(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.

    Sales
  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart Item(s)
X
Loading...
  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 8:00 30/6/2024 to 5:00 1/7/2024. We apologize for the inconvenience.
  • แจ้งวันหยุดทำการในเดือน มิถุนายน 2567 | Notice holiday in June 2024 > คลิก

MISUMI Insulation Wires for Electric / Electronic / Communication Equipment(Rated Voltage:600V)

MISUMI offers products Insulation Wires for Electric / Electronic / Communication Equipment specified by Rated Voltage 600V from Wiring Components product category. There are a total of 7 items. Equipment and parts for electrical systems, cables and electrical connections. MISUMI products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.
Filter By
CAD
7 items
Sort By
30
60
90
  1. 1
  • You can add up to 6 items per a category to the compare list.
    Cable UL1015 / UL1283 / UL1284 UL / CSA Supported
    Cable UL1015 / UL1283 / UL1284 UL / CSA Supported
    Cable UL1015 / UL1283 / UL1284 UL / CSA Supported
    Cable UL1015 / UL1283 / UL1284 UL / CSA Supported

    Cable UL1015 / UL1283 / UL1284 UL / CSA Supported

    MISUMI

    600 V international standard single core wire. It has better heat resistance than Japanese standard of 600 V rated cable (IV, KIV). (operating temperature: 0 to 105°C)
    From: ฿ 778.45
    Days to Ship: day to ship Same day
    day to ship Same day
  • You can add up to 6 items per a category to the compare list.
    Sale
    Cable KIV PSE-Supported Ductile Model
    Until 31/03/2025
    Sale
    Until 31/03/2025

    Cable KIV PSE-Supported Ductile Model

    MISUMI

    • Single core ductile cable KIV type / PSE standard supported.
    • Compliant Standard JISC3316
    • 600V cable for general purposes.
    • Operating temperature range is 0-60℃.
    • 11 cable sizes are available. (0.75 sq.mm., 1,25 sq.mm., 2.0 sq.mm., 3.5 sq.mm., 5.5 sq.mm., 8 sq.mm., 14 sq.mm., 22 sq.mm., 38 sq.mm., 60 sq.mm. and 100 sq.mm.)
    • 6 Cable colors are available (W (White), BK (Black), R (Red), BE (Blue), Y (Yellow) and GN (Green).
    • Can order cable for 4 sizes of length. (10m, 50m, 100m and 200m)
    • Minimum bending radius is 8 times of finished outer diameter. (Fixed Part Only)
    • Vinyl insulator
    From: ฿ 734.71
    Special Price
    Days to Ship: day to ship Same day
    day to ship Same day
  • You can add up to 6 items per a category to the compare list.
    Sale
    Cable KIV PSE-Supported Ductile Model
    Until 31/03/2025
    Sale
    Until 31/03/2025

    Cable KIV PSE-Supported Ductile Model

    MISUMI

    • Single core ductile cable KIV type / PSE standard supported.
    • Compliant Standard JISC3316
    • 600V cable for general purposes.
    • Operating temperature range is 0-60℃.
    • 7 cable sizes are available. (0.5 sq.mm.,0.75 sq.mm., 1,25 sq.mm., 2.0 sq.mm., 3.5 sq.mm., 5.5 sq.mm. and 8 sq.mm.)
    • 6 Cable colors are available (W (White), BK (Black), R (Red), BE (Blue), Y (Yellow) and GN (Green).
    • Can order cable for 4 sizes of length. (10m, 50m, 100m and 200m).
    • Minimum bending radius is 8 times of finished outer diameter. (Fixed Part Only)
    • Insulated cable PVC (Polyvinyl Chloride)
    From: ฿ 3,303.23
    Special Price
    Days to Ship: day to ship Same day
    day to ship Same day
  • You can add up to 6 items per a category to the compare list.
    Sale
    Cable NAUL1015 UL Supported
    Until 31/03/2025
    Sale
    Until 31/03/2025

    Cable NAUL1015 UL Supported

    MISUMI

    600 V international standard single core wire. It has better heat resistance than the Japanese standard 600 V rated voltage (IV, KIV).
    From: ฿ 433.55
    Special Price
    Days to Ship: day to ship Same day
    day to ship Same day
  • You can add up to 6 items per a category to the compare list.
    Fixing Single-Core Cable ⋅ ECO Series, UL1015 600V

