Flush Complete Illuminated Push Button, Spring Return Harmony XB4

Brand :
Schneider Electric

Caution

    Product Description

    Flush Complete illuminated Push buttons Ø22 Spring Return

    Product CodeRange of productProduct or component typeDevice short name[Us] rated supply voltageVibration resistanceShock resistanceElectrical durabilityMechanical durabilityWidthHeightDepthNet weightIP degree of protectionNEMA degree of protectionStandardsAmbient air temperature for operationAmbient air temperature for storageProduct certificationsSustainable offer statusEU RoHS DirectiveMercury freeRoHS exemption informationChina RoHS RegulationEnvironmental DisclosureCircularity ProfileWEEEREACH RegulationREACH free of SVHCWarrantyTightening torqueSignalling typeSale per indivisible quantityBulb base[Ui] rated insulation voltage[Ith] conventional free air thermal currentIK degree of protectionMounting diameterLight sourceContacts type and compositionConnections - terminalsBezel materialTerminals description ISO n°1Short-circuit protection[Uimp] rated impulse withstand voltageContact operationPositive openingProtective treatmentOperator additional informationOperating travelElectrical shock protection classType of operatorShape of signaling unit headOperator profileContacts materialFixing collar materialDevice presentationResistance to high pressure washerContacts usageShape of screw head[Ie] rated operational currentElectrical reliabilityHead typeOperating forceService lifeSupply voltage limitsResistance to electrostatic dischargeCurrent consumptionSurge withstandResistance to fast transientsResistance to electromagnetic fieldsElectromagnetic emissionLight block supply
    XB4BW3365Harmony XB4Illuminated push-buttonXB4<= 250 V5 gn (f= 2 to 500 Hz) 
    conforming to
    IEC 60068-2-6
    30 gn (duration = 18 ms) 
    for half sine wave acceleration
    conforming to IEC 60068-2-27
    50 gn (duration = 11 ms) 
    for half sine wave acceleration
    conforming to IEC 60068-2-27
    1000000 cycles, AC-15, 2 A 
    at 230 V, operating rate <3600 cyc/h, 
    load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, AC-15, 3 A 
    at 120 V, operating rate <3600 cyc/h, 
    load factor: 0.5 conforming to
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, AC-15, 4 A 
    at 24 V, operating rate <3600 cyc/h, 
    load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, DC-13, 0.2 A 
    at 110 V, operating rate <3600 cyc/h, 
    load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, DC-13, 0.5 A 
    at 24 V, operating rate <3600 cyc/h, 
    load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    10000000 cycles30 mm47 mm57 mm0.097 kgIP66 conforming to IEC 60529
    IP67
    IP69
    IP69K
    NEMA 13
    NEMA 4X
    UL 508
    JIS C8201-5-1
    EN/IEC 
    60947-5-1
    EN/IEC 
    60947-5-4
    EN/IEC 
    60947-5-5
    EN/IEC 60947-1
    CSA C22.2 No 14
    JIS C8201-1
    -40 to 55 °C-40 to 70 °CRINA
    CSA
    BV
    GL
    DNV
    UL listed
    LROS (Lloyds register of shipping)
    Green Premium productPro-active compliance 
    (Product out of EU RoHS legal scope)  EU RoHS Declaration
    YesYesChina RoHS declarationProduct Environmental ProfileEnd of Life InformationThe product must be disposed on 
    European Union markets 
    following specific waste collection
    and never end up in rubbish bins
