TeSys D Contactor
Brand :
Schneider Electric
Caution
Product Description
TeSys D contactors and reversing contactors are available from 9 A to 150 A (inductive motor), and from 20 A to 200 A (resistive loads) in 3-pole and 4-pole versions.

| Product Code | Product or component type | Device short name | Electrical durability | Mechanical durability | Width | Height | Depth | Net weight | IP degree of protection | Pollution degree | Standards | Ambient air temperature for storage | Product certifications | Sustainable offer status | EU RoHS Directive | Mercury free | RoHS exemption information | China RoHS Regulation | Environmental Disclosure | WEEE | Operating altitude | REACH Regulation | Warranty | Utilisation category | [Uc] control circuit voltage | Tightening torque | Range | [Ue] rated operational voltage | [Ui] rated insulation voltage | [Ith] conventional free air thermal current | Overvoltage category | Connections - terminals | Poles description | Maximum operating rate | [Uimp] rated impulse withstand voltage | Protective treatment | Product name | Flame retardance | [Ie] rated operational current | Mounting support | Irms rated making capacity | [Icw] rated short-time withstand current | Contactor application | Power pole contact composition | Control circuit type | Rated breaking capacity | Associated fuse rating | Average impedance | Power dissipation per pole | Operating time | Fire resistance | Mechanical robustness | Safety reliability level | Front cover | Coil technology | Compatibility code | Contact compatibility | Minimum switching current | Auxiliary contact composition | Minimum switching voltage | Insulation resistance | Non-overlap time | Auxiliary contacts type | Signalling circuit frequency | Inrush power in VA | Hold-in power consumption in VA | Heat dissipation | REACH free of SVHC | Toxic heavy metal free | Circularity Profile | Motor power kW | Motor power HP (UL / CSA) | Motor starter type | Motor power range | Contactor coil voltage | Hold-in power consumption in W | Time constant | Inrush power in W | Ambient air temperature for operation | Control circuit voltage limits | Permissible ambient air temperature around the device |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LC1D096M7 | Contactor | LC1D | 0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 at Ue <= 440 V | 15 Mcycles | 45 mm | 77 mm | 86 mm | 0.32 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | DNV UL CSA BV CCC RINA GL LROS (Lloyds register of shipping) GOST | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 220 V AC 50/60 Hz | Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat O 6 mm M3.5 Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5 Power circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat O 8 mm M3.5 Power circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 25 A (at 60 ℃) for power circuit 10 A (at 60 ℃) for signalling circuit | III | Control circuit: lugs-ring terminals (external diameter: 8 mm) Power circuit: lugs-ring terminals (external diameter: 8 mm) | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 9 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 25 A gG at <= 690 V coordination type 1 for power circuit 20 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 1.56 W AC-1 0.2 W AC-3 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | - | - | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 2.2 kW at 220...230 V AC 50/60 Hz (AC-3) 4 kW at 380...400 V AC 50/60 Hz (AC-3) 4 kW at 415...440 V AC 50/60 Hz (AC-3) 5.5 kW at 500 V AC 50/60 Hz (AC-3) 5.5 kW at 660...690 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) | 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors | - | - | - | - | - | - | -5 to 60 ℃ | Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 ℃) Operational: 0.8...1.1 Uc AC 50 Hz (at 60 ℃) Operational: 0.85...1.1 Uc AC 60 Hz (at 60 ℃) | -40 to 70 ℃ at Uc |
| LC1D09D7 | Contactor | LC1D | 0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 at Ue <= 440 V | 15 Mcycles | 45 mm | 77 mm | 86 mm | 0.32 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | BV LROS (Lloyds register of shipping) CSA UL DNV CCC GOST RINA GL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 42 V AC 50/60 Hz | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 25 A (at 60 ℃) for power circuit 10 A (at 60 ℃) for signalling circuit | III | Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 9 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 25 A gG at <= 690 V coordination type 1 for power circuit 20 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 1.56 W AC-1 0.2 W AC-3 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 2.2 kW at 220...230 V AC 50/60 Hz (AC-3) 4 kW at 380...400 V AC 50/60 Hz (AC-3) 4 kW at 415...440 V AC 50/60 Hz (AC-3) 5.5 kW at 500 V AC 50/60 Hz (AC-3) 5.5 kW at 660...690 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) | 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors | Direct on-line contactor | 0 to 0.5 kW at 100 to 120 V 3 phases 0.55 to 1 kW at 100 to 120 V 3 phases 0 to 0.5 kW at 200 to 240 V 3 phases 0.55 to 1 kW at 200 to 240 V 3 phases 1.1 to 2 kW at 200 to 240 V 3 phases 0 to 0.5 kW at 380 to 440 V 3 phases 0.55 to 1 kW at 380 to 440 V 3 phases 1.1 to 2 kW at 380 to 440 V 3 phases 2.2 to 3 kW at 380 to 440 V 3 phases 4 to 6 kW at 380 to 440 V 3 phases 0 to 0.5 kW at 480 to 500 V 3 phases 0.55 to 1 kW at 480 to 500 V 3 phases 1.1 to 2 kW at 480 to 500 V 3 phases 2.2 to 3 kW at 480 to 500 V 3 phases 4 to 6 kW at 480 to 500 V 3 phases 0 to 0.5 kW at 525 to 690 V 3 phases 0.55 to 1 kW at 525 to 690 V 3 phases 1.1 to 2 kW at 525 to 690 V 3 phases 2.2 to 3 kW at 525 to 690 V 3 phases 4 to 6 kW at 525 to 690 V 3 phases | - | - | - | - | - | - | - |
| LC1D09FD | Contactor | LC1D | 0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 at Ue <= 440 V | 30 Mcycles | 45 mm | 77 mm | 95 mm | 0.48 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | UL GL DNV CCC CSA LROS (Lloyds register of shipping) RINA GOST BV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-3 AC-1 | 110 V DC | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 25 A (at 60 ℃) for power circuit 10 A (at 60 ℃) for signalling circuit | III | Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 9 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | DC standard | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 25 A gG at <= 690 V coordination type 1 for power circuit 20 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 1.56 W AC-1 0.2 W AC-3 | 53.55...72.45 ms closing 16...24 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Built-in bidirectional peak limiting diode suppressor | LC1D | M4 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | - | - | - | - | - | End of Life Information | 2.2 kW at 220...230 V AC 50/60 Hz (AC-3) 4 kW at 380...400 V AC 50/60 Hz (AC-3) 4 kW at 415...440 V AC 50/60 Hz (AC-3) 5.5 kW at 500 V AC 50/60 Hz (AC-3) 5.5 kW at 660...690 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) | 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors | - | - | - | 5.4 W at 20 ℃ | 28 ms | 5.4 W (at 20 ℃) | - | - | - |
