator (NL limit typetouch switch, D5C cylindrical type touch switch).
- If the wire spring type has too much stroke, it may break. The total movement (TT) should be used as a reference value only.
- If the Limit Switch is used in a location where it may come into direct contact with oil or water, please attach a protective cover (protective covers are not sold).
- When used outdoors, it may cause malfunctions due to ozone degradation, etc. Also, durability may be affected by differences in usage environment.