Select part number to Order Now/ Add to Cart
Complete illuminated Selector Switch Ø22
Product Code | Range of product | Product or component type | Device short name | [Us] rated supply voltage | Vibration resistance | Shock resistance | Electrical durability | Mechanical durability | Service life | IP degree of protection | NEMA degree of protection | Standards | Ambient air temperature for operation | Ambient air temperature for storage | Product certifications | Supply voltage limits | Resistance to electrostatic discharge | Current consumption | Tightening torque | Signalling type | Sale per indivisible quantity | Bulb base | [Ui] rated insulation voltage | [Ith] conventional free air thermal current | IK degree of protection | Mounting diameter | Light source | Contacts type and composition | Connections - terminals | Bezel material | Short-circuit protection | Contact operation | Positive opening | Protective treatment | Electrical shock protection class | Type of operator | Shape of signaling unit head | Operator profile | Contacts material | Fixing collar material | Device presentation | Operator position information | Resistance to high pressure washer | Contacts usage | Operating torque | Shape of screw head | [Ie] rated operational current | Electrical reliability | Surge withstand | Resistance to fast transients | Resistance to electromagnetic fields | Electromagnetic emission | Sustainable offer status | EU RoHS Directive | Mercury free | RoHS exemption information | China RoHS Regulation | Environmental Disclosure | Circularity Profile | WEEE | REACH Regulation | REACH free of SVHC | Warranty | [Uimp] rated impulse withstand voltage | Head type | Width | Height | Depth | Net weight | Terminals description ISO n°1 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XB4BK121M5 | Harmony XB4 | Illuminated selector switch | XB4 | 24 V AC/DC at 50/60 Hz | 5 gn (f= 2 to 500 Hz) conforming to IEC 60068-2-6 | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C | 1000000 cycles | 100000 h at rated voltage and 25 ℃ | IP66 conforming to IEC 60529 IP67 IP69 IP69K | NEMA 13 NEMA 4X | EN/IEC 60947-5-5 JIS C8201-5-1 CSA C22.2 No 14 EN/IEC 60947-1 UL 508 EN/IEC 60947-5-1 EN/IEC 60947-5-4 JIS C8201-1 | -40 to 70 ℃ | -40 to 70 ℃ | LROS (Lloyds register of shipping) RINA GL BV CSA DNV UL | 19.2 to 30 V DC 21.6 to 26.4 V AC | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 | 18 mA | 0.8 to 1.2 N.m conforming to EN 60947-1 | Steady | 1 | Integral LED | 600 V (pollution degree 3) conforming to EN 60947-1 | 10 A conforming to EN/IEC 60947-5-1 | IK06 conforming to IEC 50102 | 22 mm | Protected LED | 1 NO + 1 NC | Screw clamp terminals, <= 2 x 1.5 mm2 with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm2 without cable end conforming to EN/IEC 60947-1 | Chromium plated metal | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | Slow-break | With conforming to EN/IEC 60947-5-1 appendix K | TH | Class I conforming to IEC 60536 | Stay put | Round | White standard handle | Silver alloy (Ag/Ni) | Zamak | Complete product | 2 positions 90° | 7000000 Pa at 55 ℃, distance : 0.1 m | Standard contacts | 0.14 N.m NO changing electrical state | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 | 1 kV conforming to IEC 61000-4-5 | 2 kV conforming to IEC 61000-4-4 | 10 V/m conforming to IEC 61000-4-3 | Class B conforming to IEC 55011 | - | - | - | - | - | - | - | - | - | - | - | - | - | 30 mm | 47 mm | 68 mm | 0.111 kg | (13-14)NO (21-22)NC |