| LC1D09Q7 | Contactor | LC1D | 0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 at Ue <= 440 V | 15 Mcycles | 45 mm | 77 mm | 86 mm | 0.32 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | UL CSA DNV GL RINA CCC BV GOST LROS (Lloyds register of shipping) | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 380 V AC 50/60 Hz | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 25 A (at 60 ℃) for power circuit 10 A (at 60 ℃) for signalling circuit | III | Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 9 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 25 A gG at <= 690 V coordination type 1 for power circuit 20 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 1.56 W AC-1 0.2 W AC-3 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 2.2 kW at 220...230 V AC 50/60 Hz (AC-3) 4 kW at 380...400 V AC 50/60 Hz (AC-3) 4 kW at 415...440 V AC 50/60 Hz (AC-3) 5.5 kW at 500 V AC 50/60 Hz (AC-3) 5.5 kW at 660...690 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) | 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors | Direct on-line contactor | 0 to 0.5 kW at 100 to 120 V 3 phases 0.55 to 1 kW at 100 to 120 V 3 phases 0 to 0.5 kW at 200 to 240 V 3 phases 0.55 to 1 kW at 200 to 240 V 3 phases 1.1 to 2 kW at 200 to 240 V 3 phases 0 to 0.5 kW at 380 to 440 V 3 phases 0.55 to 1 kW at 380 to 440 V 3 phases 1.1 to 2 kW at 380 to 440 V 3 phases 2.2 to 3 kW at 380 to 440 V 3 phases 4 to 6 kW at 380 to 440 V 3 phases 0 to 0.5 kW at 480 to 500 V 3 phases 0.55 to 1 kW at 480 to 500 V 3 phases 1.1 to 2 kW at 480 to 500 V 3 phases 2.2 to 3 kW at 480 to 500 V 3 phases 4 to 6 kW at 480 to 500 V 3 phases 0 to 0.5 kW at 525 to 690 V 3 phases 0.55 to 1 kW at 525 to 690 V 3 phases 1.1 to 2 kW at 525 to 690 V 3 phases 2.2 to 3 kW at 525 to 690 V 3 phases 4 to 6 kW at 525 to 690 V 3 phases | - | - | - | - | - | - | - |
| LC1D115004M7 | Contactor | LC1D | 0.8 Mcycles 200 A AC-1 at Ue <= 440 V | 8 Mcycles | 150 mm | 158 mm | 132 mm | 2.86 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CCC RINA GOST UL CSA LROS (Lloyds register of shipping) BV GL DNV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 220 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 12 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: <= 1000 V AC 25...400 Hz Power circuit: <= 460 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 | 200 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2solid without cable end Power circuit: connector 1 cable(s) 10 to 120 mm2flexible without cable end Power circuit: connector 2 cable(s) 10 to 50 mm2flexible without cable end Power circuit: connector 1 cable(s) 10 to 120 mm2flexible with cable end Power circuit: connector 2 cable(s) 10 to 50 mm2flexible with cable end Power circuit: connector 1 cable(s) 10 to 120 mm2solid without cable end Power circuit: connector 2 cable(s) 10 to 50 mm2solid without cable end | 4P | 2400 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 200 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 1260 A at 440 V for power circuit conforming to IEC 60947 | 250 A 40 ℃ - 10 min for power circuit 550 A 40 ℃ - 1 min for power circuit 950 A 40 ℃ - 10 s for power circuit 1100 A 40 ℃ - 1 s for power circuit | Resistive load | 4 NO | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 250 A gG at <= 690 V coordination type 1 for power circuit 200 A gG at <= 690 V coordination type 2 for power circuit | 0.6 mOhm - Ith 200 A 50 Hz for power circuit | 24 W AC-1 | 6...20 ms opening 20...50 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 6 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Built-in bidirectional peak limiting diode suppressor | LC1D | M14 | - | - | - | - | - | - | - | 280 to 350 VA 60 Hz cos phi 0.8 (at 20 ℃) 280 to 350 VA 50 Hz cos phi 0.8 (at 20 ℃) | 2 to 18 VA 60 Hz cos phi 0.3 (at 20 ℃) 2 to 18 VA 50 Hz cos phi 0.3 (at 20 ℃) | 3 to 8 W at 50/60 Hz | - | - | End of Life Information | - | - | - | - | - | - | - | - | - | - | - |
| LC1D115E7 | Contactor | LC1D | 0.8 Mcycles 200 A AC-1 at Ue <= 440 V 0.95 Mcycles 115 A AC-3 at Ue <= 440 V | 8 Mcycles | 120 mm | 158 mm | 136 mm | 2.5 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | DNV CCC RINA GOST BV GL LROS (Lloyds register of shipping) CSA UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 48 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 12 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: <= 1000 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 200 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2solid without cable end Power circuit: connector 1 cable(s) 10 to 120 mm2flexible without cable end Power circuit: connector 2 cable(s) 10 to 50 mm2flexible without cable end Power circuit: connector 1 cable(s) 10 to 120 mm2flexible with cable end Power circuit: connector 2 cable(s) 10 to 50 mm2flexible with cable end Power circuit: connector 1 cable(s) 10 to 120 mm2solid without cable end Power circuit: connector 2 cable(s) 10 to 50 mm2solid without cable end | 3P | 2400 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 200 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 115 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Plate Rail | 1260 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 250 A 40 ℃ - 10 min for power circuit 550 A 40 ℃ - 1 min for power circuit 950 A 40 ℃ - 10 s for power circuit 1100 A 40 ℃ - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 250 A gG at <= 690 V coordination type 1 for power circuit 200 A gG at <= 690 V coordination type 2 for power circuit 10 A gG for signalling circuit | 0.6 mOhm - Ith 200 A 50 Hz for power circuit | 24 W AC-1 7.9 W AC-3 | 6...20 ms opening 20...50 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 6 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Built-in bidirectional peak limiting diode suppressor | LC1D | M13 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 280 to 350 VA 60 Hz cos phi 0.8 (at 20 ℃) 280 to 350 VA 50 Hz cos phi 0.8 (at 20 ℃) | 2 to 18 VA 60 Hz cos phi 0.3 (at 20 ℃) 2 to 18 VA 50 Hz cos phi 0.3 (at 20 ℃) | 3 to 8 W at 50/60 Hz | - | - | End of Life Information | 30 kW at 220...230 V AC 50/60 Hz (AC-3) 55 kW at 380...400 V AC 50/60 Hz (AC-3) 59 kW at 415...440 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 80 kW at 660...690 V AC 50/60 Hz (AC-3) 65 kW at 1000 V AC 50/60 Hz (AC-3) 18.5 kW at 400 V AC 50/60 Hz (AC-4) | 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 30 to 50 kW at 200 to 240 V 3 phases 55 to 100 kW at 380 to 440 V 3 phases 55 to 100 kW at 480 to 500 V 3 phases | 48 V AC standard | - | - | - | - | - | - |
