(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.
Select part number to Order Now/ Add to Cart
• Up to six gages can be connected to one unit, extendable up to 10 units (60 gages at maximum) using the RS Link function to facilitate the configuration of a multi-point measurement system.
• A range of output modes to choose from: I/O output for tolerance judgment and segment output, BCD data output and RS-232C output are available.
• Other than normal measurement, peak measurement or differential measurement between gages are available.
Part Number |
---|
542-063 |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | Mass | Resolution | Maximum input frequency | Applicable input | Applicable gage head |
---|---|---|---|---|---|---|---|---|---|---|
฿ 46,317.00 ฿ 32,695.17 | 6CHANNEL INPUT COUNTER | 1 Piece(s) | 2 Day(s) | Approx. 910g | 10µm (±999999.99mm) / .0005" (±9999.9995") / 5µm (±999999.995mm) / .00005" (±999.99995") / 0.5µm (±9999.9995mm) / .000005" (±.99.999995") / [Parameter set] | 1.25MHz (2-phase square wave) / response speed depends on gage specification / Max. counting speed: 5MHz | Differential square-wave | LGE / LGF / LGK / LGB / LGM / LG Models with reference point mark, sine wave output type are excluded. |
Loading...
Product Model | Linear Scale (Measuring Unit) | Quantizing error | ±1 count | Operating temperature (humidity) range | 0 to 40°C (RH 20 to 80%, no condensation) |
---|---|---|---|---|---|
Storage temperature (humidity) range | –10 to 50°C (RH 20 to 80%, no condensation) | Standard Accessories | Fixing foot (4) / connecting bracket (4) / fixing screw M4×12 (8) | External dimensions | 144 (W) × 72 (H) ×139 (D) mm |
Rating Power Supply | 12 - 24V DC / terminal block (M3 screw) | Rating Power consumption | 8.4W or less (700mA max.) Ensure at least 1A is available per unit. | Number of input channels | 6 |
LED display | 8 digits for parameter display (displays settings) / 1 for error display | Error message | Overspeed / gage error etc. | External display | Dedicated external display unit D-EV (optional) can be connected. |
Number of input switches | 4 | Function of input switches | Measurement mode switching / parameter setting | Input/output Tolerance judgment output | 1 to 6 channels (L1, L2, L3) / open-collector |
Input/output BCD output | Parallel BCD output (positive/negative-true logic) / open-collector | Input/output Segment output | Function to set on only the terminals corresponding to the counting values / open-collector | Input/output Control output | Normal operation signal (NOM) / open-collector |
Input/output Control input | Output channel designation (segment, in the BCD mode), presetting, peak value clear, range changeover (at segment output), holding counting value open-collector or no-voltage contact signal (with/without contact point) | Interface RS-232C | Measurement data output and control inputEIA RS-232C-compatibleUse cross cables for home position, DTE (terminal definition). | Interface RS link | Max. connecting unit: 10 (6 when using EF counter)Connecting cable length: Max. 10m (sum of link cable length)Data transfer time: 1sec./60ch (when transmission rate is 19200bps) |
Please check the type/dimensions/specifications of the part 542-063 in the 542 series 6channel input counter EV-16P/Z/D series.
Part Number |
---|
542-064 |
542-067 |
Part Number | Price | Minimum Order Qty | Volume Discount | Days to Ship | Mass | Resolution | Maximum input frequency | Applicable input | Applicable gage head |
---|---|---|---|---|---|---|---|---|---|
฿ 37,934.00 | 1 Piece(s) | 2 Day(s) | Approx. 830g | Depends on gage specification. | Response speed depends on gage specification. | Digimatic code (SPC) | LGD / LGS | ||
฿ 47,934.00 | 1 Piece(s) | 50 Day(s) | Approx. 910g | 10µm (±999999.99mm) / .0005" (±9999.9995") / 5µm (±999999.995mm) / .00005" (±999.99995") / 1µm (±99999.999mm) / .00005" (±999.99995") / 0.5µm (±9999.9995mm) / .000005" (±.99.999995") / [Parameter set] | 1.25MHz (2-phase square wave) / response speed depends on gage specification / Max. counting speed: 5MHz | Differential square-wave | LGF with reference point mark |
How can we improve?