(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.

    Sales
  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart Item(s)
X
Loading...
  • การยกเลิกจำหน่ายสินค้าประเภทอุปกรณ์นิวเมติกส์ (Pneumatic equipment) รุ่น “Economy Series”​ | Notice of End of Sales for Economy Series Pneumatic Equipment Category > คลิก
  • แจ้งวันหยุดทำการในเดือน กรกฎาคมและสิงหาคม 2567 | Notice holiday in July and August 2024 > คลิก

FUJI ELECTRIC Earth Leakage Breakers (Low Capacity)(Rated Operating Voltage:AC100/200)

FUJI ELECTRIC offers products Earth Leakage Breakers (Low Capacity) specified by Rated Operating Voltage AC100/200 from Electrical & Controls product category. There are a total of 4 items. Parts and equipment for controlling machines and electrical systems. Controllers and power supplies. FUJI ELECTRIC products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.
CAD
4 items
Sort By
30
60
90
  1. 1
  • You can add up to 6 items per a category to the compare list.
    Breaker for Distribution Board, Compact Twin Series Leakage Breaker (ELB) (Low Capacity)

    Breaker for Distribution Board, Compact Twin Series Leakage Breaker (ELB) (Low Capacity)

    FUJI ELECTRIC

    [Features]
    · Compact twin 2 pole product for distribution board unified to 25 mm width ELB.
    From: ฿ 5,488.34
    Days to Ship: day to ship 31 Day(s)
    day to ship 31 Day(s)
  • You can add up to 6 items per a category to the compare list.
    JIS Compatible Leakage Breaker (Low Capacity)

    JIS Compatible Leakage Breaker (Low Capacity)

    FUJI ELECTRIC

    [Features]
    · Home distribution board or various electrical devices (vending machines, refrigerated showcase etc.).
    · ELB for insertion.
    From: ฿ 2,375.01
    Days to Ship: day to ship Quote
    day to ship Quote
  • You can add up to 6 items per a category to the compare list.
    DG Series Leakage Breaker for Electrical Works (Low Capacity)

    DG Series Leakage Breaker for Electrical Works (Low Capacity)

    FUJI ELECTRIC

    [Features]
    · Sensitivity current switching type can be set up to 1000mA over (125AF).
    · Auxiliary switches (W) and alarm switches (K) can be installed on all types.
    · 3P products of 225AF or less can be used for both wiring protection and induction motor protection.
    · Terminal covers with sealing screws are standard equipment in all models.
    · For frames 60 to 225A Crimp terminals are the standard equipment.
    From: ฿ 4,656.67
    Days to Ship: day to ship 61 Day(s)
    day to ship 61 Day(s)
  • You can add up to 6 items per a category to the compare list.
    G-TWIN Breaker EW Series EAN (Low Capacity)

    G-TWIN Breaker EW Series EAN (Low Capacity)

    FUJI ELECTRIC

    [Features]
    · With protection of single-phase 3-wire neutral line phase interruption, protecting circuit over voltage caused by FAB, ELB single-phase 3-wire neutral line phase interruption, FAB, ELB.
    From: ฿ 12,899.35
    Days to Ship: day to ship Quote
    day to ship Quote
Brand
Product Series
From
Days to Ship
Ampere frame AF
Rated block capacity AC 100 V(kA)
Rated block capacity AC 200 V(kA)
Rated block capacity AC 400 V(kA)
Number of Poles
Rated Operating Voltage(V)
Rated Current(A)
rate sensitivity current(mA)
Mounting Method
Representative Standard
Dimension height(mm)
Dimension width(mm)
Dimension depth(mm)
Rated block capacity, voltages except VAC 100/200/400, VDC 250
Connection Method
You can add up to 6 items per a category to the compare list.
Breaker for Distribution Board, Compact Twin Series Leakage Breaker (ELB) (Low Capacity)
You can add up to 6 items per a category to the compare list.
JIS Compatible Leakage Breaker (Low Capacity)
You can add up to 6 items per a category to the compare list.
DG Series Leakage Breaker for Electrical Works (Low Capacity)
You can add up to 6 items per a category to the compare list.
G-TWIN Breaker EW Series EAN (Low Capacity)
Brand

FUJI ELECTRIC

FUJI ELECTRIC

FUJI ELECTRIC

FUJI ELECTRIC

Product Series

Breaker for Distribution Board, Compact Twin Series Leakage Breaker (ELB) (Low Capacity)

JIS Compatible Leakage Breaker (Low Capacity)

DG Series Leakage Breaker for Electrical Works (Low Capacity)

G-TWIN Breaker EW Series EAN (Low Capacity)