| LC1D115F7 | Contactor | LC1D | 0.8 Mcycles 200 A AC-1 at Ue <= 440 V 0.95 Mcycles 115 A AC-3 at Ue <= 440 V | 8 Mcycles | 120 mm | 158 mm | 136 mm | 2.5 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | BV UL GL DNV LROS (Lloyds register of shipping) RINA CSA CCC GOST | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 110 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 12 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: <= 1000 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 200 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2solid without cable end Power circuit: connector 1 cable(s) 10 to 120 mm2flexible without cable end Power circuit: connector 2 cable(s) 10 to 50 mm2flexible without cable end Power circuit: connector 1 cable(s) 10 to 120 mm2flexible with cable end Power circuit: connector 2 cable(s) 10 to 50 mm2flexible with cable end Power circuit: connector 1 cable(s) 10 to 120 mm2solid without cable end Power circuit: connector 2 cable(s) 10 to 50 mm2solid without cable end | 3P | 2400 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 200 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 115 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 1260 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 250 A 40 ℃ - 10 min for power circuit 550 A 40 ℃ - 1 min for power circuit 950 A 40 ℃ - 10 s for power circuit 1100 A 40 ℃ - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 250 A gG at <= 690 V coordination type 1 for power circuit 200 A gG at <= 690 V coordination type 2 for power circuit 10 A gG for signalling circuit | 0.6 mOhm - Ith 200 A 50 Hz for power circuit | 24 W AC-1 7.9 W AC-3 | 6...20 ms opening 20...50 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 6 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Built-in bidirectional peak limiting diode suppressor | LC1D | M13 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 280 to 350 VA 60 Hz cos phi 0.8 (at 20 ℃) 280 to 350 VA 50 Hz cos phi 0.8 (at 20 ℃) | 2 to 18 VA 60 Hz cos phi 0.3 (at 20 ℃) 2 to 18 VA 50 Hz cos phi 0.3 (at 20 ℃) | 3 to 8 W at 50/60 Hz | - | - | End of Life Information | 30 kW at 220...230 V AC 50/60 Hz (AC-3) 55 kW at 380...400 V AC 50/60 Hz (AC-3) 59 kW at 415...440 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 80 kW at 660...690 V AC 50/60 Hz (AC-3) 65 kW at 1000 V AC 50/60 Hz (AC-3) 18.5 kW at 400 V AC 50/60 Hz (AC-4) | 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 30 to 50 kW at 200 to 240 V 3 phases 55 to 100 kW at 380 to 440 V 3 phases 55 to 100 kW at 480 to 500 V 3 phases | 110 V AC standard | - | - | - | - | - | - |
| LC1D115K7 | Contactor | LC1D | 0.8 Mcycles 200 A AC-1 at Ue <= 440 V 0.95 Mcycles 115 A AC-3 at Ue <= 440 V | 8 Mcycles | 120 mm | 158 mm | 136 mm | 2.5 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GOST BV CSA RINA CCC UL DNV LROS (Lloyds register of shipping) GL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-1 AC-4 | 100 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 12 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: <= 1000 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 200 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2solid without cable end Power circuit: connector 1 cable(s) 10 to 120 mm2flexible without cable end Power circuit: connector 2 cable(s) 10 to 50 mm2flexible without cable end Power circuit: connector 1 cable(s) 10 to 120 mm2flexible with cable end Power circuit: connector 2 cable(s) 10 to 50 mm2flexible with cable end Power circuit: connector 1 cable(s) 10 to 120 mm2solid without cable end Power circuit: connector 2 cable(s) 10 to 50 mm2solid without cable end | 3P | 2400 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 200 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 115 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 1260 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 250 A 40 ℃ - 10 min for power circuit 550 A 40 ℃ - 1 min for power circuit 950 A 40 ℃ - 10 s for power circuit 1100 A 40 ℃ - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 250 A gG at <= 690 V coordination type 1 for power circuit 200 A gG at <= 690 V coordination type 2 for power circuit 10 A gG for signalling circuit | 0.6 mOhm - Ith 200 A 50 Hz for power circuit | 24 W AC-1 7.9 W AC-3 | 6...20 ms opening 20...50 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 6 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Built-in bidirectional peak limiting diode suppressor | - | - | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 280 to 350 VA 60 Hz cos phi 0.8 (at 20 ℃) 280 to 350 VA 50 Hz cos phi 0.8 (at 20 ℃) | 2 to 18 VA 60 Hz cos phi 0.3 (at 20 ℃) 2 to 18 VA 50 Hz cos phi 0.3 (at 20 ℃) | 3 to 8 W at 50/60 Hz | - | - | End of Life Information | 30 kW at 220...230 V AC 50/60 Hz (AC-3) 55 kW at 380...400 V AC 50/60 Hz (AC-3) 59 kW at 415...440 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 80 kW at 660...690 V AC 50/60 Hz (AC-3) 65 kW at 1000 V AC 50/60 Hz (AC-3) 18.5 kW at 400 V AC 50/60 Hz (AC-4) | 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors | - | - | - | - | - | - | -5 to 60 ℃ | Drop-out: 0.3...0.5 Uc AC 50/60 Hz (at 55 ℃) Operational: 0.8...1.15 Uc AC 50/60 Hz (at 55 ℃) | -40 to 70 ℃ at Uc |
| LC1D115M7 | Contactor | LC1D | 0.8 Mcycles 200 A AC-1 at Ue <= 440 V 0.95 Mcycles 115 A AC-3 at Ue <= 440 V | 8 Mcycles | 120 mm | 158 mm | 136 mm | 2.5 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | RINA CSA CCC BV LROS (Lloyds register of shipping) GL GOST DNV UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-1 AC-3 | 220 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 12 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: <= 1000 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 200 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2solid without cable end Power circuit: connector 1 cable(s) 10 to 120 mm2flexible without cable end Power circuit: connector 2 cable(s) 10 to 50 mm2flexible without cable end Power circuit: connector 1 cable(s) 10 to 120 mm2flexible with cable end Power circuit: connector 2 cable(s) 10 to 50 mm2flexible with cable end Power circuit: connector 1 cable(s) 10 to 120 mm2solid without cable end Power circuit: connector 2 cable(s) 10 to 50 mm2solid without cable end | 3P | 2400 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 200 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 115 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 1260 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 250 A 40 ℃ - 10 min for power circuit 550 A 40 ℃ - 1 min for power circuit 950 A 40 ℃ - 10 s for power circuit 1100 A 40 ℃ - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 250 A gG at <= 690 V coordination type 1 for power circuit 200 A gG at <= 690 V coordination type 2 for power circuit 10 A gG for signalling circuit | 0.6 mOhm - Ith 200 A 50 Hz for power circuit | 24 W AC-1 7.9 W AC-3 | 6...20 ms opening 20...50 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 6 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Built-in bidirectional peak limiting diode suppressor | LC1D | M13 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 280 to 350 VA 60 Hz cos phi 0.8 (at 20 ℃) 280 to 350 VA 50 Hz cos phi 0.8 (at 20 ℃) | 2 to 18 VA 60 Hz cos phi 0.3 (at 20 ℃) 2 to 18 VA 50 Hz cos phi 0.3 (at 20 ℃) | 3 to 8 W at 50/60 Hz | - | - | End of Life Information | 30 kW at 220...230 V AC 50/60 Hz (AC-3) 55 kW at 380...400 V AC 50/60 Hz (AC-3) 59 kW at 415...440 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 80 kW at 660...690 V AC 50/60 Hz (AC-3) 65 kW at 1000 V AC 50/60 Hz (AC-3) 18.5 kW at 400 V AC 50/60 Hz (AC-4) | 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 30 to 50 kW at 200 to 240 V 3 phases 55 to 100 kW at 380 to 440 V 3 phases 55 to 100 kW at 480 to 500 V 3 phases | 220 V AC standard | - | - | - | - | - | - |
| LC1D128B7 | Contactor | LC1D | 0.8 Mcycles 25 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.365 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | DNV RINA GOST CCC GL BV UL CSA LROS (Lloyds register of shipping) | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 24 V AC 50/60 Hz | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 25 A (at 60 ℃) for power circuit 10 A (at 60 ℃) for signalling circuit | III | Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load | 2 NO + 2 NC | AC at 50/60 Hz | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 1.56 W AC-1 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M6 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | - | - | - | - | - | - | - | - | - | - | - |