XB4BK124G5 | Harmony XB4 | Illuminated selector switch | XB4 | 110...120 V AC at 50/60 Hz | 5 gn (f= 2 to 500 Hz) conforming to IEC 60068-2-6 | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C | 1000000 cycles | 100000 h at rated voltage and 25 ℃ | IP66 conforming to IEC 60529 IP67 IP69 IP69K | NEMA 13 NEMA 4X | EN/IEC 60947-5-4 EN/IEC 60947-1 JIS C8201-5-1 UL 508 EN/IEC 60947-5-5 CSA C22.2 No 14 EN/IEC 60947-5-1 JIS C8201-1 | -40 to 70 ℃ | -40 to 70 ℃ | UL BV GL LROS (Lloyds register of shipping) CSA DNV RINA | 100 to 132 V AC | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 | 14 mA | 0.8 to 1.2 N.m conforming to EN 60947-1 | Steady | 1 | Integral LED | 600 V (pollution degree 3) conforming to EN 60947-1 | 10 A conforming to EN/IEC 60947-5-1 | IK06 conforming to IEC 50102 | 22 mm | Protected LED | 1 NO + 1 NC | Screw clamp terminals, <= 2 x 1.5 mm2 with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm2 without cable end conforming to EN/IEC 60947-1 | Chromium plated metal | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | Slow-break | With conforming to EN/IEC 60947-5-1 appendix K | TH | Class I conforming to IEC 60536 | Stay put | Round | Red standard handle | Silver alloy (Ag/Ni) | Zamak | Complete product | 2 positions 90° | 7000000 Pa at 55 ℃, distance : 0.1 m | Standard contacts | 0.14 N.m NO changing electrical state | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 | 1 kV conforming to IEC 61000-4-5 | 2 kV conforming to IEC 61000-4-4 | 10 V/m conforming to IEC 61000-4-3 | Class B conforming to IEC 55011 | Green Premium product | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | End of Life Information | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | REACH Declaration | Yes | 18 months | 6 kV EN 60947-1 | Standard | 30 mm | 47 mm | 68 mm | 0.111 kg | (21-22)NC (13-14)NO |
XB4BK131M5 | Harmony XB4 | Illuminated selector switch | XB4 | 24 V AC/DC at 50/60 Hz | 5 gn (f= 2 to 500 Hz) conforming to IEC 60068-2-6 | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C | 1000000 cycles | 100000 h at rated voltage and 25 ℃ | IP66 conforming to IEC 60529 IP67 IP69 IP69K | NEMA 13 NEMA 4X | EN/IEC 60947-5-4 EN/IEC 60947-1 EN/IEC 60947-5-1 EN/IEC 60947-5-5 CSA C22.2 No 14 UL 508 JIS C8201-5-1 JIS C8201-1 | -40 to 70 ℃ | -40 to 70 ℃ | GL LROS (Lloyds register of shipping) DNV RINA CSA UL BV | 19.2 to 30 V DC 21.6 to 26.4 V AC | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 | 18 mA | 0.8 to 1.2 N.m conforming to EN 60947-1 | Steady | 1 | Integral LED | 600 V (pollution degree 3) conforming to EN 60947-1 | 10 A conforming to EN/IEC 60947-5-1 | IK06 conforming to IEC 50102 | 22 mm | Protected LED | 1 NO + 1 NC | Screw clamp terminals, <= 2 x 1.5 mm2 with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm2 without cable end conforming to EN/IEC 60947-1 | Chromium plated metal | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | Slow-break | With conforming to EN/IEC 60947-5-1 appendix K | TH | Class I conforming to IEC 60536 | Stay put | Round | White standard handle | Silver alloy (Ag/Ni) | Zamak | Complete product | 3 positions +/- 45° | 7000000 Pa at 55 ℃, distance : 0.1 m | Standard contacts | 0.14 N.m NO changing electrical state | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 | 1 kV conforming to IEC 61000-4-5 | 2 kV conforming to IEC 61000-4-4 | 10 V/m conforming to IEC 61000-4-3 | Class B conforming to IEC 55011 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
