(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.
Select part number to Order Now/ Add to Cart
EasyPact CVS range is the easy choice for quality and value.
Designed to meet the requirements of the majority of common protection applications in small to medium-sized buildings, EasyPact CVS circuit breakers deliver a high level of performance and cost-saving functionality that is unusual in their price range.
- Rated current from 16 to 630 A
- Breaking capacity from 25 to 50 kA at 400/415 V
- 3 and 4 pole versions
- 3 frame sizes
- Thermal-magnetic and electronic protection available for the entire range
- Extended, adjustable thermal protection from 0.7 to 1 times (TMD) or 0.5 to 1 times (electronic) the rating of the trip unit
- Common accessories and auxiliaries with other Schneider Electric MCCB offers
- Suitable for isolation
- Earth-leakage protection by associated Vigi Module
- Switch-disconnector versions also available
- Compliance with international standards: IEC 60947-2, CCC, EAC and other local certifications
- Green Premium product
Part Number |
---|
LV525301 |
LV525302 |
LV525303 |
LV525322 |
LV525323 |
LV525331 |
LV525332 |
LV525333 |
LV525342 |
LV525343 |
LV525352 |
LV525353 |
LV525425 |
LV525426 |
LV525439 |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | RoHS | Ampere frame | Number of Poles | Rated Current (A) | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Range | Type | Trip Unit | Breaking Capacity at 380/415 V (kA) | Rated Operational Current |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 3,684.38 | CIRCUIT BREAKER | 1 Piece(s) | 45 Day(s) | 10 | 200AF to 399AF | 3 | 160 | - | - | - | - | - | With TM-D Thermal-Magnetic | 25 | - | ||
฿ 3,684.38 | CIRCUIT BREAKER | 1 Piece(s) | Same day | 10 | 200AF to 399AF | 3 | 200 | - | - | - | - | - | With TM-D Thermal-Magnetic | 25 | - | ||
฿ 3,684.38 | CIRCUIT BREAKER | 1 Piece(s) | Same day | 10 | 200AF to 399AF | 3 | 250 | - | - | - | - | - | With TM-D Thermal-Magnetic | 25 | - | ||
฿ 4,947.19 | CIRCUIT BREAKER LOW CAPACITY | 1 Piece(s) | 90 Day(s) | 10 | 200AF to 399AF | 4 | 200 | - | - | - | - | - | With TM-D Thermal-Magnetic | 25 | - | ||
฿ 4,947.19 | CIRCUIT BREAKER LOW CAPACITY | 1 Piece(s) | 90 Day(s) | 10 | 200AF to 399AF | 4 | 250 | - | - | - | - | - | With TM-D Thermal-Magnetic | 25 | - | ||
฿ 5,144.06 | CIRCUIT BREAKER | 1 Piece(s) | 45 Day(s) | 10 | 200AF to 399AF | 3 | 160 | - | - | - | - | - | With TM-D Thermal-Magnetic | 36 | - | ||
฿ 5,144.06 | CIRCUIT BREAKER | 1 Piece(s) | 45 Day(s) | 10 | 200AF to 399AF | 3 | 200 | - | - | - | - | - | With TM-D Thermal-Magnetic | 36 | - | ||
฿ 5,144.06 | CIRCUIT BREAKER | 1 Piece(s) | Same day | 10 | 200AF to 399AF | 3 | 250 | - | - | - | - | - | With TM-D Thermal-Magnetic | 36 | - | ||
฿ 6,440.63 | CIRCUIT BREAKER LOW CAPACITY | 1 Piece(s) | 90 Day(s) | 10 | 200AF to 399AF | 4 | 200 | - | - | - | - | - | With TM-D Thermal-Magnetic | 36 | - | ||
฿ 6,440.63 | CIRCUIT BREAKER LOW CAPACITY | 1 Piece(s) | 90 Day(s) | 10 | 200AF to 399AF | 4 | 250 | - | - | - | - | - | With TM-D Thermal-Magnetic | 36 | - | ||
฿ 6,778.13 | CIRCUIT BREAKER LOW CAPACITY | 1 Piece(s) | 90 Day(s) | 10 | 200AF to 399AF | 4 | 200 | - | - | - | - | - | With TM-D Thermal-Magnetic | 36 | - | ||
฿ 6,778.13 | CIRCUIT BREAKER LOW CAPACITY | 1 Piece(s) | 90 Day(s) | 10 | 200AF to 399AF | 4 | 250 | - | - | - | - | - | With TM-D Thermal-Magnetic | 36 | - | ||
฿ 3,344.06 | SWITCH DISCONNECTOR | 1 Piece(s) | 90 Day(s) | 10 | 200AF to 399AF | 3 | - | 161 | 105 | 86 | - | - | - | - | AC-22A, AC-23A | ||
฿ 4,460.63 | SWITCH DISCONNECTOR | 1 Piece(s) | 90 Day(s) | 10 | 200AF to 399AF | 4 | - | 161 | 140 | 86 | - | - | - | - | AC-22A, AC-23A | ||
฿ 4,421.25 | CIRCUIT BREAKER LOW CAPACITY | 1 Piece(s) | 90 Day(s) | 10 | 200AF to 399AF | 3 | 220 | - | - | - | - | - | With MA | 36 | - |
Loading...
Rated block capacity AC 100 V(kA) | - | Rated block capacity AC 200 V(kA) | - | Rated block capacity AC 400 V(kA) | - |
---|---|---|---|---|---|
Rated Braking Capacity at Rated Voltage of VDC 250(kA) | - | Earth Leakage Protection | No |
How can we improve?
How can we improve?