| LC1D128BD | Contactor | LC1D | 0.8 Mcycles 25 A AC-1 at Ue <= 440 V | 30 Mcycles | 45 mm | 85 mm | 99 mm | 0.525 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | UL CCC GOST DNV BV LROS (Lloyds register of shipping) RINA GL CSA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 24 V DC | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 25 A (at 60 ℃) for power circuit 10 A (at 60 ℃) for signalling circuit | III | Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load | 2 NO + 2 NC | DC standard | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 1.56 W AC-1 | 53.55...72.45 ms closing 16...24 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | With integral suppression device | LC1D | M7 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | - | - | - | - | - | End of Life Information | - | - | - | - | - | 5.4 W at 20 ℃ | 28 ms | 5.4 W (at 20 ℃) | - | - | - |
| LC1D128D7 | Contactor | LC1D | 0.8 Mcycles 25 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.365 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | LROS (Lloyds register of shipping) GOST CSA RINA BV CCC DNV GL UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 42 V AC 50/60 Hz | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 25 A (at 60 ℃) for power circuit 10 A (at 60 ℃) for signalling circuit | III | Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load | 2 NO + 2 NC | AC at 50/60 Hz | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 1.56 W AC-1 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M6 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | - | - | - | - | - | - | - | - | - | - | - |
| LC1D128M7 | Contactor | LC1D | 0.8 Mcycles 25 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.365 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | UL DNV CCC LROS (Lloyds register of shipping) BV CSA RINA GOST GL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 220 V AC 50/60 Hz | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 25 A (at 60 ℃) for power circuit 10 A (at 60 ℃) for signalling circuit | III | Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load | 2 NO + 2 NC | AC at 50/60 Hz | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 1.56 W AC-1 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M6 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | - | - | - | - | - | - | - | - | - | - | - |
| LC1D12B7 | Contactor | LC1D | 2 Mcycles 12 A AC-3 at Ue <= 440 V 0.8 Mcycles 25 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 77 mm | 86 mm | 0.325 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CCC CSA GL GOST BV DNV RINA LROS (Lloyds register of shipping) UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-1 AC-4 | 24 V AC 50/60 Hz | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 25 A (at 60 ℃) for power circuit 10 A (at 60 ℃) for signalling circuit | III | Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 12 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 0.36 W AC-3 1.56 W AC-1 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 3 kW at 220...230 V AC 50/60 Hz (AC-3) 5.5 kW at 380...400 V AC 50/60 Hz (AC-3) 5.5 kW at 415...440 V AC 50/60 Hz (AC-3) 7.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 660...690 V AC 50/60 Hz (AC-3) 3.7 kW at 400 V AC 50/60 Hz (AC-4) | 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors 3 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 380 to 440 V 3 phases 4 to 6 kW at 480 to 500 V 3 phases 2.2 to 3 kW at 200 to 240 V 3 phases | 24 V AC standard | - | - | - | - | - | - |
| LC1D12D7 | Contactor | LC1D | 2 Mcycles 12 A AC-3 at Ue <= 440 V 0.8 Mcycles 25 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 77 mm | 86 mm | 0.325 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CSA RINA GOST BV DNV CCC LROS (Lloyds register of shipping) GL UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 42 V AC 50/60 Hz | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 25 A (at 60 ℃) for power circuit 10 A (at 60 ℃) for signalling circuit | III | Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 12 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Plate Rail | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 0.36 W AC-3 1.56 W AC-1 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 3 kW at 220...230 V AC 50/60 Hz (AC-3) 5.5 kW at 380...400 V AC 50/60 Hz (AC-3) 5.5 kW at 415...440 V AC 50/60 Hz (AC-3) 7.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 660...690 V AC 50/60 Hz (AC-3) 3.7 kW at 400 V AC 50/60 Hz (AC-4) | 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors 3 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 380 to 440 V 3 phases 4 to 6 kW at 480 to 500 V 3 phases 1.1 to 2 kW at 100 to 120 V 3 phases 2.2 to 3 kW at 200 to 240 V 3 phases 7 to 11 kW at 525 to 690 V 3 phases | - | - | - | - | - | - | - |
| LC1D12E7 | Contactor | LC1D | 2 Mcycles 12 A AC-3 at Ue <= 440 V 0.8 Mcycles 25 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 77 mm | 86 mm | 0.325 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | LROS (Lloyds register of shipping) DNV BV RINA GOST GL CSA CCC UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-1 AC-3 | 48 V AC 50/60 Hz | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 25 A (at 60 ℃) for power circuit 10 A (at 60 ℃) for signalling circuit | III | Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 12 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 0.36 W AC-3 1.56 W AC-1 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 3 kW at 220...230 V AC 50/60 Hz (AC-3) 5.5 kW at 380...400 V AC 50/60 Hz (AC-3) 5.5 kW at 415...440 V AC 50/60 Hz (AC-3) 7.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 660...690 V AC 50/60 Hz (AC-3) 3.7 kW at 400 V AC 50/60 Hz (AC-4) | 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors 3 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 380 to 440 V 3 phases 4 to 6 kW at 480 to 500 V 3 phases 2.2 to 3 kW at 200 to 240 V 3 phases | 48 V AC standard | - | - | - | - | - | - |
| LC1D12FD | Contactor | LC1D | 2 Mcycles 12 A AC-3 at Ue <= 440 V 0.8 Mcycles 25 A AC-1 at Ue <= 440 V | 30 Mcycles | 45 mm | 77 mm | 95 mm | 0.485 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CSA BV CCC GOST DNV GL LROS (Lloyds register of shipping) UL RINA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 110 V DC | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 25 A (at 60 ℃) for power circuit 10 A (at 60 ℃) for signalling circuit | III | Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 12 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | DC standard | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 0.36 W AC-3 1.56 W AC-1 | 53.55...72.45 ms closing 16...24 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | With integral suppression device | LC1D | M4 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | - | - | - | - | - | End of Life Information | 3 kW at 220...230 V AC 50/60 Hz (AC-3) 5.5 kW at 380...400 V AC 50/60 Hz (AC-3) 5.5 kW at 415...440 V AC 50/60 Hz (AC-3) 7.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 660...690 V AC 50/60 Hz (AC-3) 3.7 kW at 400 V AC 50/60 Hz (AC-4) | 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors 3 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors | - | - | - | 5.4 W at 20 ℃ | 28 ms | 5.4 W (at 20 ℃) | - | - | - |
