1. No. of part number of this product, can see and select from the list here
2. Or select spec by configure tab until part number generated
3. Product information available in this area

(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.

    Sales
  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart Item(s)
X
Loading...
  • แจ้งวันหยุดทำการในเดือน กรกฎาคมและสิงหาคม 2567 | Notice holiday in July and August 2024 > คลิก

Tempilstik (Temperature Indicator) (Part Number)

Tempilstik (Temperature Indicator)
You can add up to 6 items per a category to the compare list.

Part Number :
  • From :
    ฿ 2,083.00/Unit
  • Qty :
  • Days to Ship :
    ---
  • Total Price :
    ---

Select part number to Order Now/ Add to Cart

Product Description

A chalk-form product that contains chemicals with a known melting point. It fuses when the temperature displayed on the case is reached.

Part Number
TSC0482
TSC0500
TSC0510
TSC0538
TSC0550
TSC0560
TSC0566
TSC0593
TSC0600
TSC0621
TSC0625
TSC0649
TSC0677
TSC0700
TSC0704
TSC0760
TSC0788
TSC0816
TSC0843
TSC0871
TSC0899
TSC0927
TSC0982
TSC1038
TSC1066
TSC1093
Part NumberPriceNameMinimum Order Qty.Volume DiscountDays to ShipIndicated Temperature
(°C)
Indicated Temperature
(°F)

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 482900

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 500932

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 510950

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 5381000

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 5501022

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 5601040

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 5661050

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 5931100

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 6001112

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 6211150

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 6251157

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 6491200

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 6771250

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 7001292

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 7041300

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 7601400

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 7881450

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 8161500

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 8431550

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 8711600

฿ 2,389.00

TMP TENPIL STIK 1 Piece(s) 11 Day(s) 8991650

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 9271700

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 9821800

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 10381900

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 10661950

฿ 999,999,999.00

TMP TENPIL STIK 1 Piece(s) Quote 10932000

Loading...

Basic Information

Product Model Other Features 1 Complies with the temperature requirements of WS D1.1: ASME Code, Section I, III and VIII: ANSI/ASME Code B31.1 and 31.3. Features 2 Indicated temperature error is guaranteed to be within ± 1% of indicated temperature.
Features 3 It does not employ lead, sulfur etc. as main ingredients. Features 4 Highly dense for a longer life compared to other manufacturer products. Features 5 Specified temperature can be distinguished because of color coding based on various temperatures.
Features 6 Holder holds the Tempilstik firmly and does not slip during work. Features 7 Temperature certificate can be issued. Use General temperature during welding, temperature for heat treatments such as hardening, quenching, and tempering, temperature for silver brazing, soft soldering, etc., interpass temperature during steel welding, welding temperature for nuclear power plant parts, welding of pipes, temperature during residual stress removal, annealing, temperature for forging, temperature for drawing process, temperature of punching die.
Usage Method Let Tempilstik touch the heated or heating item. If the Tempilstik melts, the user knows the measurement surface is higher than indicating temperature, and it doesn't melt, it is lower than that. Using 2 pieces of Tempilstik which each indicate different temperatures, temperature ranges can be measured accurately. Responds to Inter-path Temperatures Prepare Tempilstiks that correspond to the minimum and maximum welding temperatures of the metal to be welded. Check the intersection point 10 mm from the shoulder of the groove and the center of the weld length with two kinds of Tempilstiks. The optimal preheating temperature are where the lowest temperature choke melts and the highest temperature choke does not melt. For the interpass temperature, after the first pass, the temperature of the base material rises and the highest temperature choke melts. The optimum temperature for starting the second pass is the state where after some cooling time, the lowest temperature choke melts while the highest temperature choke does not melt.