(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.

    Sales
  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart Item(s)
X
Loading...
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.
  • แจ้งวันหยุดทำการในเดือน กรกฎาคมและสิงหาคม 2567 | Notice holiday in July and August 2024 > คลิก

Circuit Breakers (Low Capacity)

Circuit Breakers (Low Capacity) products from the Electrical & Controls category can be selected based on many product specifications such as Rated Braking Capacity at Rated Voltage of VDC 250, Rated Current, Dimension height, Dimension width, Dimension depth. The recommended brands for Circuit Breakers (Low Capacity) are MISUMI, ABB, CHINT. The products of Circuit Breakers (Low Capacity) are offered in a total of 3 items and the product details can easily be compared. Parts and equipment for controlling machines and electrical systems. Controllers and power supplies. Wide range variety of product, on time delivery free of charge and no minimum order.
CAD
Days to Ship
  • All
  • Same day
  • 2 Day(s) or Less
  • 3 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • Others
3 items
Sort By
30
60
90
  1. 1
  • You can add up to 6 items per a category to the compare list.
    ABB Residual Current Circuit Breaker with Overcurrent Protection (RCBO) DS201 Series

    ABB Residual Current Circuit Breaker with Overcurrent Protection (RCBO) DS201 Series

    ABB

    The DS201 series is a 1P+N RCBO in two-modules width for the protection of end user single-phase circuits against overload and short-circuit currents; protection against the effects of sinusoidal alternating earth fault currents; protection against indirect contacts and additional protection against direct contacts.
    From: ฿ 3,983.33
    Days to Ship: day to ship 8 Day(s)
    day to ship 8 Day(s)
  • You can add up to 6 items per a category to the compare list.
    ABB Residual Current Circuit Breaker with Overcurrent Protection (RCBO) DSE201 M Series

    ABB Residual Current Circuit Breaker with Overcurrent Protection (RCBO) DSE201 M Series

    ABB

    DSE201 M, unique solution

    Distinctive features:
    With its breaking capacity of 10kA in only one module width and 115mm height, DSE201 M series is the perfect solution for a complete protection in commercial and industrial applications, where space optimization is particularly required.
    The unique earth fault indicator window identifies any earth fault trip, making easier the troubleshooting on the network and reducing the downtime for maintenance.
    From: ฿ 3,333.33
    Days to Ship: day to ship 8 Day(s)
    day to ship 8 Day(s)
  • You can add up to 6 items per a category to the compare list.
    ABB Residual Current Circuit Breaker with Overcurrent Protection (RCBO) DSE201 Series

    ABB Residual Current Circuit Breaker with Overcurrent Protection (RCBO) DSE201 Series

    ABB

    DSE201: The importance of simplicity
    Smart solutions for easier and safer installation in residential and light commercial applications

    With its breaking capacity of 6kA in only one module width and 100mm height, the DSE201 series is the perfect solution for a complete protection in residential and light commercial applications. The series has been renewed with the introduction of rated current 40A and 50A, to cover all the possible different applications. At home or in the office or in a shop, these devices are essential for the safety of people, utilities and equipment, protecting not only against earth fault residual currents - due to loss of isolation or accidental contact with live parts - but also against overcurrents. The DSE201 series is particularly compact, flexible and easy to install, either in consumer units or in distribution boards.
    From: ฿ 2,600.00
    Days to Ship: day to ship 76 Day(s)
    day to ship 76 Day(s)
Brand
Product Series
From
Days to Ship
Ampere frame
Rated block capacity AC 100 V(kA)
Rated block capacity AC 200 V(kA)
Rated block capacity AC 400 V(kA)
Rated Braking Capacity at Rated Voltage of VDC 250(kA)
Rated block capacity, voltages except VAC 100/200/400, VDC 250
Number of Poles
Rated Current(A)
Mounting Method
Connection Method
Representative Standard
Dimension height(mm)
Dimension width(mm)
Dimension depth(mm)
You can add up to 6 items per a category to the compare list.
ABB Residual Current Circuit Breaker with Overcurrent Protection (RCBO) DS201 Series
You can add up to 6 items per a category to the compare list.
ABB Residual Current Circuit Breaker with Overcurrent Protection (RCBO) DSE201 M Series
You can add up to 6 items per a category to the compare list.
ABB Residual Current Circuit Breaker with Overcurrent Protection (RCBO) DSE201 Series
Brand

ABB

ABB

ABB

Product Series

ABB Residual Current Circuit Breaker with Overcurrent Protection (RCBO) DS201 Series

ABB Residual Current Circuit Breaker with Overcurrent Protection (RCBO) DSE201 M Series

ABB Residual Current Circuit Breaker with Overcurrent Protection (RCBO) DSE201 Series

From

฿ 3,983.33

฿ 3,333.33

฿ 2,600.00

Days to Ship 8 Day(s) 8 Day(s) 76 Day(s)
Ampere frame---
Rated block capacity AC 100 V(kA)---
Rated block capacity AC 200 V(kA)---
Rated block capacity AC 400 V(kA)---
Rated Braking Capacity at Rated Voltage of VDC 250(kA)acc. to IEC 60898-1 240 Vacc. to IEC 60898-1 240 Vacc. to IEC 60898-1 240 V
Rated block capacity, voltages except VAC 100/200/400, VDC 250---
Number of Poles---
Rated Current(A)6 ~ 406 ~ 506 ~ 50
Mounting Method---
Connection Method---
Representative Standard---
Dimension height(mm)85115100 ~ 115
Dimension width(mm)351818
Dimension depth(mm)696969

Loading...

  1. 1

Related Categories to Circuit Breakers (Low Capacity)

FAQ Circuit Breakers (Low Capacity)

Question: Types of circuit breaker and their applications.
Answer: Circuit breakers mainly are categorized based on application as per voltage.
1. Low Voltage Circuit Breaker
Low-voltage circuit breakers are typically used in applications such as lighting circuits, motor control centers, feeder circuits, and any application in which electrical power needs to be turned on and off and overcurrent protection is required.
2. Medium Voltage Circuit Breakers
Medium voltage breakers are designed to be operated electrically by a closing solenoid or a stored energy mechanism. Manual operation is used primarily for breaker maintenance.
3. HIGH-VOLTAGE CIRCUIT BREAKERS
High-voltage circuit breakers are mechanical switching devices that connect and break current circuits (operating currents and fault currents) and carry the nominal current in the closed position.
Question: What can cause the main circuit breaker to trip?
Answer: The most common cause of a tripped circuit breaker is an overload in that circuit. Each circuit is only intended to carry a certain electrical load, and if it exceeds this load, it will cause the breaker to trip. This is important, as overloading a circuit can cause the wiring to heat up and potentially create a fire risk. In fact, it is this excess heat running through the circuit that causes the breaker to trip.
Question: How we know that have to replace breaker?
Answer: 1. Breaker trips frequently.
2. Burning smell coming from the electrical panel.
3. Poorly performing appliances and light fixtures.
4. Breaker fails to stay in reset mode.
5. Visible signs of physical damage.
Question: How do I know whether to get a 15 or 20 A circuit breaker?
Answer: Calculate the total current of all electrical equipment. that want to be connected to the breaker The sum of the calculated current should not exceed 80% of the breaker capacity. For example, a 15 A breaker can be connected to external devices up to 12A (15 x 0.80 = 12), and a 20 A breaker can be connected to external devices up to 16A (20 x 0.80 = 16). This can lead to calculation errors and can cause a fire.