Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.
Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 8:00 8/9/2024 to 5:00 9/9/2024. We apologize for the inconvenience.
การยกเลิกจำหน่ายสินค้าประเภทอุปกรณ์นิวเมติกส์ (Pneumatic equipment) รุ่น “Economy Series” |
Notice of End of Sales for Economy Series Pneumatic Equipment Category > คลิก
* This form is only for feedback/comment on our website and service
Feedback
Name (Optional)
E-mail Address (Optional)
Tel (Optional)
Your feedback is essential for our continuous improvement
Thank you for your cooperation.
Your feedback is essential for our continuous improvement.
Schneider Electric Circuit Breakers (Low Capacity)
Circuit Breakers (Low Capacity) products in the Electrical & Controls category from Schneider Electric. The product can be selected based on many product specifications such as Rated block capacity AC 100 V, Rated block capacity AC 200 V, Rated block capacity AC 400 V, Rated Braking Capacity at Rated Voltage of VDC 250, Rated Current. Schneider Electric offers products around 1 items and the product specifications can easily be compared. Parts and equipment for controlling machines and electrical systems. Controllers and power supplies. Schneider Electric products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.
This range of supplementary protectors are used in direct current circuits (Industrial control and automations, transport, renewable energy).They combine the following functions of circuit protection against short-circuit and overload currents, control and isolation. Tripping curves: C curve - Overcurrent protection for any type of applicationThe green strip indicates that all the poles are open and allows work to be carried out on the downstream circuit in complete safetySuitable for isolation as defined in IEC / EN 60947-2Current limitation in the event of a fault: fast opening of the contacts prevents the loads from being damaged in the event of a short-circuit.
Question: Types of circuit breaker and their applications.
Answer: Circuit breakers mainly are categorized based on application as per voltage.
1. Low Voltage Circuit Breaker
Low-voltage circuit breakers are typically used in applications such as lighting circuits, motor control centers, feeder circuits, and any application in which electrical power needs to be turned on and off and overcurrent protection is required.
2. Medium Voltage Circuit Breakers
Medium voltage breakers are designed to be operated electrically by a closing solenoid or a stored energy mechanism. Manual operation is used primarily for breaker maintenance.
3. HIGH-VOLTAGE CIRCUIT BREAKERS
High-voltage circuit breakers are mechanical switching devices that connect and break current circuits (operating currents and fault currents) and carry the nominal current in the closed position.
Question: What can cause the main circuit breaker to trip?
Answer: The most common cause of a tripped circuit breaker is an overload in that circuit. Each circuit is only intended to carry a certain electrical load, and if it exceeds this load, it will cause the breaker to trip. This is important, as overloading a circuit can cause the wiring to heat up and potentially create a fire risk. In fact, it is this excess heat running through the circuit that causes the breaker to trip.
Question: How we know that have to replace breaker?
Answer: 1. Breaker trips frequently.
2. Burning smell coming from the electrical panel.
3. Poorly performing appliances and light fixtures.
4. Breaker fails to stay in reset mode.
5. Visible signs of physical damage.
Question: How do I know whether to get a 15 or 20 A circuit breaker?
Answer: Calculate the total current of all electrical equipment. that want to be connected to the breaker The sum of the calculated current should not exceed 80% of the breaker capacity. For example, a 15 A breaker can be connected to external devices up to 12A (15 x 0.80 = 12), and a 20 A breaker can be connected to external devices up to 16A (20 x 0.80 = 16). This can lead to calculation errors and can cause a fire.
Chat with MISUMI
Chat service is available for any inquiry to MISUMI
Service hours
9:00 - 18:00 (Mon-Sat)
For out of service hours, you can leave a message to us.
We will reply to your inquiries on the next business day.
(except Sundays and public holidays).
Noted for use
Chat service is for Corporate customers and limited for Thai language.
Request for Quotation and Place Order is not available on Chat.
How can we improve?
How can we improve?