FUJI ELECTRIC Overload Relays(Auxiliary Contact:1a1b)

FUJI ELECTRIC offers products Overload Relays specified by Auxiliary Contact 1a1b from Electrical & Controls product category. There are a total of 4 items. Parts and equipment for controlling machines and electrical systems. Controllers and power supplies. FUJI ELECTRIC products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.
Filter By
CAD
4 items
Sort By
30
60
90
  1. 1
  • You can add up to 6 items per a category to the compare list.
    Sale
    New SC/NEO SC Series Thermal Relay
    Until 31/03/2025
    Sale
    Until 31/03/2025

    New SC/NEO SC Series Thermal Relay

    FUJI ELECTRIC

    - Thermal Overload Relays New SC / NEO SC Series 2E type
    - Part number for series including of TK-0N, TK-5-1N and TK-N
    - Operating characteristics: The operating characteristics of a thermal overload relay represent its tripping time and response current starting from cold or hot state.
    - Resistance to vibration and shock: The relays are tested to confirm that the items specified by JEM 1356 are satisfied.
    - Switching reset: Automatic reset and Manual Reset
    - current Auxiliary contact: 1NO+1NC.
    From: ฿ 625.00
    Special Price
    Days to Ship: day to ship Same day
    day to ship Same day
  • You can add up to 6 items per a category to the compare list.
    New SC / NEO SC Series Thermal Relay

    New SC / NEO SC Series Thermal Relay

    FUJI ELECTRIC

    - Thermal overload relays Quick operating type
    - Part number for series including of TR-0NQ, TR-0NQH, TR-0NQH/A, TR-5-1NQ and TR-N3QH.
    - Operating characteristics: The operating characteristics of a thermal overload relays represents its tripping time and response current starting from cold or hot state.
    - Resistance to vibration and shock: The relays are tested to confirm that the items specified by JEM 1356 are satisfied.
    - Auxiliary contact: 1NO+1NC
    - Number of Poles: 3
    - Switching reset: Automatic reset and Manual Reset
    From: ฿ 1,283.33
    Days to Ship: day to ship 61 Day(s)
    day to ship 61 Day(s)
  • You can add up to 6 items per a category to the compare list.
    New SC / NEO SC Series Time-Lag Type Thermal Relay

    New SC / NEO SC Series Time-Lag Type Thermal Relay

    FUJI ELECTRIC

    - Thermal Overload Relays New SC / NEO SC Series Long-time operating type
    - Part number for series including of TR-0NLH, TR-5-1NLH and TR-N
    - Operating characteristics: The operating characteristics of a thermal overload relay represent its tripping time and response current starting from cold or hot state.
    - Resistance to vibration and shock: The relays are tested to confirm that the items specified by JEM 1356 are satisfied.
    - Making and breaking capacity: Operational current 2 (A)
    - Switching reset: Automatic reset and Manual Reset
    From: ฿ 2,883.33
    Days to Ship: day to ship 61 Day(s)
    day to ship 61 Day(s)
  • You can add up to 6 items per a category to the compare list.
    New SC / NEO SC Series Thermal Relay with Quick Terminal TR-0NY Type

    New SC / NEO SC Series Thermal Relay with Quick Terminal TR-0NY Type

    FUJI ELECTRIC

    - Thermal Relay with Quick Terminal TR-0NY Type
    - Part number for series including of TR-0NY_.
    - Operating characteristics: The operating characteristics of a thermal overload relay represent its tripping time and response current starting from cold or hot state.
    - Resistance to vibration and shock: The relays are tested to confirm that the items specified by JEM 1356 are satisfied.
    - Auxiliary contact: 1NO+1NC
    - Number of Poles: 3
    - Switching reset: Automatic reset and Manual Reset
    - UL File No. E44592
    From: ฿ 1,140.00
    Days to Ship: day to ship 90 Day(s)
    day to ship 90 Day(s)
Brand
Product Series
From
Days to Ship
Type
Operating Method
Motor capacity 400 to 440-VAC class(kW/A)
Motor Capacity VAC 200–220 Class(kW/A)
Coil rated voltage(V)
Number of Poles
Auxiliary Contact
Representative Standard
Dimension length(mm)
Dimension width(mm)
Dimension thickness(mm)
You can add up to 6 items per a category to the compare list.
Sale
New SC/NEO SC Series Thermal Relay
Until 31/03/2025
You can add up to 6 items per a category to the compare list.
New SC / NEO SC Series Thermal Relay
You can add up to 6 items per a category to the compare list.
New SC / NEO SC Series Time-Lag Type Thermal Relay
You can add up to 6 items per a category to the compare list.
New SC / NEO SC Series Thermal Relay with Quick Terminal TR-0NY Type
Brand

