Standard Control Unit

Brand :
SCHNEIDER
Caution
Product Description
Standard Control Unit Luca, Class 10, 8...32 A, 110...220 V DC/ac
| Product Code | Range of product | Product or component type | Device short name | Product specific application | Vibration resistance | Shock resistance | Fixing mode | Width | Height | Depth | Net weight | IP degree of protection | Standards | Ambient air temperature for operation | Ambient air temperature for storage | Product certifications | Sustainable offer status | EU RoHS Directive | Mercury free | RoHS exemption information | China RoHS Regulation | Environmental Disclosure | Circularity Profile | WEEE | Operating altitude | Resistance to electrostatic discharge | Warranty | Motor power kW | Utilisation category | Network frequency | [Uc] control circuit voltage | Compatibility code | Range | [Ue] rated operational voltage | [Ui] rated insulation voltage | Product compatibility | [Uimp] rated impulse withstand voltage | Protective treatment | Product name | Device application | Main function available | Resistance to fast transients | Resistance to radiated fields | Immunity to microbreaks | Control circuit voltage limits | Operating time | Heat dissipation | Fire resistance | Phase failure sensitivity | Thermal overload class | Tripping threshold | Load type | Rated motor current adjustment range | Typical current consumption | Safe separation of circuit | Immunity to radioelectric fields | Immunity to voltage dips | Non‑dissipating shock wave |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LUCA32FU | TeSys U | Standard control unit | LUCA | Basic protection requirements for motor starters: overload and short‑circuit | 2 gn, 5 to 300 Hz, power poles open conforming to IEC 60068‑2‑6 4 gn, 5 to 300 Hz, power poles closed conforming to IEC 60068‑2‑6 | 10 gn power poles open conforming to IEC 60068‑2‑27 15 gn power poles closed conforming to IEC 60068‑2‑27 | Plug‑in (front face) | 45 mm | 66 mm | 60 mm | 0.135 kg | IP20 front panel and wired terminals conforming to IEC 60947‑1 IP20 other faces conforming to IEC 60947‑1 IP40 front panel outside connection zone conforming to IEC 60947‑1 | EN 60947‑6‑2 IEC 60947‑6‑2 UL 60947‑4‑1, with phase barrier CSA C22.2 No 60947‑4‑1, with phase barrier | ‑25 to 70 °C | ‑40 to 85 °C | CE UL CSA CCC EAC ASEFA ATEX Marine | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | End of Life Information | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 2000 m | 8 kV level 3 in open air conforming to IEC 61000‑4‑2 8 kV level 4 on contact conforming to IEC 61000‑4‑2 | 18 months | 15 kW at 400...440 V AC 50/60 Hz 15 kW at 500 V AC 50/60 Hz 18.5 kW at 690 V AC 50/60 Hz | AC‑43 AC‑41 AC‑44 | 40...60 Hz | 110...240 V AC 110...220 V DC | LUCA | TeSys | 690 V AC | 690 V conforming to IEC 60947‑6‑2 600 V conforming to UL 60947‑4‑1 600 V conforming to CSA C22.2 No 60947‑4‑1 | Power base LUB32 Power base LUB38 Power base LUB320 Power base LUB380 Reversing contactor breaker LU2B32FU Reversing contactor breaker LU2B38FU | IEC 60947‑6‑2 6 kV | TH conforming to IEC 60068 | TeSys U | Motor control Motor protection | Earth fault protection Protection against phase failure and phase imbalance Protection against overload and short‑circuit Manual reset | 2 kV class 3 serial link conforming to IEC 61000‑4‑4 4 kV class 4 all circuits except for serial link conforming to IEC 61000‑4‑4 | 10 V/m 3 conforming to IEC 61000‑4‑3 | 3 ms | 88...264 V for AC circuit 110...240 V in operation 88...242 V for DC circuit 110...220 V in operation 55 V for AC circuit 110...240 V drop‑out 55 V for DC circuit 110...220 V drop‑out | 35 ms opening with LUB32 for control circuit 35 ms opening with LUB38 for control circuit 50 ms closing with LUB32 for control circuit 50 ms closing with LUB38 for control circuit | 3 W for control circuit with LUB32 3 W for control circuit with LUB38 | 960 °C parts supporting live components conforming to IEC 60695‑2‑12 650 °C conforming to IEC 60695‑2‑12 | Yes | Class 10 ‑ frequency limit: 40 to 60 Hz ‑ temperature compensation: ‑25 to 70 °C conforming to IEC 60947‑6‑2 Class 10 ‑ frequency limit: 40 to 60 Hz ‑ temperature compensation: ‑25 to 70 °C conforming to UL 508 | 14.2 x Ir +/‑ 20 % | 3‑phase motor ‑ cooling: self‑cooled | 8 to 32 A | 280 mA at 110...240 V AC I maximum while closing with LUB32 280 mA at 110...240 V AC I maximum while closing with LUB38 280 mA at 110...220 V DC I maximum while closing with LUB32 280 mA at 110...220 V DC I maximum while closing with LUB38 25 mA at 110...240 V AC I rms sealed with LUB32 25 mA at 110...240 V AC I rms sealed with LUB38 25 mA at 110...220 V DC I rms sealed with LUB32 25 mA at 110...220 V DC I rms sealed with LUB38 | 400 V SELV between the control and auxiliary circuits conforming to IEC 60947‑1 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947‑1 | 10 V conforming to IEC 61000‑4‑6 | 70 % / 500 ms conforming to IEC 61000‑4‑11 | 1 kV serial mode conforming to IEC 60947‑6‑2 2 kV common mode conforming to IEC 60947‑6‑2 |