FUJI ELECTRIC Circuit Breakers (Low Capacity)(Mounting Method:Fasten With Screws)

FUJI ELECTRIC offers products Circuit Breakers (Low Capacity) specified by Mounting Method Fasten With Screws from Electrical & Controls product category. There are a total of 4 items. Parts and equipment for controlling machines and electrical systems. Controllers and power supplies. FUJI ELECTRIC products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.
Filter By
CAD
4 items
Sort By
30
60
90
  1. 1
  • You can add up to 6 items per a category to the compare list.
    Sale
    Small Form FAB/ELB Series Safety Breaker Type Wiring Circuit Breaker (Low Capacity)
    Until 31/03/2025
    Sale
    Until 31/03/2025

    Small Form FAB/ELB Series Safety Breaker Type Wiring Circuit Breaker (Low Capacity)

    FUJI ELECTRIC

    - Small type breaker (Circuit breaker for wiring use) FAB/ELB series from Fuji electric. - Breaker sizes are small; their size is same as breaker which typically using at home. - Rated current are 3 types available 15A, 20A and 30A. - Can be select no. of poles, 1 or 2 poles. - Rated operating voltage can be select 2 types: AC100 or AC100/200. - Rated block capacity at AC 200 V is 1.5 kA - Breaker accessory, handle lock cover is sold separately. (Part no. BZ-L05B)
    From: ฿ 358.33
    Special Price
    Days to Ship: day to ship Same day
    day to ship Same day
  • You can add up to 6 items per a category to the compare list.
    D-Series Auto-Breaker for Electrical Work (Low-Capacity)

    D-Series Auto-Breaker for Electrical Work (Low-Capacity)

    FUJI ELECTRIC

    - Auto-Breaker for Electrical Work (Low-Capacity) D Series from Mitsubishi electric. - Sensitivity current switching type can be set up to 1000mA (125AF or more). - Auxiliary switch (W) and alarm switch (K) can be attached to all models. - Possible to select 2 or 3 poles. - 3P products which below 225AF are both wiring protection and induction motor protection products. - A terminal cover with a sealing screw is standard equipment for all models. - 60-225A frames come standard with crimp terminals.
    From: ฿ 1,696.67
    Days to Ship: day to ship 61 Day(s)
    day to ship 61 Day(s)
  • You can add up to 6 items per a category to the compare list.
    Circuit Breaker for Distribution Board Compact Twin Series Auto Breaker (FAB) (Low Capacity)

    Circuit Breaker for Distribution Board Compact Twin Series Auto Breaker (FAB) (Low Capacity)

    FUJI ELECTRIC

    - Circuit Breaker for Distribution Board Compact Twin Series from Fuji electric. - Frame size of compact twin series is 50AF. - 3 types of terminal structure are available, C type (Supply side: Screw type terminal, Load side: Screw type terminal), P type (Supply side: Plug-in type terminal, Load side: screw type terminal), Q type (Supply side: Plug-in type terminal, Load side: insertion type terminal). - No. of pole is 2 poles. - Rated current can select 3 values 15A, 20A and 30A.
    From: ฿ 985.00
    Days to Ship: day to ship 31 Day(s)
    day to ship 31 Day(s)
  • You can add up to 6 items per a category to the compare list.
    Wiring Circuit Breaker L Series (Low Capacity)

    Wiring Circuit Breaker L Series (Low Capacity)

    FUJI ELECTRIC

    - Instantaneous trip fixed type MCCB (Molded Case Circuit Breakers) L series from Fuji electric. - Frame size of breaker is 50. - No. of poles is 3 poles. - Rated break capacity: 42 kA at 500 VAC, 50 kA at 440 VAC and 100 kA at 230 VAC. - Optional accessories (Sold separately): External control handle (BZ-V20C, BZ-N20B), Short terminal cover (BZ-TS20B-3, BZ-TB20B-3), Handle lock cover (BZ-L20C), Single hole flat terminal (BZ-S20B-503), Mechanical interlock (BZ-M120C-3, BZ-M220C-3, BZ-M320C-3). -Trip button available.
    From: ฿ 8,016.67
    Days to Ship: day to ship 90 Day(s)
    day to ship 90 Day(s)
Brand
Product Series
From
Days to Ship
Ampere frame
Rated block capacity AC 100 V(kA)
Rated block capacity AC 200 V(kA)
Rated block capacity AC 400 V(kA)
Rated Braking Capacity at Rated Voltage of VDC 250(kA)
Rated block capacity, voltages except VAC 100/200/400, VDC 250
Number of Poles
Rated Current(A)
Mounting Method
Connection Method
Representative Standard
Dimension height(mm)
Dimension width(mm)
Dimension depth(mm)
You can add up to 6 items per a category to the compare list.
Sale
Small Form FAB/ELB Series Safety Breaker Type Wiring Circuit Breaker (Low Capacity)
Until 31/03/2025
You can add up to 6 items per a category to the compare list.
D-Series Auto-Breaker for Electrical Work (Low-Capacity)
You can add up to 6 items per a category to the compare list.
Circuit Breaker for Distribution Board Compact Twin Series Auto Breaker (FAB) (Low Capacity)
You can add up to 6 items per a category to the compare list.
Wiring Circuit Breaker L Series (Low Capacity)
Brand