XB4BK133B5 | Harmony XB4 | Illuminated selector switch | XB4 | 24 V AC/DC at 50/60 Hz | 5 gn (f= 2 to 500 Hz) conforming to IEC 60068-2-6 | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C | 1000000 cycles | 100000 h at rated voltage and 25 ℃ | IP66 conforming to IEC 60529 IP67 IP69 IP69K | NEMA 13 NEMA 4X | UL 508 EN/IEC 60947-5-4 JIS C8201-5-1 EN/IEC 60947-5-5 EN/IEC 60947-5-1 CSA C22.2 No 14 EN/IEC 60947-1 JIS C8201-1 | -40 to 70 ℃ | -40 to 70 ℃ | RINA CSA UL GL LROS (Lloyds register of shipping) BV DNV | 19.2 to 30 V DC 21.6 to 26.4 V AC | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 | 18 mA | 0.8 to 1.2 N.m conforming to EN 60947-1 | Steady | 1 | Integral LED | 600 V (pollution degree 3) conforming to EN 60947-1 | 10 A conforming to EN/IEC 60947-5-1 | IK06 conforming to IEC 50102 | 22 mm | Protected LED | 1 NO + 1 NC | Screw clamp terminals, <= 2 x 1.5 mm2 with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm2 without cable end conforming to EN/IEC 60947-1 | Chromium plated metal | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | Slow-break | With conforming to EN/IEC 60947-5-1 appendix K | TH | Class I conforming to IEC 60536 | Stay put | Round | Green standard handle | Silver alloy (Ag/Ni) | Zamak | Complete product | 3 positions +/- 45° | 7000000 Pa at 55 ℃, distance : 0.1 m | Standard contacts | 0.14 N.m NO changing electrical state | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 | 1 kV conforming to IEC 61000-4-5 | 2 kV conforming to IEC 61000-4-4 | 10 V/m conforming to IEC 61000-4-3 | Class B conforming to IEC 55011 | Green Premium product | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | End of Life Information | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | REACH Declaration | Yes | 18 months | EN 60947-1 6 kV | Standard | - | - | - | - | - |
XB4BK133M5 | Harmony XB4 | Illuminated selector switch | XB4 | 230...240 V AC at 50/60 Hz | 5 gn (f= 2 to 500 Hz) conforming to IEC 60068-2-6 | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C | 1000000 cycles | 100000 h at rated voltage and 25 ℃ | IP66 conforming to IEC 60529 IP67 IP69 IP69K | NEMA 13 NEMA 4X | UL 508 CSA C22.2 No 14 EN/IEC 60947-5-1 EN/IEC 60947-1 JIS C8201-5-1 EN/IEC 60947-5-4 EN/IEC 60947-5-5 JIS C8201-1 | -40 to 70 ℃ | -40 to 70 ℃ | CSA BV DNV LROS (Lloyds register of shipping) RINA UL GL | 195 to 264 V AC | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 | 14 mA | 0.8 to 1.2 N.m conforming to EN 60947-1 | Steady | 1 | Integral LED | 600 V (pollution degree 3) conforming to EN 60947-1 | 10 A conforming to EN/IEC 60947-5-1 | IK06 conforming to IEC 50102 | 22 mm | Protected LED | 1 NO + 1 NC | Screw clamp terminals, <= 2 x 1.5 mm2 with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm2 without cable end conforming to EN/IEC 60947-1 | Chromium plated metal | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | Slow-break | With conforming to EN/IEC 60947-5-1 appendix K | TH | Class I conforming to IEC 60536 | Stay put | Round | Green standard handle | Silver alloy (Ag/Ni) | Zamak | Complete product | 3 positions +/- 45° | 7000000 Pa at 55 ℃, distance : 0.1 m | Standard contacts | 0.14 N.m NO changing electrical state | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 | 1 kV conforming to IEC 61000-4-5 | 2 kV conforming to IEC 61000-4-4 | 10 V/m conforming to IEC 61000-4-3 | Class B conforming to IEC 55011 | Green Premium product | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | End of Life Information | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | REACH Declaration | Yes | 18 months | 6 kV EN 60947-1 | Standard | - | - | - | - | - |