| LC1D12M7 | Contactor | LC1D | 2 Mcycles 12 A AC-3 at Ue <= 440 V 0.8 Mcycles 25 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 77 mm | 86 mm | 0.325 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | BV GOST CSA RINA LROS (Lloyds register of shipping) DNV UL GL CCC | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-1 AC-3 | 220 V AC 50/60 Hz | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 25 A (at 60 ℃) for power circuit 10 A (at 60 ℃) for signalling circuit | III | Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 12 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 0.36 W AC-3 1.56 W AC-1 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 3 kW at 220...230 V AC 50/60 Hz (AC-3) 5.5 kW at 380...400 V AC 50/60 Hz (AC-3) 5.5 kW at 415...440 V AC 50/60 Hz (AC-3) 7.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 660...690 V AC 50/60 Hz (AC-3) 3.7 kW at 400 V AC 50/60 Hz (AC-4) | 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors 3 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 380 to 440 V 3 phases 4 to 6 kW at 480 to 500 V 3 phases 2.2 to 3 kW at 200 to 240 V 3 phases | 220 V AC standard | - | - | - | - | - | - |
| LC1D12Q7 | Contactor | LC1D | 2 Mcycles 12 A AC-3 at Ue <= 440 V 0.8 Mcycles 25 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 77 mm | 86 mm | 0.325 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CSA DNV BV GL UL CCC GOST RINA LROS (Lloyds register of shipping) | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 380 V AC 50/60 Hz | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 25 A (at 60 ℃) for power circuit 10 A (at 60 ℃) for signalling circuit | III | Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 12 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 0.36 W AC-3 1.56 W AC-1 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 3 kW at 220...230 V AC 50/60 Hz (AC-3) 5.5 kW at 380...400 V AC 50/60 Hz (AC-3) 5.5 kW at 415...440 V AC 50/60 Hz (AC-3) 7.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 660...690 V AC 50/60 Hz (AC-3) 3.7 kW at 400 V AC 50/60 Hz (AC-4) | 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors 3 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 380 to 440 V 3 phases 4 to 6 kW at 480 to 500 V 3 phases 1.1 to 2 kW at 100 to 120 V 3 phases 2.2 to 3 kW at 200 to 240 V 3 phases 7 to 11 kW at 525 to 690 V 3 phases | - | - | - | - | - | - | - |
| LC1D150M7 | Contactor | LC1D | 0.85 Mcycles 150 A AC-3 at Ue <= 440 V 1 Mcycles 200 A AC-1 at Ue <= 440 V | 8 Mcycles | 120 mm | 158 mm | 136 mm | 2.5 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CCC LROS (Lloyds register of shipping) GL GOST RINA CSA BV UL DNV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 220 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 12 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: <= 1000 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 200 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2solid without cable end Power circuit: connector 1 cable(s) 10 to 120 mm2flexible without cable end Power circuit: connector 2 cable(s) 10 to 50 mm2flexible without cable end Power circuit: connector 1 cable(s) 10 to 120 mm2flexible with cable end Power circuit: connector 2 cable(s) 10 to 50 mm2flexible with cable end Power circuit: connector 1 cable(s) 10 to 120 mm2solid without cable end Power circuit: connector 2 cable(s) 10 to 50 mm2solid without cable end | 3P | 1200 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 200 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 150 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1660 A at 440 V for power circuit conforming to IEC 60947 | 250 A 40 ℃ - 10 min for power circuit 580 A 40 ℃ - 1 min for power circuit 1200 A 40 ℃ - 10 s for power circuit 1400 A 40 ℃ - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 1400 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 315 A gG at <= 690 V coordination type 1 for power circuit 250 A gG at <= 690 V coordination type 2 for power circuit | 0.6 mOhm - Ith 200 A 50 Hz for power circuit | 24 W AC-1 13.5 W AC-3 | 20...35 ms closing 40...75 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 6 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Built-in bidirectional peak limiting diode suppressor | LC1D | M13 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 280 to 350 VA 60 Hz cos phi 0.9 (at 20 ℃) 280 to 350 VA 50 Hz cos phi 0.9 (at 20 ℃) | 2 to 18 VA 60 Hz cos phi 0.9 (at 20 ℃) 2 to 18 VA 50 Hz cos phi 0.9 (at 20 ℃) | 3 to 4.5 W at 50/60 Hz | - | - | End of Life Information | 40 kW at 220...230 V AC 50/60 Hz (AC-3) 75 kW at 380...400 V AC 50/60 Hz (AC-3) 80 kW at 415...440 V AC 50/60 Hz (AC-3) 90 kW at 500 V AC 50/60 Hz (AC-3) 100 kW at 660...690 V AC 50/60 Hz (AC-3) 75 kW at 1000 V AC 50/60 Hz (AC-3) 22 kW at 400 V AC 50/60 Hz (AC-4) | 40 hp at 200/208 V AC 50/60 Hz for 3 phases motors 50 hp at 230/240 V AC 50/60 Hz for 3 phases motors 100 hp at 460/480 V AC 50/60 Hz for 3 phases motors 125 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 30 to 50 kW at 200 to 240 V 3 phases 55 to 100 kW at 380 to 440 V 3 phases 55 to 100 kW at 480 to 500 V 3 phases | 220 V AC standard | - | - | - | - | - | - |
| LC1D18B7 | Contactor | LC1D | 1.65 Mcycles 18 A AC-3 at Ue <= 440 V 1 Mcycles 32 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 77 mm | 86 mm | 0.33 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GOST CCC CSA UL RINA BV LROS (Lloyds register of shipping) DNV GL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 24 V AC 50/60 Hz | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 32 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 6 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 6 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 18 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 32 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 300 A at 440 V for power circuit conforming to IEC 60947 | 145 A 40 ℃ - 10 s for power circuit 240 A 40 ℃ - 1 s for power circuit 40 A 40 ℃ - 10 min for power circuit 84 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 300 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 50 A gG at <= 690 V coordination type 1 for power circuit 35 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 32 A 50 Hz for power circuit | 2.5 W AC-1 0.8 W AC-3 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 4 kW at 220...230 V AC 50/60 Hz (AC-3) 7.5 kW at 380...400 V AC 50/60 Hz (AC-3) 9 kW at 415...440 V AC 50/60 Hz (AC-3) 10 kW at 500 V AC 50/60 Hz (AC-3) 10 kW at 660...690 V AC 50/60 Hz (AC-3) 4 kW at 400 V AC 50/60 Hz (AC-4) | 1 hp at 115 V AC 50/60 Hz for 1 phase motors 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors 5 hp at 200/208 V AC 50/60 Hz for 3 phases motors 5 hp at 230/240 V AC 50/60 Hz for 3 phases motors 10 hp at 460/480 V AC 50/60 Hz for 3 phases motors 15 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 200 to 240 V 3 phases 7 to 11 kW at 380 to 440 V 3 phases 7 to 11 kW at 480 to 500 V 3 phases | 24 V AC standard | - | - | - | - | - | - |