    Fixing Single-Core Cable ⋅ ECO Series, UL1015 600V

    MISUMI

    •AWG size : 10~24
    •Shield : None
    •Rated voltage : 600V
    •Ground wire : Colored YG (yellow/green)
    For complete product overview and details on Fixing Single-Core Cable ⋅ ECO Series, UL1015 600V see the sections below:
    From: ฿ 3,333.96
    Days to Ship: day to ship 6 Day(s)
    day to ship 6 Day(s)
  • You can add up to 6 items per a category to the compare list.
    Sale
    FA PSE Supported, 150 °C Heat-Resistant Fluorine Resin Insulated Cable
    Until 31/03/2025
    Sale
    Until 31/03/2025

    FA PSE Supported, 150 °C Heat-Resistant Fluorine Resin Insulated Cable

    MISUMI

    600 V heat-resistant single core wire. Tin-plated and annealed copper stranded wire is used for the conductor, so the continuous operating temperature is -60°C to 150°C.
    From: ฿ 412.39
    Special Price
    Days to Ship: day to ship Same day
    day to ship Same day
  • You can add up to 6 items per a category to the compare list.
    Cable NAUL1283 / NAUL1284 UL Supported

    Cable NAUL1283 / NAUL1284 UL Supported

    MISUMI

    600 V international standard single core wire. You can purchase in units of 1 m.
    From: ฿ 15,913.17
    Days to Ship: day to ship 3 Day(s)
    day to ship 3 Day(s)
Brand
Product Series
From
Days to Ship
Specifications
Conductor Cross Section(mm2)
AWG size(AWG)
Sheath (outer coating) color
Rated Voltage
Properties
Overall Length(m)
Finished outer diameter(mm)
Representative Standard
Insulation body materials
Shield
Logarithm
Sheath (outer coating) material
You can add up to 6 items per a category to the compare list.
Cable UL1015 / UL1283 / UL1284 UL / CSA Supported
Cable UL1015 / UL1283 / UL1284 UL / CSA Supported
Cable UL1015 / UL1283 / UL1284 UL / CSA Supported
Cable UL1015 / UL1283 / UL1284 UL / CSA Supported
You can add up to 6 items per a category to the compare list.
Sale
Cable KIV PSE-Supported Ductile Model
Until 31/03/2025
You can add up to 6 items per a category to the compare list.
Sale
Cable KIV PSE-Supported Ductile Model
Until 31/03/2025
You can add up to 6 items per a category to the compare list.
Sale
Cable NAUL1015 UL Supported
Until 31/03/2025
You can add up to 6 items per a category to the compare list.
Fixing Single-Core Cable ⋅ ECO Series, UL1015 600V
You can add up to 6 items per a category to the compare list.
Sale
FA PSE Supported, 150 °C Heat-Resistant Fluorine Resin Insulated Cable
Until 31/03/2025
You can add up to 6 items per a category to the compare list.
Cable NAUL1283 / NAUL1284 UL Supported
Brand