    REACH DeclarationYes18 months0.8 to 1.2 N.m 
    conforming to EN 60947-1
    Steady1BA 9s600 V 
    (pollution degree 3) 
    conforming to 
    EN/IEC 60947-1
    10 A conforming to EN/IEC 60947-5-1IK06 conforming to IEC 5010222 mmBulb not included1 NO + 1 NCScrew clamp terminals, <= 2 x 1.5 mm2  
    with cable end conforming to 
    EN/IEC 60947-1
    Screw clamp terminals, 1 x 0.22...2 x 2.5 mm2  
    without cable end conforming to 
    EN/IEC 60947-1
    Chromium plated metal(13-14)NO
    (21-22)NC
    10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1EN/IEC 60947-1 6 kVSlow-breakWith conforming to EN/IEC 60947-5-1 appendix KTHWith plain lens1.5 mm 
    (NC changing electrical state)
    2.6 mm
    (NO changing electrical state)
    4.3 mm (total travel)
    Class I conforming to IEC 60536Spring returnRoundGreen flushSilver alloy (Ag/Ni)ZamakComplete product7000000 Pa at 55 °C, distance : 0.1 mStandard contactsCross compatible with Philips no 1 screwdriver
    Cross compatible with pozidriv No 1 screwdriver
    Slotted compatible with flat Ø 4 mm screwdriver
    Slotted compatible with flat Ø 5.5 mm screwdriver
    3 A at 240 V, AC-15, A600 
    conforming to 
    EN/IEC 60947-5-1
    6 A at 120 V, AC-15, 
    A600 conforming to 
    EN/IEC 60947-5-1
    0.1 A at 600 V, DC-13, 
    Q600 conforming to 
    EN/IEC 60947-5-1
    0.27 A at 250 V, DC-13, 
    Q600 conforming to 
    EN/IEC 60947-5-1
    0.55 A at 125 V, DC-13, Q600 conforming to 
    EN/IEC 60947-5-1
    1.2 A at 600 V, AC15, 
    A600 conforming to 
    EN/IEC 60947-5-1
    Λ  < 10exp(-6) at 5 V and 1 mA 
    in clean environment conforming to 
    EN/IEC 60947-5-4
    Λ  < 10exp(-8) at 17 V and 5 mA 
    in clean environment conforming to 
    EN/IEC 60947-5-4
    Standard3.5 N NC 
    changing electrical state
    3.8 N
    --------Direct <2.4 W
    XB4BW34M5Harmony XB4Illuminated push-buttonXB4220...240 V AC at 50/60 Hz5 gn (f= 2 to 500 Hz) 
    conforming to 
    IEC 60068-2-6
    30 gn (duration = 18 ms) 
    for half sine wave acceleration 
    conforming to IEC 60068-2-27
    50 gn (duration = 11 ms) 
    for half sine wave acceleration 
    conforming to IEC 60068-2-27
    1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    10000000 cycles30 mm47 mm57 mm0.17 kgIP66 conforming to IEC 60529
    IP67
    IP69
    IP69K
    NEMA 13
    NEMA 4X
    EN/IEC 60947-1
    JIS C8201-5-1
    EN/IEC 
    60947-5-5
    CSA C22.2 No 14
    EN/IEC 
    60947-5-1
    UL 508
    EN/IEC 
    60947-5-4
    JIS C8201-1
    -40 to 70 °C-40 to 70 °CBV
    UL listed
    CSA
    LROS (Lloyds register of shipping)
    DNV
    GL
    RINA
    Green Premium productPro-active compliance 
    (Product out of EU RoHS legal scope)  EU RoHS Declaration
    YesYesChina RoHS declarationProduct Environmental ProfileEnd of Life InformationThe product must be disposed on 
    European Union markets 
    following specific waste collection
    and never end up in rubbish bins
    REACH DeclarationYes18 months0.8 to 1.2 N.m 
    conforming to EN 60947-1
    Steady1Integral LED600 V 
    (pollution degree 3) 
    conforming to 
    EN/IEC 60947-1
    10 A conforming to EN/IEC 60947-5-1IK06 conforming to IEC 5010222 mmProtected LED1 NO + 1 NCScrew clamp terminals, <= 2 x 1.5 mm2  
    with cable end conforming to
    EN/IEC 60947-1
    Screw clamp terminals, 1 x 0.22...2 x 2.5 mm2  