FUJI ELECTRIC

FUJI ELECTRIC

FUJI ELECTRIC

FUJI ELECTRIC

Product Series

Small Form FAB/ELB Series Safety Breaker Type Wiring Circuit Breaker (Low Capacity)

D-Series Auto-Breaker for Electrical Work (Low-Capacity)

Circuit Breaker for Distribution Board Compact Twin Series Auto Breaker (FAB) (Low Capacity)

Wiring Circuit Breaker L Series (Low Capacity)

From

฿ 358.33

Special Price

On Sale Until 31/03/2025

฿ 1,696.67

฿ 985.00

฿ 8,016.67

Days to Ship Same day 61 Day(s) 31 Day(s) 90 Day(s)
Ampere frame-30AF or less / 50AF50AF50AF
Rated block capacity AC 100 V(kA)1.5-5-
Rated block capacity AC 200 V(kA)1.52.52.5-
Rated block capacity AC 400 V(kA)---50
Rated Braking Capacity at Rated Voltage of VDC 250(kA)----
Rated block capacity, voltages except VAC 100/200/400, VDC 250--AvailableAvailable
Number of Poles22 / 323
Rated Current(A)15 ~ 301.4 ~ 5015 ~ 300.7 ~ 40
Mounting MethodFasten With ScrewsFasten With ScrewsFasten With ScrewsFasten With Screws
Connection Method-Surface type-Surface type
Representative Standard-PSEPSEPSE
Dimension height(mm)7012096 ~ 110130 ~ 150
Dimension width(mm)3250 ~ 752575
Dimension depth(mm)558476.580 ~ 102

Loading...

  1. 1

Related Categories to Circuit Breakers (Low Capacity)

FAQ Circuit Breakers (Low Capacity)

Question: Types of circuit breaker and their applications.
Answer: Circuit breakers mainly are categorized based on application as per voltage.
1. Low Voltage Circuit Breaker
Low-voltage circuit breakers are typically used in applications such as lighting circuits, motor control centers, feeder circuits, and any application in which electrical power needs to be turned on and off and overcurrent protection is required.
2. Medium Voltage Circuit Breakers
Medium voltage breakers are designed to be operated electrically by a closing solenoid or a stored energy mechanism. Manual operation is used primarily for breaker maintenance.
3. HIGH-VOLTAGE CIRCUIT BREAKERS
High-voltage circuit breakers are mechanical switching devices that connect and break current circuits (operating currents and fault currents) and carry the nominal current in the closed position.
Question: What can cause the main circuit breaker to trip?
Answer: The most common cause of a tripped circuit breaker is an overload in that circuit. Each circuit is only intended to carry a certain electrical load, and if it exceeds this load, it will cause the breaker to trip. This is important, as overloading a circuit can cause the wiring to heat up and potentially create a fire risk. In fact, it is this excess heat running through the circuit that causes the breaker to trip.
Question: How we know that have to replace breaker?
Answer: 1. Breaker trips frequently.
2. Burning smell coming from the electrical panel.
3. Poorly performing appliances and light fixtures.
4. Breaker fails to stay in reset mode.
5. Visible signs of physical damage.
Question: How do I know whether to get a 15 or 20 A circuit breaker?
Answer: Calculate the total current of all electrical equipment. that want to be connected to the breaker The sum of the calculated current should not exceed 80% of the breaker capacity. For example, a 15 A breaker can be connected to external devices up to 12A (15 x 0.80 = 12), and a 20 A breaker can be connected to external devices up to 16A (20 x 0.80 = 16). This can lead to calculation errors and can cause a fire.