XB4BK134M5 | Harmony XB4 | Illuminated selector switch | XB4 | 230...240 V AC at 50/60 Hz | 5 gn (f= 2 to 500 Hz) conforming to IEC 60068-2-6 | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C | 1000000 cycles | 100000 h at rated voltage and 25 ℃ | IP66 conforming to IEC 60529 IP67 IP69 IP69K | NEMA 13 NEMA 4X | EN/IEC 60947-1 EN/IEC 60947-5-4 EN/IEC 60947-5-1 EN/IEC 60947-5-5 CSA C22.2 No 14 JIS C8201-5-1 UL 508 JIS C8201-1 | -40 to 70 ℃ | -40 to 70 ℃ | DNV GL CSA BV UL LROS (Lloyds register of shipping) RINA | 195 to 264 V AC | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 | 14 mA | 0.8 to 1.2 N.m conforming to EN 60947-1 | Steady | 1 | Integral LED | 600 V (pollution degree 3) conforming to EN 60947-1 | 10 A conforming to EN/IEC 60947-5-1 | IK06 conforming to IEC 50102 | 22 mm | Protected LED | 1 NO + 1 NC | Screw clamp terminals, <= 2 x 1.5 mm2 with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm2 without cable end conforming to EN/IEC 60947-1 | Chromium plated metal | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | Slow-break | With conforming to EN/IEC 60947-5-1 appendix K | TH | Class I conforming to IEC 60536 | Stay put | Round | Red standard handle | Silver alloy (Ag/Ni) | Zamak | Complete product | 3 positions +/- 45° | 7000000 Pa at 55 ℃, distance : 0.1 m | Standard contacts | 0.14 N.m NO changing electrical state | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 | 1 kV conforming to IEC 61000-4-5 | 2 kV conforming to IEC 61000-4-4 | 10 V/m conforming to IEC 61000-4-3 | Class B conforming to IEC 55011 | Green Premium product | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | End of Life Information | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | REACH Declaration | Yes | 18 months | EN 60947-1 6 kV | Standard | - | - | - | - | - |
XB4BK135B5 | Harmony XB4 | Illuminated selector switch | XB4 | 24 V AC/DC at 50/60 Hz | 5 gn (f= 2 to 500 Hz) conforming to IEC 60068-2-6 | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C | 1000000 cycles | 100000 h at rated voltage and 25 ℃ | IP66 conforming to IEC 60529 IP67 IP69 IP69K | NEMA 13 NEMA 4X | UL 508 EN/IEC 60947-5-5 EN/IEC 60947-5-4 EN/IEC 60947-5-1 CSA C22.2 No 14 EN/IEC 60947-1 JIS C8201-5-1 JIS C8201-1 | -40 to 70 ℃ | -40 to 70 ℃ | UL CSA DNV BV RINA LROS (Lloyds register of shipping) GL | 19.2 to 30 V DC 21.6 to 26.4 V AC | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 | 18 mA | 0.8 to 1.2 N.m conforming to EN 60947-1 | Steady | 1 | Integral LED | 600 V (pollution degree 3) conforming to EN 60947-1 | 10 A conforming to EN/IEC 60947-5-1 | IK06 conforming to IEC 50102 | 22 mm | Protected LED | 1 NO + 1 NC | Screw clamp terminals, <= 2 x 1.5 mm2 with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm2 without cable end conforming to EN/IEC 60947-1 | Chromium plated metal | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | Slow-break | With conforming to EN/IEC 60947-5-1 appendix K | TH | Class I conforming to IEC 60536 | Stay put | Round | Orange standard handle | Silver alloy (Ag/Ni) | Zamak | Complete product | 3 positions +/- 45° | 7000000 Pa at 55 ℃, distance : 0.1 m | Standard contacts | 0.14 N.m NO changing electrical state | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 | 1 kV conforming to IEC 61000-4-5 | 2 kV conforming to IEC 61000-4-4 | 10 V/m conforming to IEC 61000-4-3 | Class B conforming to IEC 55011 | Green Premium product | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | End of Life Information | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | REACH Declaration | Yes | 18 months | EN 60947-1 6 kV | Standard | - | - | - | - | - |