MISUMI

MISUMI

MISUMI

MISUMI

MISUMI

MISUMI

MISUMI

Product Series

Cable UL1015 / UL1283 / UL1284 UL / CSA Supported

Cable KIV PSE-Supported Ductile Model

Cable KIV PSE-Supported Ductile Model

Cable NAUL1015 UL Supported

Fixing Single-Core Cable ⋅ ECO Series, UL1015 600V

FA PSE Supported, 150 °C Heat-Resistant Fluorine Resin Insulated Cable

Cable NAUL1283 / NAUL1284 UL Supported

From

฿ 778.45

฿ 734.71

Special Price

On Sale Until 31/03/2025

฿ 3,303.23

Special Price

On Sale Until 31/03/2025

฿ 433.55

Special Price

On Sale Until 31/03/2025

฿ 3,333.96

฿ 412.39

Special Price

On Sale Until 31/03/2025

฿ 15,913.17

Days to Ship Same day Same day Same day Same day 6 Day(s) Same day 3 Day(s)
Specifications
                Conductor Cross Section(mm2)0.75 ~ 1.250.75 ~ 3.520.75 ~ 3.50.3 ~ 5.50.3 ~ 3.58
                AWG size(AWG)16 ~ 1812 ~ 181412 ~ 1810 ~ 2212 ~ 228
                Sheath (outer coating) colorBlack / Red / Green / Blue / OtherBlack / Red / Yellow / Green / BlueYellowBlack / White / OtherBlack / White / Brown / Red / Orange / YellowBlack / White / Red / Yellow / Green / Blue / OtherBlack / White / Red / Green / Blue / Other
                Rated Voltage600V600V600V600V600V600V600V
                PropertiesHeat-Resistance---Oil Resistance / Chemical ResistanceHeat-Resistance / Cold Resistance / Chemical ResistanceHeat-Resistance
                Overall Length(m)10 ~ 10010 ~ 20020010 ~ 30510010 ~ 200153
                Finished outer diameter(mm)3 ~ 3.42.7 ~ 4.13.42.91 ~ 4.162.4 ~ 41.22 ~ 3.37.2
                Representative StandardUL / CSA(c-UL)PSEPSEULUL / CSA(c-UL)PSEUL / CSA(c-UL)
                Insulation body materials-------
                ShieldNANANANANANANA
                Logarithm-------
                Sheath (outer coating) materialPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)-OtherPVC (Polyvinyl Chloride)

                Loading...

                1. 1

                Related Categories to Insulation Wires for Electric / Electronic / Communication Equipment

                FAQ Wire Cable

                Question: How many types of wires are there and how to choose the right wires?
                Answer: Cable can be separated into 2 types.
                1. Low voltage cable which using for electric system with voltage 750V or less. Typically, this type of cables is made of copper or aluminum such as THW, VAF, VCT and NYY.
                2. High voltage cable which using for electric system with voltage 1kV-36kV, conduct structure are stranded wire such as Aluminum Conductor (AAC), Aluminum Alloy Conductor (AAAC), Aluminum Conductor Steel Reinforced (ACSR), Partial Insulated Cable (PIC), Space Aerial Cable (SAC), Preassembly Aerial Cable (PAC) and Cross-linked Polyethylene (XLPE)
                Cable should select based on using electrical voltage and current. Moreover, we should select cable insulation which suit for operating environment such as Heat resistance, weather resistance or chemical resistance.
                Question: What are the components in the cable?
                Answer: Cable components are consisting of 3 parts as below.
                1. Conductor
                Made of metal wire, use for transmitting the electricity.
                2. Insulator
                Insulator is the component which is cover conductor wire to block electricity from conductor transmit to another part.
                3. Sheath
                The outer cover of cable use for protecting any harm to cable inside such as scratch, weather, and heat.
                Question: What types of wires are used in households?
                Answer: Cable for home appliance is low voltage cable type which is applicable for voltage 750V or less such as,
                1. THW cable, which consist of solid-core conductor wire with PVC insulator. Suit for wiring inside the building.
                2. VHF cable, which consist of multiple solid-core conductor wire with colored insulator inside white sheath. Suit for wiring inside the building.
                3. VCT cable, which consist of multiple stranded conductor wire with insulator inside the black sheath. Due to, heat and water resistance properties, this cable can be wiring outside the building. However, it cannot not wire directly underneath the ground. I should wire through electrical conduit pipe.
                Question: What applications are 1.5 mm wires suitable for?
                Answer: 1.5 mm2 is suit for general electrical home appliance which using current not exceed 15A and power does not exceed 3.5 kW.
                Question: Why are there different colors of wires?
                Answer: Electrical wires are identified by their insulating casings. To identify wires quickly and easily, nearly all electrical and electronic devices use color-coding.
                A live or hot circuit is typically black or red, but yellow or blue are also suitable.
                Neutral wires can be gray or white.
                Ground wires can be green, green with yellow stripes, or bare copper.
                Due to the colors' variability, learning the ropes can be confusing. When installing a new light fixture or during a blackout, you might find it helpful to know the meaning of the colors. Electric wires carry high voltages that may cause injury if you are not careful.