| LC1D18BD | Contactor | LC1D | 1.65 Mcycles 18 A AC-3 at Ue <= 440 V 1 Mcycles 32 A AC-1 at Ue <= 440 V | 30 Mcycles | 45 mm | 77 mm | 95 mm | 0.49 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | LROS (Lloyds register of shipping) DNV GL RINA BV CCC UL CSA GOST | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-1 AC-3 | 24 V DC | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 32 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 6 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 6 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 18 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 32 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 300 A at 440 V for power circuit conforming to IEC 60947 | 145 A 40 ℃ - 10 s for power circuit 240 A 40 ℃ - 1 s for power circuit 40 A 40 ℃ - 10 min for power circuit 84 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | DC standard | 300 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 50 A gG at <= 690 V coordination type 1 for power circuit 35 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 32 A 50 Hz for power circuit | 2.5 W AC-1 0.8 W AC-3 | 53.55...72.45 ms closing 16...24 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | With integral suppression device | LC1D | M4 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | - | - | - | - | - | End of Life Information | 4 kW at 220...230 V AC 50/60 Hz (AC-3) 7.5 kW at 380...400 V AC 50/60 Hz (AC-3) 9 kW at 415...440 V AC 50/60 Hz (AC-3) 10 kW at 500 V AC 50/60 Hz (AC-3) 10 kW at 660...690 V AC 50/60 Hz (AC-3) 4 kW at 400 V AC 50/60 Hz (AC-4) | 1 hp at 115 V AC 50/60 Hz for 1 phase motors 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors 5 hp at 200/208 V AC 50/60 Hz for 3 phases motors 5 hp at 230/240 V AC 50/60 Hz for 3 phases motors 10 hp at 460/480 V AC 50/60 Hz for 3 phases motors 15 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 200 to 240 V 3 phases 7 to 11 kW at 380 to 440 V 3 phases 7 to 11 kW at 480 to 500 V 3 phases | 24 V DC standard | 5.4 W at 20 ℃ | 28 ms | 5.4 W (at 20 ℃) | - | - | - |
| LC1D18D7 | Contactor | LC1D | 1.65 Mcycles 18 A AC-3 at Ue <= 440 V 1 Mcycles 32 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 77 mm | 86 mm | 0.33 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CCC BV CSA GL RINA LROS (Lloyds register of shipping) GOST DNV UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 42 V AC 50/60 Hz | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 32 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 6 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 6 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 18 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 32 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 300 A at 440 V for power circuit conforming to IEC 60947 | 145 A 40 ℃ - 10 s for power circuit 240 A 40 ℃ - 1 s for power circuit 40 A 40 ℃ - 10 min for power circuit 84 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 300 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 50 A gG at <= 690 V coordination type 1 for power circuit 35 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 32 A 50 Hz for power circuit | 2.5 W AC-1 0.8 W AC-3 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 4 kW at 220...230 V AC 50/60 Hz (AC-3) 7.5 kW at 380...400 V AC 50/60 Hz (AC-3) 9 kW at 415...440 V AC 50/60 Hz (AC-3) 10 kW at 500 V AC 50/60 Hz (AC-3) 10 kW at 660...690 V AC 50/60 Hz (AC-3) 4 kW at 400 V AC 50/60 Hz (AC-4) | 1 hp at 115 V AC 50/60 Hz for 1 phase motors 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors 5 hp at 200/208 V AC 50/60 Hz for 3 phases motors 5 hp at 230/240 V AC 50/60 Hz for 3 phases motors 10 hp at 460/480 V AC 50/60 Hz for 3 phases motors 15 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 1.1 to 2 kW at 100 to 120 V 3 phases 7 to 11 kW at 525 to 690 V 3 phases 4 to 6 kW at 200 to 240 V 3 phases 7 to 11 kW at 380 to 440 V 3 phases 7 to 11 kW at 480 to 500 V 3 phases | - | - | - | - | - | - | - |
| LC1D18E7 | Contactor | LC1D | 1.65 Mcycles 18 A AC-3 at Ue <= 440 V 1 Mcycles 32 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 77 mm | 86 mm | 0.33 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GL RINA UL CSA DNV BV GOST LROS (Lloyds register of shipping) CCC | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-1 AC-3 | 48 V AC 50/60 Hz | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 32 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 6 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 6 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 18 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 32 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 300 A at 440 V for power circuit conforming to IEC 60947 | 145 A 40 ℃ - 10 s for power circuit 240 A 40 ℃ - 1 s for power circuit 40 A 40 ℃ - 10 min for power circuit 84 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 300 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 50 A gG at <= 690 V coordination type 1 for power circuit 35 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 32 A 50 Hz for power circuit | 2.5 W AC-1 0.8 W AC-3 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 4 kW at 220...230 V AC 50/60 Hz (AC-3) 7.5 kW at 380...400 V AC 50/60 Hz (AC-3) 9 kW at 415...440 V AC 50/60 Hz (AC-3) 10 kW at 500 V AC 50/60 Hz (AC-3) 10 kW at 660...690 V AC 50/60 Hz (AC-3) 4 kW at 400 V AC 50/60 Hz (AC-4) | 1 hp at 115 V AC 50/60 Hz for 1 phase motors 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors 5 hp at 200/208 V AC 50/60 Hz for 3 phases motors 5 hp at 230/240 V AC 50/60 Hz for 3 phases motors 10 hp at 460/480 V AC 50/60 Hz for 3 phases motors 15 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 200 to 240 V 3 phases 7 to 11 kW at 380 to 440 V 3 phases 7 to 11 kW at 480 to 500 V 3 phases | 48 V AC standard | - | - | - | - | - | - |
| LC1D18F7 | Contactor | LC1D | 1.65 Mcycles 18 A AC-3 at Ue <= 440 V 1 Mcycles 32 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 77 mm | 86 mm | 0.33 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GL RINA UL CCC DNV LROS (Lloyds register of shipping) CSA GOST BV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 110 V AC 50/60 Hz | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 32 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 6 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 6 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 18 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 32 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 300 A at 440 V for power circuit conforming to IEC 60947 | 145 A 40 ℃ - 10 s for power circuit 240 A 40 ℃ - 1 s for power circuit 40 A 40 ℃ - 10 min for power circuit 84 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 300 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 50 A gG at <= 690 V coordination type 1 for power circuit 35 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 32 A 50 Hz for power circuit | 2.5 W AC-1 0.8 W AC-3 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 4 kW at 220...230 V AC 50/60 Hz (AC-3) 7.5 kW at 380...400 V AC 50/60 Hz (AC-3) 9 kW at 415...440 V AC 50/60 Hz (AC-3) 10 kW at 500 V AC 50/60 Hz (AC-3) 10 kW at 660...690 V AC 50/60 Hz (AC-3) 4 kW at 400 V AC 50/60 Hz (AC-4) | 1 hp at 115 V AC 50/60 Hz for 1 phase motors 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors 5 hp at 200/208 V AC 50/60 Hz for 3 phases motors 5 hp at 230/240 V AC 50/60 Hz for 3 phases motors 10 hp at 460/480 V AC 50/60 Hz for 3 phases motors 15 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 200 to 240 V 3 phases 7 to 11 kW at 380 to 440 V 3 phases 7 to 11 kW at 480 to 500 V 3 phases | 110 V AC standard | - | - | - | - | - | - |