FUJI ELECTRIC

FUJI ELECTRIC

FUJI ELECTRIC

FUJI ELECTRIC

Product Series

New SC/NEO SC Series Thermal Relay

New SC / NEO SC Series Thermal Relay

New SC / NEO SC Series Time-Lag Type Thermal Relay

New SC / NEO SC Series Thermal Relay with Quick Terminal TR-0NY Type

From

฿ 625.00

Special Price

On Sale Until 31/03/2025

฿ 1,283.33

฿ 2,883.33

฿ 1,140.00

Days to Ship Same day 61 Day(s) 61 Day(s) 90 Day(s)
Type-Thermal relayThermal relayThermal relay
Operating Method-Irreversible typeIrreversible typeIrreversible type
Motor capacity 400 to 440-VAC class(kW/A)----
Motor Capacity VAC 200–220 Class(kW/A)----
Coil rated voltage(V)----
Number of Poles3333
Auxiliary Contact1a1b1a1b1a1b1a1b
Representative StandardCE / UL / CUL / TUV / CCC / CSACCC--
Dimension length(mm)77 ~ 18380 ~ 11191.5 ~ 14981
Dimension width(mm)44 ~ 19744 ~ 6883.5 ~ 14944
Dimension thickness(mm)58.5 ~ 18259.5 ~ 109.5100 ~ 158.559

Loading...

  1. 1

Related Categories to Overload Relays

FAQ Overload Relays

Question: What is the purpose of terminals 95 and 96 on an overload relay?
Answer: In electrical systems, terminals 95 and 96 on an overload relay serve a crucial role in motor protection. Terminal 95 is the common terminal for the trip circuit, and terminal 96 is the normally close contact. When the overload relay detects excessive current in a motor, it activates the trip circuit. This action causes the normally close contact at terminal 96 to open, initiating protective measures, such as disconnecting the motor from the power supply, to prevent damage due to overcurrent.
Question: How do overload relays contribute to electrical safety?
Answer: Overload relays enhance electrical safety by monitoring motor currents. If currents exceed safe levels, the relay triggers protective actions, preventing motor overheating and potential fire hazards. By swiftly disconnecting power during overloads, they safeguard equipment, reduce downtime, and comply with safety standards. Overload relays offer early warnings of issues, allowing for timely maintenance. Customizable to specific current limits, they contribute to adaptability and seamless integration with control systems, ensuring efficient protection and reliable operation in various electrical applications.
Question: What factors determine the correct setting for an overload relay?
Answer: The correct overload relay setting depends on factors such as motor rating, type, and efficiency. Considerations include inrush current during startup, operating conditions, and load variations. Crucial aspects involve service factors, thermal models, and adherence to standards. Following manufacturer recommendations, finding a balance between protection sensitivity and avoiding unnecessary tripping is key. Regular reviews accommodate changes in the electrical system or equipment, ensuring optimal protection, compliance with standards, and reliability across various applications.
Question: What role does an overload relay play in a 3-phase system?
Answer: In a 3-phase system, an overload relay protects electric motors by monitoring current. When it detects excess current, signaling an overload, the relay activates a trip circuit that rapidly disconnects the motor. This prevents overheating, safeguarding the motor from damage and mitigating fire hazards. The overload relay contributes to overall system reliability, with adjustable settings and integration capabilities enhancing its adaptability and automation in motor protection.
Question: How can the principle of overload be beneficial in relay design?
Answer: The principle of overload in relay design is pivotal for electrical system safety. Overload relays, responsive to excessive current, disconnect power swiftly, preventing equipment damage and fire hazards. Adjustable settings accommodate diverse motor requirements, ensuring adaptability. Early warning features facilitate timely maintenance, minimizing downtime. This principle aligns with safety standards, promoting compliance. Beyond protection, overload relays contribute to energy efficiency by optimizing motor performance under varying loads. Overall, they play a crucial role in enhancing equipment longevity, system reliability, and adherence to safety regulations in electrical systems.
Question: What distinguishes bimetallic overload relays from electronic types?
Answer: Bimetallic and electronic overload relays differ in technology and performance. Bimetallic relays use physical expansion of bimetallic strips for current detection, providing simplicity but less precision. Electronic relays, employing sensors and microprocessors, offer higher sensitivity, adjustability, and advanced motor protection. While bimetallic relays are cost-effective for basic applications, electronic relays excel in complex systems, delivering enhanced performance, adaptability, and reliability. The choice depends on the application's needs, with bimetallic relays suited for simplicity and electronic relays for advanced functionality.