    without cable end conforming to 
    EN/IEC 60947-1
    Chromium plated metal(13-14)NO
    (21-22)NC
    10 A cartridge fuse type gG conforming to EN/IEC 60947-5-16 kV EN/IEC 60947-1Slow-breakWith conforming to EN/IEC 60947-5-1 appendix KTHWith plain lens1.5 mm
    (NC changing electrical state)
    2.6 mm
    (NO changing electrical state)
    4.3 mm (total travel)
    Class I conforming to IEC 60536Spring returnRoundRed flushSilver alloy (Ag/Ni)ZamakComplete product7000000 Pa at 55 °C, distance : 0.1 mStandard contactsCross compatible with Philips no 1 screwdriver
    Cross compatible with pozidriv No 1 screwdriver
    Slotted compatible with flat Ø 4 mm screwdriver
    Slotted compatible with flat Ø 5.5 mm screwdriver
    3 A at 240 V, AC-15, 
    A600 conforming to
    EN/IEC 60947-5-1
    6 A at 120 V, AC-15, 
    A600 conforming to 
    EN/IEC 60947-5-1
    0.1 A at 600 V, DC-13, 
    Q600 conforming to 
    EN/IEC 60947-5-1
    0.27 A at 250 V, DC-13, 
    Q600 conforming to 
    EN/IEC 60947-5-1
    0.55 A at 125 V, DC-13, 
    Q600 conforming to 
    EN/IEC 60947-5-1
    1.2 A at 600 V, AC-15, 
    A600 conforming to 
    EN/IEC 60947-5-1
    Λ  < 10exp(-6) at 5 V and 1 mA 
    in clean environment conforming to
    EN/IEC 60947-5-4
    Λ  < 10exp(-8) at 17 V and 5 mA 
    in clean environment conforming to 
    EN/IEC 60947-5-4
    Standard3.5 N NC 
    changing electrical state
    3.8 N
    100000 h at rated voltage and 25 °C195 to 264 V AC6 kV on contact (on metal parts) conforming to IEC 61000-4-2
    8 kV in free air (in insulating parts) conforming to IEC 61000-4-2
    14 mA1 kV 
    conforming to
    IEC 61000-4-5
    2 kV 
    conforming to IEC 61000-4-4
    10 V/m conforming to IEC 61000-4-3Class B conforming to IEC 55011-
    XB4BW35G5Harmony XB4Illuminated push-buttonXB4110...120 V AC at 50/60 Hz5 gn (f= 2 to 500 Hz) 
    conforming to 
    IEC 60068-2-6
    30 gn (duration = 18 ms)
    for half sine wave acceleration
    conforming to IEC 60068-2-27
    50 gn (duration = 11 ms) 
    for half sine wave acceleration 
    conforming to IEC 60068-2-27
    1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    10000000 cycles30 mm47 mm101 mm0.097 kgIP66 conforming to IEC 60529
    IP67
    IP69
    IP69K
    NEMA 13
    NEMA 4X
    EN/IEC 60947-1
    CSA C22.2 No 14
    JIS C8201-5-1
    EN/IEC 
    60947-5-1
    EN/IEC 
    60947-5-5
    EN/IEC 
    60947-5-4
    UL 508
    JIS C8201-1
    -40 to 70 °C-40 to 70 °CCSA
    BV
    GL
    RINA
    UL listed
    LROS (Lloyds register of shipping)
    DNV
    Green Premium productPro-active compliance 
    (Product out of EU RoHS legal scope)  EU RoHS Declaration
    YesYesChina RoHS declarationProduct Environmental ProfileEnd of Life InformationThe product must be disposed on 
    European Union markets 
    following specific waste collection
    and never end up in rubbish binss
    REACH DeclarationYes18 months0.8 to 1.2 N.m conforming to EN 60947-1Steady1Integral LED600 V 
    (pollution degree 3) 
    conforming to
    EN/IEC 60947-1
    10 A conforming to EN/IEC 60947-5-1IK06 conforming to IEC 5010222 mmProtected LED1 NO + 1 NCScrew clamp terminals, <= 2 x 1.5 mm2  
    with cable end conforming to 
    EN/IEC 60947-1
    Screw clamp terminals, 1 x 0.22...2 x 2.5 mm2  
    without cable end conforming to
    EN/IEC 60947-1
