(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.
Select part number to Order Now/ Add to Cart
Temperature Controllers RS485 Communication Type
Temperature controllers are devices used to adjust the temperature of the controlled device to the set target temperature
[Feature]
● Input : Thermocouple (K, J, R, T, N, S, B) and Resistance thermometer (Pt100Ω / JPt100Ω.)
● Output : Relay contact output or SSR drive output free switching
● Power Supply Voltage : AC100~240VAC~50/60Hz±10%
● Mounting Size L X H (mm.) : 45 X 92
[Application]
It is used to adjust the temperature of the controlled device to the set target temperature
Part Number |
---|
C-MTCTRST |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship |
---|---|---|---|---|---|
฿ 1,888.96 | ECONOMY HEATER EQUIPMENTS | 1 Piece(s) | Available | Same day |
Loading...
Item | C-MTCTRS (Standard Type) | C-MTCTRST (RS485 Communication Type) |
Panel Dimension | 48×48 | 48×96 |
Control Output | Relay contact output (contact capacity AC250 V, 3 A resistance load) or SSR drive output (DC12 V, maximum 20 mA) free switching | |
Input | Thermocouple (K·J·R·T·N·S·B) Resistance thermometer (Pt100 and JPt100) | |
Control Method | ON/OFF, P, PI, PD and PID control | |
Alarm output | Upper limit alarm, lower limit alarm and positive and negative deviation range alarm | |
Sampling period | 100mS | |
Indication accuracy (thermocouple) | Normal temperature: PV±0.3% or ±3℃ (select the larger one) ±1-digit; above 200℃; PV±0.5% or ±2℃ (select the larger one) ±1-digit | |
Indication accuracy (resistance thermometer) | Normal temperature: PV±0.3% or ±3℃ (select the larger one) ±1-digit; above 200℃; PV±0.5% or ±2℃ (select the larger one) ±1-digit | |
Indication accuracy maintenance temperature range | Standard storage: 23±10℃ | |
Power Voltage | AC100~240VAC~50/60Hz±10% |
Input | Thermocouple / Temperature Measuring Resistor | Control Method | ON-OFF Control / PID Control with Self-Tuning / PID Control with Self-Tuning / PI Control / PD Control / P Control / Thermostats | Control Output | Relay Contact Output / SSR Drive Voltage Output |
---|---|---|---|---|---|
Number of Control Points | 2 | Number of Input Points(pcs.) | 1 | Power Supply Voltage | 100::240 |
Failure Detecting Function | Heater Breakage | Type | Including RS485 Communication | External Size(mm) | 48X96 |
Please check the type/dimensions/specifications of the part C-MTCTRST in the RS485 Communication Temperature Controller - Multi-Input series.
How can we improve?
How can we improve?