XB4BK135M5 | Harmony XB4 | Illuminated selector switch | XB4 | 230...240 V AC at 50/60 Hz | 5 gn (f= 2 to 500 Hz) conforming to IEC 60068-2-6 | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C | 1000000 cycles | 100000 h at rated voltage and 25 ℃ | IP66 conforming to IEC 60529 IP67 IP69 IP69K | NEMA 13 NEMA 4X | EN/IEC 60947-1 UL 508 EN/IEC 60947-5-1 CSA C22.2 No 14 EN/IEC 60947-5-4 JIS C8201-5-1 EN/IEC 60947-5-5 JIS C8201-1 | -40 to 70 ℃ | -40 to 70 ℃ | DNV CSA LROS (Lloyds register of shipping) UL BV RINA GL | 195 to 264 V AC | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 | 14 mA | 0.8 to 1.2 N.m conforming to EN 60947-1 | Steady | 1 | Integral LED | 600 V (pollution degree 3) conforming to EN 60947-1 | 10 A conforming to EN/IEC 60947-5-1 | IK06 conforming to IEC 50102 | 22 mm | Protected LED | 1 NO + 1 NC | Screw clamp terminals, <= 2 x 1.5 mm2 with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm2 without cable end conforming to EN/IEC 60947-1 | Chromium plated metal | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | Slow-break | With conforming to EN/IEC 60947-5-1 appendix K | TH | Class I conforming to IEC 60536 | Stay put | Round | Orange standard handle | Silver alloy (Ag/Ni) | Zamak | Complete product | 3 positions +/- 45° | 7000000 Pa at 55 ℃, distance : 0.1 m | Standard contacts | 0.14 N.m NO changing electrical state | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 | 1 kV conforming to IEC 61000-4-5 | 2 kV conforming to IEC 61000-4-4 | 10 V/m conforming to IEC 61000-4-3 | Class B conforming to IEC 55011 | Green Premium product | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | End of Life Information | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | REACH Declaration | Yes | 18 months | EN 60947-1 6 kV | Standard | - | - | - | - | - |
XB4BK136B5 | Harmony XB4 | Illuminated selector switch | XB4 | 230...240 V AC at 50/60 Hz | 5 gn (f= 2 to 500 Hz) conforming to IEC 60068-2-6 | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C | 1000000 cycles | 100000 h at rated voltage and 25 ℃ | IP66 conforming to IEC 60529 IP67 IP69 IP69K | NEMA 13 NEMA 4X | CSA C22.2 No 14 UL 508 EN/IEC 60947-5-1 JIS C8201-5-1 EN/IEC 60947-5-5 EN/IEC 60947-1 EN/IEC 60947-5-4 JIS C8201-1 | -40 to 70 ℃ | -40 to 70 ℃ | RINA BV UL LROS (Lloyds register of shipping) CSA DNV GL | 195 to 264 V AC | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 | 14 mA | 0.8 to 1.2 N.m conforming to EN 60947-1 | Steady | 1 | Integral LED | 600 V (pollution degree 3) conforming to EN 60947-1 | 10 A conforming to EN/IEC 60947-5-1 | IK06 conforming to IEC 50102 | 22 mm | Protected LED | 1 NO + 1 NC | Screw clamp terminals, <= 2 x 1.5 mm2 with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm2 without cable end conforming to EN/IEC 60947-1 | Chromium plated metal | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | Slow-break | With conforming to EN/IEC 60947-5-1 appendix K | TH | Class I conforming to IEC 60536 | Stay put | Round | Blue standard handle | Silver alloy (Ag/Ni) | Zamak | Complete product | 3 positions +/- 45° | 7000000 Pa at 55 ℃, distance : 0.1 m | Standard contacts | 0.14 N.m NO changing electrical state | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 | 1 kV conforming to IEC 61000-4-5 | 2 kV conforming to IEC 61000-4-4 | 10 V/m conforming to IEC 61000-4-3 | Class B conforming to IEC 55011 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