    Chromium plated metal(13-14)NO
    (21-22)NC
    10 A cartridge fuse type gG conforming to EN/IEC 60947-5-16 kV EN/IEC 60947-1Slow-breakWith conforming to EN/IEC 60947-5-1 appendix KTHWith plain lens1.5 mm
    (NC changing electrical state)
    2.6 mm 
    (NO changing electrical state)
    4.3 mm (total travel)
    Class I conforming to IEC 60536Spring returnRoundOrange flushSilver alloy (Ag/Ni)ZamakComplete product7000000 Pa at 55 °C, distance : 0.1 mStandard contactsCross compatible with Philips no 1 screwdriver
    Cross compatible with pozidriv No 1 screwdriver
    Slotted compatible with flat Ø 4 mm screwdriver
    Slotted compatible with flat Ø 5.5 mm screwdriver
    3 A at 240 V, AC-15,
    A600 conforming to
    EN/IEC 60947-5-1
    6 A at 120 V, AC-15,
    A600 conforming to 
    EN/IEC 60947-5-1
    0.1 A at 600 V, DC-13, 
    Q600 conforming to 
    EN/IEC 60947-5-1
    0.27 A at 250 V, DC-13, Q600 conforming to
    EN/IEC 60947-5-1
    0.55 A at 125 V, DC-13, Q600 conforming to 
    EN/IEC 60947-5-1
    1.2 A at 600 V, AC-15, 
    A600 conforming to 
    EN/IEC 60947-5-1
    Λ  < 10exp(-6) at 5 V and 1 mA 
    in clean environment conforming to 
    EN/IEC 60947-5-4
    Λ  < 10exp(-8) at 17 V and 5 mA 
    in clean environment conforming to
    EN/IEC 60947-5-4
    Standard3.5 N NC 
    changing electrical state
    3.8 N
    100000 h at rated voltage and 25 °C100 to 132 V AC6 kV on contact (on metal parts) conforming to IEC 61000-4-2
    8 kV in free air (in insulating parts) conforming to IEC 61000-4-2
    14 mA1 kV 
    conforming to
    IEC 61000-4-5
    2 kV 
    conforming to IEC 61000-4-4
    10 V/m conforming to IEC 61000-4-3Class B conforming to IEC 55011-
    XB4BW35M5Harmony XB4Illuminated push-buttonXB4220...240 V AC at 50/60 Hz5 gn (f= 2 to 500 Hz) 
    conforming to
    IEC 60068-2-6
    30 gn (duration = 18 ms)
    for half sine wave acceleration 
    conforming to IEC 60068-2-27
    50 gn (duration = 11 ms)
    for half sine wave acceleration 
    conforming to IEC 60068-2-27
    1000000 cycles, AC-15, 2 A at 
    230 V, operating rate <3600 cyc/h, 
    load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, AC-15, 3 A at 
    120 V, operating rate <3600 cyc/h, 
    load factor: 0.5 conforming to
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, AC-15, 4 A at 
    24 V, operating rate <3600 cyc/h, 
    load factor: 0.5 conforming to
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, DC-13, 0.2 A at 
    110 V, operating rate <3600 cyc/h, 
    load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, DC-13, 0.5 A at 
    24 V, operating rate <3600 cyc/h, 
    load factor: 0.5 conforming to
    EN/IEC 60947-5-1 appendix C
    10000000 cycles30 mm47 mm101 mm0.097 kgIP66 conforming to IEC 60529
    IP67
    IP69
    IP69K
    NEMA 13
    NEMA 4X
    JIS C8201-5-1
    UL 508
    EN/IEC 
    60947-5-5
    EN/IEC 60947-1
    CSA C22.2 No 14
    EN/IEC 
    60947-5-1
    EN/IEC 
    60947-5-4
    JIS C8201-1
    -40 to 70 °C-40 to 70 °CDNV
    CSA
    LROS (Lloyds register of shipping)
    GL
    BV
    UL listed
    RINA
    Green Premium productPro-active compliance 
    (Product out of EU RoHS legal scope)  EU RoHS Declaration
    YesYesChina RoHS declarationProduct Environmental ProfileEnd of Life InformationThe product must be disposed on 
    European Union markets 
    following specific waste collection