From

฿ 5,488.34

฿ 2,375.01

฿ 4,656.67

฿ 12,899.35

Days to Ship 31 Day(s) Quote 61 Day(s) Quote
Ampere frame AF50AF30AF or less30AF or less / 50AF50AF
Rated block capacity AC 100 V(kA)51.52.5 ~ 5-
Rated block capacity AC 200 V(kA)2.51.52.5-
Rated block capacity AC 400 V(kA)----
Number of Poles22 / 32 / 33
Rated Operating Voltage(V)AC100/200AC100/200AC100/200AC100/200
Rated Current(A)15 ~ 30301.4 ~ 5040
rate sensitivity current(mA)15 ~ 3015 ~ 3015 ~ 3030
Mounting MethodFasten With ScrewsFasten With ScrewsFasten With ScrewsFasten With Screws
Representative StandardPSEPSEPSEPSE
Dimension height(mm)96 ~ 11070 ~ 80120100
Dimension width(mm)2568 ~ 9050 ~ 7575
Dimension depth(mm)76.5638484
Rated block capacity, voltages except VAC 100/200/400, VDC 250----
Connection Method-Surface typeSurface typeSurface type

Loading...

  1. 1

Related Categories to Earth Leakage Breakers (Low Capacity)

FAQ Earth Leakage Breakers (Low Capacity)

Question: What is the function and capacity of an Earth Leakage Circuit Breaker (ELCB)?
Answer: An Earth Leakage Circuit Breaker (ELCB) is a crucial safety device in electrical installations. Its primary function is to protect individuals from electric shock by automatically disconnecting the power supply when a fault occurs. ELCBs are designed to detect imbalances in the current flowing between live and neutral conductors. When a leakage current exceeds its rated value (typically 30mA or 100mA), the ELCB trips, interrupting the circuit and preventing potentially fatal injuries. This rapid response time ensures immediate protection against electric shock hazards.
Question: What are the typical reasons for an ELCB to trip, and how does one troubleshoot it?
Answer: ELCB Tripping: Reasons and Troubleshooting
Common Reasons:
1.Earth Leakage: Current flows through unintended path (faulty appliance, wiring, water).
2.Circuit Overload: Current exceeds ELCB's rating (too many appliances).
3.Nuisance Trips: High sensitivity, electrical noise, power surges.
4.Troubleshooting:

Identify affected circuit and appliances.
1.Turn off all appliances and reset ELCB.
2.Switch on appliances one by one to find the culprit.
3.Repair/replace faulty appliance or fix wiring.
4.Test ELCB again with all appliances on.
Question: How does one determine the appropriate tripping capacity and minimum rating for an ELCB?
Answer: 1. Tripping Capacity: This depends on potential fault currents and the maximum allowable leakage. Factors include:
- Fault Current Loop Impedance: The resistance of the path the fault current takes to Earth, influencing how quickly the ELCB trips.
- Maximum Earth Fault Current: The highest current the ELCB should allow to flow before tripping, typically 30mA or 100mA.

2.Minimum Current Rating: This is based on the circuit's maximum current demand and needs to be equal to or higher than the expected circuit load. Factors include:
- Circuit Load: The total current drawn by all appliances connected to the circuit.
- Diversity Factor: Considers that all appliances won't operate at maximum load simultaneously.
Question: What are the standard sizes of earth leakage, and how do you calculate the correct size for your needs?
Answer: Earth leakage circuit breakers (ELCBs) come in a range of standard sizes, typically specified by their rated current (In) and tripping sensitivity (IΔn). Common sizes include:
1.Current (In): 16A, 20A, 25A, 32A, 40A, 63A, 80A, 100A, 125A
2.Sensitivity (IΔn): 30mA, 100mA, 300mA

Choosing the correct size for your needs involves two main considerations:
1.Maximum Current Demand: Calculate the total current drawn by all appliances connected to the circuit.
2.Tripping Sensitivity: Based on safety requirements and potential fault scenarios.

Example: Sum all appliance currents:
Appliance A: 300W (1.3A)
Appliance B: 500W (2.17A)
Total current demand: 3.47A
This means you need an ELCB with a rated current (In) equal to or greater than 3.47A.
Question: How do you measure earth leakage current, and what is the acceptable range for safety standards?
Answer: Measuring earth leakage current requires a specialized instrument called an earth leakage clamp meter. It clamps around the earth conductor of the circuit and measures the current flowing through it. Acceptable levels for safety vary depending on regulations and application:
- IEC 60364-4-42: 30mA maximum for general residential installations.
- BS 7671: 30mA for most domestic circuits, 100mA for specific situations (e.g., bathrooms).