XB4BK136M5 | Harmony XB4 | Illuminated selector switch | XB4 | 230...240 V AC at 50/60 Hz | 5 gn (f= 2 to 500 Hz) conforming to IEC 60068-2-6 | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C | 1000000 cycles | 100000 h at rated voltage and 25 ℃ | IP66 conforming to IEC 60529 IP67 IP69 IP69K | NEMA 13 NEMA 4X | CSA C22.2 No 14 UL 508 EN/IEC 60947-5-5 JIS C8201-5-1 EN/IEC 60947-1 EN/IEC 60947-5-4 EN/IEC 60947-5-1 JIS C8201-1 | -40 to 70 ℃ | -40 to 70 ℃ | LROS (Lloyds register of shipping) UL BV DNV CSA RINA GL | 195 to 264 V AC | 6 kV on contact (on metal parts) conforming to IEC 61000-4-2 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 | 14 mA | 0.8 to 1.2 N.m conforming to EN 60947-1 | Steady | 1 | Integral LED | 600 V (pollution degree 3) conforming to EN 60947-1 | 10 A conforming to EN/IEC 60947-5-1 | IK06 conforming to IEC 50102 | 22 mm | Protected LED | 1 NO + 1 NC | Screw clamp terminals, <= 2 x 1.5 mm2 with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm2 without cable end conforming to EN/IEC 60947-1 | Chromium plated metal | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | Slow-break | With conforming to EN/IEC 60947-5-1 appendix K | TH | Class I conforming to IEC 60536 | Stay put | Round | Blue standard handle | Silver alloy (Ag/Ni) | Zamak | Complete product | 3 positions +/- 45° | 7000000 Pa at 55 ℃, distance : 0.1 m | Standard contacts | 0.14 N.m NO changing electrical state | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 | 1 kV conforming to IEC 61000-4-5 | 2 kV conforming to IEC 61000-4-4 | 10 V/m conforming to IEC 61000-4-3 | Class B conforming to IEC 55011 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Part Number |
---|
XB4BK121M5 |
XB4BK124G5 |
XB4BK131M5 |
XB4BK133B5 |
XB4BK133M5 |
XB4BK134M5 |
XB4BK135B5 |
XB4BK135M5 |
XB4BK136B5 |
XB4BK136M5 |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | Number of Positions |
---|---|---|---|---|---|---|
฿ 1,221.00 ฿ 861.90 | SELECTOR SWITCH | 1 Piece(s) | 2 Day(s) | 2 positions 90° | ||
฿ 1,221.00 ฿ 861.90 | SELECTOR SWITCH R | 1 Piece(s) | 2 Day(s) | 2 positions 90° | ||
฿ 1,221.00 ฿ 861.90 | 240V SELECTOR SWITCH WH | 1 Piece(s) | 2 Day(s) | 3 positions +/- 45° | ||
฿ 1,221.00 ฿ 861.90 | 24V SELECTOR SWITCH G | 1 Piece(s) | 2 Day(s) | 3 positions +/- 45° | ||
฿ 1,221.00 ฿ 861.90 | 240V SELECTOR SWITCH G | 1 Piece(s) | 60 Day(s) | 3 positions +/- 45° | ||
฿ 1,221.00 ฿ 861.90 | 240V SELECTOR SWITCH R | 1 Piece(s) | 75 Day(s) | 3 positions +/- 45° | ||
฿ 1,221.00 ฿ 879.97 | 24V SELECTOR SWITCH Y | 1 Piece(s) | Same day | 3 positions +/- 45° | ||
฿ 1,221.00 ฿ 861.90 | 240V SELECTOR SWITCH Y | 1 Piece(s) | 2 Day(s) | 3 positions +/- 45° | ||
฿ 1,221.00 ฿ 861.90 | 240V SELECTOR SWITCH | 1 Piece(s) | 60 Day(s) | 3 positions +/- 45° | ||
฿ 1,221.00 ฿ 861.90 | 240V SELECTOR SWITCH BL | 1 Piece(s) | 2 Day(s) | 3 positions +/- 45° |
Loading...
Mounting Hole | Ø22 | Dimension vertical(mm) | 47 mm | Dimension width(mm) | 30 mm |
---|---|---|---|---|---|
Dimension depth(mm) | 68 mm | Series | Harmony XB4 | Minimum Operating Temperature | -40°C |
Cutout Diameter | 70 °C | Contact Configuration | 1 NO + 1 NC | Body Material | Chromium plated metal |
Type of operator | Stay put | Product or component type | Illuminated selector switch |
How can we improve?