    and never end up in rubbish bins
    REACH DeclarationYes18 months0.8 to 1.2 N.m 
    conforming to EN 60947-1
    Steady1Integral LED600 V 
    (pollution degree 3) 
    conforming to 
    EN/IEC 60947-1
    10 A conforming to EN/IEC 60947-5-1IK06 conforming to IEC 5010222 mmProtected LED1 NO + 1 NCScrew clamp terminals, <= 2 x 1.5 mm2 
    with cable end conforming to 
    EN/IEC 60947-1
    Screw clamp terminals, 1 x 0.22...2 x 2.5 mm2
    without cable end conforming to 
    EN/IEC 60947-1
    Chromium plated metal(21-22)NC
    (13-14)NO
    10 A cartridge fuse type gG conforming to EN/IEC 60947-5-16 kV EN/IEC 60947-1Slow-breakWith conforming to EN/IEC 60947-5-1 appendix KTHWith plain lens1.5 mm 
    (NC changing electrical state)
    2.6 mm 
    (NO changing electrical state)
    4.3 mm (total travel)
    Class I conforming to IEC 60536Spring returnRoundOrange flushSilver alloy (Ag/Ni)ZamakComplete product7000000 Pa at 55 °C, distance : 0.1 mStandard contactsCross compatible with Philips no 1 screwdriver
    Cross compatible with pozidriv No 1 screwdriver
    Slotted compatible with flat Ø 4 mm screwdriver
    Slotted compatible with flat Ø 5.5 mm screwdriver
    3 A at 240 V, AC-15, 
    A600 conforming to 
    EN/IEC 60947-5-1
    6 A at 120 V, AC-15, 
    A600 conforming to 
    EN/IEC 60947-5-1
    0.1 A at 600 V, DC-13, 
    Q600 conforming to 
    EN/IEC 60947-5-1
    0.27 A at 250 V, DC-13, Q600 conforming to 
    EN/IEC 60947-5-1
    0.55 A at 125 V, DC-13, Q600 conforming to 
    EN/IEC 60947-5-1
    1.2 A at 600 V, AC-15, 
    A600 conforming to
    EN/IEC 60947-5-1
    Λ  < 10exp(-6) at 5 V and 1 mA 
    in clean environment conforming to 
    EN/IEC 60947-5-4
    Λ  < 10exp(-8) at 17 V and 5 mA 
    in clean environment conforming to 
    EN/IEC 60947-5-4
    Standard3.5 N NC 
    changing electrical state
    3.8 N
    100000 h at rated voltage and 25 °C195 to 264 V AC6 kV on contact (on metal parts) conforming to IEC 61000-4-2
    8 kV in free air (in insulating parts) conforming to IEC 61000-4-2
    14 mA1 kV 
    conforming to
    IEC 61000-4-5
    2 kV
    conforming to IEC 61000-4-4
    10 V/m conforming to IEC 61000-4-3Class B conforming to IEC 55011-
    XB4BW36G5Harmony XB4Illuminated push-buttonXB4110...120 V AC at 50/60 Hz5 gn (f= 2 to 500 Hz) 
    conforming to 
    IEC 60068-2-6
    30 gn (duration = 18 ms) 
    for half sine wave acceleration 
    conforming to IEC 60068-2-27
    50 gn (duration = 11 ms)
     for half sine wave acceleration 
    conforming to IEC 60068-2-27
    1000000 cycles, AC-15, 2 A at 
    230 V, operating rate <3600 cyc/h, 
    load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, AC-15, 3 A
    at 120 V, operating rate <3600cyc/h, 
    load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, AC-15, 4 A
    at 24 V, operating rate <3600 cyc/h, 
    load factor: 0.5 conforming to
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, DC-13, 0.2 A 
    at 110 V, operating rate <3600cyc/h, 
    load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    1000000 cycles, DC-13, 0.5 A 
    at 24 V, operating rate <3600 cyc/h, 
    load factor: 0.5 conforming to 
    EN/IEC 60947-5-1 appendix C
    10000000 cycles30 mm47 mm101 mm0.097 kgIP66 conforming to IEC 60529
    IP67
    IP69
    IP69K
    NEMA 13
    NEMA 4X
    JIS C8201-5-1
