Operating Temperature Range | 0 – 80°C |
Standard Acquired | UL AWM 20266 |
Flat Model Signal Cable with Sheath
Model Number | Number of Cores |
SFX (Non-Shielded Type) | 20 |
26 | |
30 | |
34 | |
40 | |
50 | |
64 | |
SFX-SB (Shielded Type) | 20 |
26 | |
30 | |
34 | |
40 | |
50 | |
64 |
Model Number | Number of Cores | Total Length (m) | Flat Cable Part | Sheath (PVC) | Allowable Current (A) | Approximate Mass kg/km | |||
Conductor (Pc / mm) | Span | Overall Width | Thickness (mm) | Outer Diameter (mm) | |||||
SFX (Non-Shielded Type) | 20 | 1 / 5 / 10 / 20 / 50 / 100 | 7/0.127 (AWG28) * (0.08 mm2) | 24.13 | 25.4 | 0.9 | 8.5 | 1 | 66.5 |
26 | 31.75 | 33 | 0.9 | 9.6 | 81.9 | ||||
30 | 36.83 | 38.1 | 0.9 | 10.2 | 92.6 | ||||
34 | 41.91 | 43.2 | 0.9 | 11.1 | 103.7 | ||||
40 | 49.53 | 50.8 | 0.9 | 11.6 | 110.2 | ||||
50 | 62.23 | 63.5 | 0.9 | 13.3 | 159.1 | ||||
64 | 80.01 | 81.3 | 0.9 | 13.6 | 169.3 | ||||
SFX-SB (Shielded Type) | 20 | 7/0.127 (AWG28) * (0.08 mm2) | 24.13 | 25.4 | 0.9 | 8.5 | 1 | 85.8 | |
26 | 31.75 | 33 | 0.9 | 9.6 | 111.6 | ||||
30 | 36.83 | 38.1 | 0.9 | 10.4 | 118.2 | ||||
34 | 41.91 | 43.2 | 0.9 | 10.9 | 128.8 | ||||
40 | 49.53 | 50.8 | 0.9 | 11.8 | 144.5 | ||||
50 | 62.23 | 63.5 | 0.9 | 13.3 | 178.7 | ||||
64 | 80.01 | 81.3 | 0.9 | 13.6 | 201.2 |
Without Shield | With Shield | ||
Conductor Resistance | Ω / km or less (20°C) | 222 or less | 222 or less |
Insulation Resistance | MΩ-km | 10 | 5 |
Withstand Voltage | V/min.AC | 1500 | 1500 |
Capacitance | Approx. pF / m | 65 | 95 |
Characteristic Impedance | Approx. Ω | 95 | 75 |
Propagation Delay | Approx. ns / m | 5.2 | 6.0 |
Near-end Crosstalk | Approx. % | 6.5 | 6 |
Outstanding Flame Retardance | VW-I | VW-I |
Conductor Cross Section(mm2) | 0.08 | AWG size(AWG) | 28 | Finished outer diameter(mm) | 50.8 |
---|---|---|---|---|---|
Representative Standard | UL | Sheath (outer coating) material | PVC |