TeSys K reversing Contactor

Brand :
Schneider Electric
Caution
Product Description
TeSys K reversing Contactor 3P
| Product Code | Product or component type | Device short name | Electrical durability | Mechanical durability | Width | Height | Depth | Net weight | IP degree of protection | Standards | Ambient air temperature for operation | Ambient air temperature for storage | Product certifications | Sustainable offer status | EU RoHS Directive | Mercury free | RoHS exemption information | China RoHS Regulation | Environmental Disclosure | Circularity Profile | WEEE | Operating altitude | REACH Regulation | REACH free of SVHC | Warranty | Motor power kW | Utilisation category | [Uc] control circuit voltage | Tightening torque | Minimum switching current | Range | Auxiliary contact composition | [Ue] rated operational voltage | [Ui] rated insulation voltage | [Ith] conventional free air thermal current | Minimum switching voltage | Overvoltage category | Connections - terminals | Poles description | Maximum operating rate | [Uimp] rated impulse withstand voltage | Protective treatment | Product name | Flame retardance | Insulation resistance | Device application | Device presentation | [Ie] rated operational current | Mounting support | Irms rated making capacity | [Icw] rated short-time withstand current | Contactor application | Power pole contact composition | Control circuit type | Rated breaking capacity | Associated fuse rating | Average impedance | Control circuit voltage limits | Operating time | Inrush power in VA | Hold-in power consumption in VA | Heat dissipation | Mechanical robustness | Auxiliary contacts type | Safety reliability level | Interlocking type | Signalling circuit frequency | Non overlap distance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LC2K1210E7 | Reversing contactor | LC2K | 0.3 Mcycles 20 A AC-1 at Ue <= 440 V 1.3 Mcycles 12 A AC-3 at Ue <= 440 V | 5 Mcycles | 90 mm | 58 mm | 57 mm | 0.39 kg | IP20 conforming to VDE 0106 | BS 5424 VDE 0660 IEC 60947 NF C 63-110 | -25 to 50 ℃ | -50 to 80 ℃ | UL CSA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | End of Life Information | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 2000 m without derating | REACH Declaration | Yes | 18 months | 4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 3 kW at 220...230 V AC 50/60 Hz 5.5 kW at 380...415 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz | AC-1 AC-4 AC-3 | 48 V AC 50/60 Hz | 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm | 5 mA for signalling circuit | TeSys | 1 NO | Power circuit: 690 V AC 50/60 Hz Signalling circuit: <= 690 V AC 50/60 Hz | Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-5-1 Signalling circuit: 600 V conforming to UL 508 Power circuit: 600 V conforming to CSA C22.2 No 14 Signalling circuit: 600 V conforming to CSA C22.2 No 14 | 20 A (at 50 ℃) for power circuit 10 A (at 50 ℃) for signalling circuit | 17 V for signalling circuit | III | Screw clamp terminals 1 cable(s) 1.5 to 4 mm2 solid Screw clamp terminals 1 cable(s) 0.75 to 4 mm2 flexible without cable end Screw clamp terminals 1 cable(s) 0.34 to 2.5 mm2 flexible with cable end Screw clamp terminals 2 cable(s) 1.5 to 4 mm2 solid Screw clamp terminals 2 cable(s) 0.75 to 4 mm2 flexible without cable end Screw clamp terminals 2 cable(s) 0.34 to 1.5 mm2 flexible with cable end | 3P | 3600 cyc/h | 8 kV | TC conforming to IEC 60068 TC conforming to DIN 50016 | TeSys K | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 | > 10 MOhm for signalling circuit | Control | Preassembled with reversing power busbar | 20 A (at <50 ℃) at <= 440 V AC AC-1 for power circuit 16 A (at <70 ℃) at 690 V AC AC-1 for power circuit 12 A at <= 440 V AC AC-3 for power circuit | Plate Rail | 144 A at 690 V AC for power circuit conforming to NF C 63-110 144 A at 690 V AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947 | 115 A 50 ℃ - 1 s for power circuit 105 A 50 ℃ - 5 s for power circuit 100 A 50 ℃ - 10 s for power circuit 75 A 50 ℃ - 30 s for power circuit 55 A 50 ℃ - 1 min for power circuit 50 A 50 ℃ - 3 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit 25 A 50 ℃ - >= 15 min for power circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 | 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660 | 3 mOhm - Ith 20 A 50 Hz for power circuit | Operational: 0.8...1.15 Uc (at <50 ℃) Drop-out: 0.2...0.75 Uc (at <50 ℃) | 10...20 ms coil energisation and NO closing 10...20 ms coil de-energisation and NO opening | 30 VA (at 20 ℃) | 4.5 VA (at 20 ℃) | 1.3 W | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 | Type instantaneous 1 NO | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | Mechanical | <= 400 Hz | 0.5 mm |
| LC2K1601B7 | Reversing contactor | LC2K | 1.3 Mcycles 16 A AC-3 at Ue <= 440 V | 5 Mcycles | 90 mm | 58 mm | 57 mm | 0.39 kg | IP20 conforming to VDE 0106 | EN/IEC 60947-4-1 EN/IEC 60947-5-1 | -25 to 50 ℃ | -50 to 80 ℃ | CB Scheme | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | End of Life Information | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 2000 m without derating | REACH Declaration | Yes | 18 months | 4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz 4 kW at 220...230 V AC 50/60 Hz 7.5 kW at 380...415 V AC 50/60 Hz | AC-3 AC-4 | 24 V AC 50/60 Hz | 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm | 5 mA for signalling circuit | TeSys | 1 NC | Power circuit: 690 V AC 50/60 Hz Signalling circuit: <= 690 V AC 50/60 Hz | Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-5-1 Signalling circuit: 600 V conforming to UL 508 Power circuit: 600 V conforming to CSA C22.2 No 14 Signalling circuit: 600 V conforming to CSA C22.2 No 14 | 20 A (at 50 ℃) for power circuit 10 A (at 50 ℃) for signalling circuit | 17 V for signalling circuit | III | Screw clamp terminals 1 cable(s) 1.5 to 4 mm2 solid Screw clamp terminals 1 cable(s) 0.75 to 4 mm2 flexible without cable end Screw clamp terminals 1 cable(s) 0.34 to 2.5 mm2 flexible with cable end Screw clamp terminals 2 cable(s) 1.5 to 4 mm2 solid Screw clamp terminals 2 cable(s) 0.75 to 4 mm2 flexible without cable end Screw clamp terminals 2 cable(s) 0.34 to 1.5 mm2 flexible with cable end | 3P | 3600 cyc/h | 8 kV | TC conforming to IEC 60068 TC conforming to DIN 50016 | TeSys K | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 | > 10 MOhm for signalling circuit | Control | Preassembled with reversing power busbar | 16 A at <= 440 V AC AC-3 for power circuit | Plate Rail | 160 A at 690 V AC for power circuit conforming to NF C 63-110 160 A at 690 V AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947 | 115 A 50 ℃ - 1 s for power circuit 105 A 50 ℃ - 5 s for power circuit 100 A 50 ℃ - 10 s for power circuit 75 A 50 ℃ - 30 s for power circuit 55 A 50 ℃ - 1 min for power circuit 50 A 50 ℃ - 3 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit 25 A 50 ℃ - >= 15 min for power circuit | Motor control | 3 NO | AC at 50/60 Hz | 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 | 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660 | 3 mOhm - Ith 20 A 50 Hz for power circuit | Drop-out: 0.2...0.75 Uc (at <50 ℃) Operational: 0.85...1.15 Uc (at <50 ℃) | 10...20 ms coil energisation and NO closing 10...20 ms coil de-energisation and NO opening | 30 VA (at 20 ℃) | 4.5 VA (at 20 ℃) | 1.3 W | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 | Type instantaneous 1 NC | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | Mechanical | <= 400 Hz | 0.5 mm |