| LC1D18M7 | Contactor | LC1D | 1.65 Mcycles 18 A AC-3 at Ue <= 440 V 1 Mcycles 32 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 77 mm | 86 mm | 0.33 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GOST UL RINA CCC DNV BV GL CSA LROS (Lloyds register of shipping) | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 220 V AC 50/60 Hz | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 32 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 6 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 6 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 18 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 32 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 300 A at 440 V for power circuit conforming to IEC 60947 | 145 A 40 ℃ - 10 s for power circuit 240 A 40 ℃ - 1 s for power circuit 40 A 40 ℃ - 10 min for power circuit 84 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 300 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 50 A gG at <= 690 V coordination type 1 for power circuit 35 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 32 A 50 Hz for power circuit | 2.5 W AC-1 0.8 W AC-3 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 4 kW at 220...230 V AC 50/60 Hz (AC-3) 7.5 kW at 380...400 V AC 50/60 Hz (AC-3) 9 kW at 415...440 V AC 50/60 Hz (AC-3) 10 kW at 500 V AC 50/60 Hz (AC-3) 10 kW at 660...690 V AC 50/60 Hz (AC-3) 4 kW at 400 V AC 50/60 Hz (AC-4) | 1 hp at 115 V AC 50/60 Hz for 1 phase motors 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors 5 hp at 200/208 V AC 50/60 Hz for 3 phases motors 5 hp at 230/240 V AC 50/60 Hz for 3 phases motors 10 hp at 460/480 V AC 50/60 Hz for 3 phases motors 15 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 200 to 240 V 3 phases 7 to 11 kW at 380 to 440 V 3 phases 7 to 11 kW at 480 to 500 V 3 phases | 220 V AC standard | - | - | - | - | - | - |
| LC1D18N7 | Contactor | LC1D | 1.65 Mcycles 18 A AC-3 at Ue <= 440 V 1 Mcycles 32 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 77 mm | 86 mm | 0.33 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GOST CSA RINA DNV CCC LROS (Lloyds register of shipping) UL BV GL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 415 V AC 50/60 Hz | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 32 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 6 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 6 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 18 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 32 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 300 A at 440 V for power circuit conforming to IEC 60947 | 145 A 40 ℃ - 10 s for power circuit 240 A 40 ℃ - 1 s for power circuit 40 A 40 ℃ - 10 min for power circuit 84 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 300 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 50 A gG at <= 690 V coordination type 1 for power circuit 35 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 32 A 50 Hz for power circuit | 2.5 W AC-1 0.8 W AC-3 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | - | - | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 4 kW at 220...230 V AC 50/60 Hz (AC-3) 7.5 kW at 380...400 V AC 50/60 Hz (AC-3) 9 kW at 415...440 V AC 50/60 Hz (AC-3) 10 kW at 500 V AC 50/60 Hz (AC-3) 10 kW at 660...690 V AC 50/60 Hz (AC-3) 4 kW at 400 V AC 50/60 Hz (AC-4) | 1 hp at 115 V AC 50/60 Hz for 1 phase motors 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors 5 hp at 200/208 V AC 50/60 Hz for 3 phases motors 5 hp at 230/240 V AC 50/60 Hz for 3 phases motors 10 hp at 460/480 V AC 50/60 Hz for 3 phases motors 15 hp at 575/600 V AC 50/60 Hz for 3 phases motors | - | - | - | - | - | - | -5 to 60 ℃ | Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 ℃) Operational: 0.8...1.1 Uc AC 50 Hz (at 60 ℃) Operational: 0.85...1.1 Uc AC 60 Hz (at 60 ℃) | -40 to 70 ℃ at Uc |
| LC1D258D7 | Contactor | LC1D | 1.4 Mcycles 40 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 105 mm | 99 mm | 0.425 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | RINA GL DNV GOST LROS (Lloyds register of shipping) CCC BV UL CSA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 42 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 1.8 N.m - on connector - with screwdriver flat O 6 mm Power circuit: 1.8 N.m - on connector - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 40 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: connector 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: connector 1 cable(s) 2.5 to 10 mm2flexible with cable end Power circuit: connector 2 cable(s) 2.5 to 10 mm2flexible with cable end Power circuit: connector 1 cable(s) 2.5 to 16 mm2solid without cable end Power circuit: connector 2 cable(s) 2.5 to 16 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 40 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 450 A at 440 V for power circuit conforming to IEC 60947 | 240 A 40 ℃ - 10 s for power circuit 380 A 40 ℃ - 1 s for power circuit 50 A 40 ℃ - 10 min for power circuit 120 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load | 2 NO + 2 NC | AC at 50/60 Hz | 450 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 40 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 40 A 50 Hz for power circuit | 3.2 W AC-1 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M6 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | - | - | - | - | - | - | - | - | - | - | - |
| LC1D258E7 | Contactor | LC1D | 1.4 Mcycles 40 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 105 mm | 99 mm | 0.425 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | DNV RINA GL CCC CSA GOST BV LROS (Lloyds register of shipping) UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 48 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 1.8 N.m - on connector - with screwdriver flat O 6 mm Power circuit: 1.8 N.m - on connector - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 40 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: connector 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: connector 1 cable(s) 2.5 to 10 mm2flexible with cable end Power circuit: connector 2 cable(s) 2.5 to 10 mm2flexible with cable end Power circuit: connector 1 cable(s) 2.5 to 16 mm2solid without cable end Power circuit: connector 2 cable(s) 2.5 to 16 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 40 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 450 A at 440 V for power circuit conforming to IEC 60947 | 240 A 40 ℃ - 10 s for power circuit 380 A 40 ℃ - 1 s for power circuit 50 A 40 ℃ - 10 min for power circuit 120 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load | 2 NO + 2 NC | AC at 50/60 Hz | 450 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 40 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 40 A 50 Hz for power circuit | 3.2 W AC-1 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M6 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | - | - | - | - | - | - | - | - | - | - | - |