    EN/IEC 60947-1
    EN/IEC 
    60947-5-4
    EN/IEC 
    60947-5-5
    CSA C22.2 No 14
    UL 508
    EN/IEC 
    60947-5-1
    JIS C8201-1
    -40 to 70 °C-40 to 70 °CLROS (Lloyds register of shipping)
    RINA
    BV
    UL listed
    CSA
    DNV
    GL
    Green Premium productPro-active compliance 
    (Product out of EU RoHS legal scope)  EU RoHS Declaration
    YesYesChina RoHS declarationProduct Environmental ProfileEnd of Life InformationThe product must be disposed on 
    European Union markets 
    following specific waste collection
    and never end up in rubbish bins
    REACH DeclarationYes18 months0.8 to 1.2 N.m 
    conforming to EN 60947-1
    Steady1Integral LED600 V 
    (pollution degree 3) 
    conforming to
    EN/IEC 60947-1
    10 A conforming to EN/IEC 60947-5-1IK06 conforming to IEC 5010222 mmProtected LED1 NO + 1 NCScrew clamp terminals, <= 2 x 1.5 mm2 
    with cable end conforming to 
    EN/IEC 60947-1
    Screw clamp terminals, 1 x 0.22...2 x 2.5 mm2 
    without cable end conforming to 
    EN/IEC 60947-1
    Chromium plated metal(21-22)NC
    (13-14)NO
    10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1EN/IEC 60947-1 6 kVSlow-breakWith conforming to EN/IEC 60947-5-1 appendix KTHWith plain lens1.5 mm
    (NC changing electrical state)
    2.6 mm 
    (NO changing electrical state)
    4.3 mm (total travel)
    Class I conforming to IEC 60536Spring returnRoundBlue flushSilver alloy (Ag/Ni)ZamakComplete product7000000 Pa at 55 °C, distance : 0.1 mStandard contactsCross compatible with Philips no 1 screwdriver
    Cross compatible with pozidriv No 1 screwdriver
    Slotted compatible with flat Ø 4 mm screwdriver
    Slotted compatible with flat Ø 5.5 mm screwdriver
    3 A at 240 V, AC-15, 
    A600 conforming to 
    EN/IEC 60947-5-1
    6 A at 120 V, AC-15, 
    A600 conforming to 
    EN/IEC 60947-5-1
    0.1 A at 600 V, DC-13,
    Q600 conforming to 
    EN/IEC 60947-5-1
    0.27 A at 250 V, DC-13, Q600 conforming to 
    EN/IEC 60947-5-1
    0.55 A at 125 V, 
    DC-13, Q600 conforming to 
    EN/IEC 60947-5-1
    1.2 A at 600 V, AC-15, A600 
    conforming to 
    EN/IEC 60947-5-1
    Λ  < 10exp(-6) at 5 V and 1 mA 
    in clean environment conforming to 
    EN/IEC 60947-5-4
    Λ  < 10exp(-8) at 17 V and 5 mA 
    in clean environment conforming to 
    EN/IEC 60947-5-4
    Standard3.5 N NC 
    changing electrical state
    3.8 N
    100000 h at rated voltage and 25 °C100 to 132 V AC6 kV on contact (on metal parts) conforming to IEC 61000-4-2
    8 kV in free air (in insulating parts) conforming to IEC 61000-4-2
    14 mA1 kV 
    conforming to
    IEC 61000-4-5
    2 kV 
    conforming to IEC 61000-4-4
    10 V/m conforming to IEC 61000-4-3Class B conforming to IEC 55011-
    Viewed Products
    Recently Viewed Products
    My Components
    My Components
    0
    Cart
    Cart
    Economy Series
    MRO Product

    Chat with MISUMI

    Chat service is available for any inquiry to MISUMI

    Service hours

    9:00 - 18:00 (Mon-Sat)

    For out of service hours, you can leave a message to us.
    We will reply to your inquiries on the next business day.
    (except Sundays and public holidays).

    Noted for use

    Chat service is for Corporate customers and limited for Thai language.

    Request for Quotation and Place Order is not available on Chat.

    Start chat