| LC1D258M7 | Contactor | LC1D | 1.4 Mcycles 40 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 105 mm | 99 mm | 0.425 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CSA GL BV GOST UL CCC DNV LROS (Lloyds register of shipping) RINA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 220 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 1.8 N.m - on connector - with screwdriver flat O 6 mm Power circuit: 1.8 N.m - on connector - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 40 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: connector 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: connector 1 cable(s) 2.5 to 10 mm2flexible with cable end Power circuit: connector 2 cable(s) 2.5 to 10 mm2flexible with cable end Power circuit: connector 1 cable(s) 2.5 to 16 mm2solid without cable end Power circuit: connector 2 cable(s) 2.5 to 16 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 40 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 450 A at 440 V for power circuit conforming to IEC 60947 | 240 A 40 ℃ - 10 s for power circuit 380 A 40 ℃ - 1 s for power circuit 50 A 40 ℃ - 10 min for power circuit 120 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load | 2 NO + 2 NC | AC at 50/60 Hz | 450 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 40 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 40 A 50 Hz for power circuit | 3.2 W AC-1 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M6 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | - | - | - | - | - | - | - | - | - | - | - |
| LC1D25B7 | Contactor | LC1D | 1.65 Mcycles 25 A AC-3 at Ue <= 440 V 1.4 Mcycles 40 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.37 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GL GOST BV UL LROS (Lloyds register of shipping) DNV CCC CSA RINA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-3 AC-4 | 24 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 40 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 40 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 450 A at 440 V for power circuit conforming to IEC 60947 | 240 A 40 ℃ - 10 s for power circuit 380 A 40 ℃ - 1 s for power circuit 50 A 40 ℃ - 10 min for power circuit 120 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 450 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 40 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 40 A 50 Hz for power circuit | 3.2 W AC-1 1.25 W AC-3 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 5.5 kW at 220...230 V AC 50/60 Hz (AC-3) 11 kW at 380...400 V AC 50/60 Hz (AC-3) 11 kW at 415...440 V AC 50/60 Hz (AC-3) 15 kW at 500 V AC 50/60 Hz (AC-3) 15 kW at 660...690 V AC 50/60 Hz (AC-3) 5.5 kW at 400 V AC 50/60 Hz (AC-4) | 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors 2 hp at 115 V AC 50/60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors 15 hp at 460/480 V AC 50/60 Hz for 3 phases motors 20 hp at 575/600 V AC 50/60 Hz for 3 phases motors 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 200 to 240 V 3 phases 7 to 11 kW at 380 to 440 V 3 phases 7 to 11 kW at 480 to 500 V 3 phases | 24 V AC standard | - | - | - | - | - | - |
| LC1D25BD | Contactor | LC1D | 1.65 Mcycles 25 A AC-3 at Ue <= 440 V 1.4 Mcycles 40 A AC-1 at Ue <= 440 V | 30 Mcycles | 45 mm | 85 mm | 101 mm | 0.53 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | LROS (Lloyds register of shipping) BV GL CCC RINA GOST CSA DNV UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-3 AC-1 | 24 V DC | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 40 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 40 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 450 A at 440 V for power circuit conforming to IEC 60947 | 240 A 40 ℃ - 10 s for power circuit 380 A 40 ℃ - 1 s for power circuit 50 A 40 ℃ - 10 min for power circuit 120 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | DC standard | 450 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 40 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 40 A 50 Hz for power circuit | 3.2 W AC-1 1.25 W AC-3 | 53.55...72.45 ms closing 16...24 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Built-in bidirectional peak limiting diode suppressor | LC1D | M4 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | - | - | - | - | - | End of Life Information | 5.5 kW at 220...230 V AC 50/60 Hz (AC-3) 11 kW at 380...400 V AC 50/60 Hz (AC-3) 11 kW at 415...440 V AC 50/60 Hz (AC-3) 15 kW at 500 V AC 50/60 Hz (AC-3) 15 kW at 660...690 V AC 50/60 Hz (AC-3) 5.5 kW at 400 V AC 50/60 Hz (AC-4) | 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors 2 hp at 115 V AC 50/60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors 15 hp at 460/480 V AC 50/60 Hz for 3 phases motors 20 hp at 575/600 V AC 50/60 Hz for 3 phases motors 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 200 to 240 V 3 phases 7 to 11 kW at 380 to 440 V 3 phases 7 to 11 kW at 480 to 500 V 3 phases | 24 V DC standard | 5.4 W at 20 ℃ | 28 ms | 5.4 W (at 20 ℃) | - | - | - |
| LC1D25D7 | Contactor | LC1D | 1.65 Mcycles 25 A AC-3 at Ue <= 440 V 1.4 Mcycles 40 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.37 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | RINA LROS (Lloyds register of shipping) CCC DNV BV GL CSA GOST UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-1 AC-3 | 42 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 40 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 40 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 450 A at 440 V for power circuit conforming to IEC 60947 | 240 A 40 ℃ - 10 s for power circuit 380 A 40 ℃ - 1 s for power circuit 50 A 40 ℃ - 10 min for power circuit 120 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 450 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 40 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 40 A 50 Hz for power circuit | 3.2 W AC-1 1.25 W AC-3 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 5.5 kW at 220...230 V AC 50/60 Hz (AC-3) 11 kW at 380...400 V AC 50/60 Hz (AC-3) 11 kW at 415...440 V AC 50/60 Hz (AC-3) 15 kW at 500 V AC 50/60 Hz (AC-3) 15 kW at 660...690 V AC 50/60 Hz (AC-3) 5.5 kW at 400 V AC 50/60 Hz (AC-4) | 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors 2 hp at 115 V AC 50/60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors 15 hp at 460/480 V AC 50/60 Hz for 3 phases motors 20 hp at 575/600 V AC 50/60 Hz for 3 phases motors 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 200 to 240 V 3 phases 7 to 11 kW at 380 to 440 V 3 phases 7 to 11 kW at 480 to 500 V 3 phases 2.2 to 3 kW at 100 to 120 V 3 phases 15 to 25 kW at 525 to 690 V 3 phases | - | - | - | - | - | - | - |
| LC1D25E7 | Contactor | LC1D | 1.65 Mcycles 25 A AC-3 at Ue <= 440 V 1.4 Mcycles 40 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.37 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | RINA GOST BV CCC DNV UL GL CSA LROS (Lloyds register of shipping) | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 48 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 40 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 40 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 450 A at 440 V for power circuit conforming to IEC 60947 | 240 A 40 ℃ - 10 s for power circuit 380 A 40 ℃ - 1 s for power circuit 50 A 40 ℃ - 10 min for power circuit 120 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 450 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 40 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 40 A 50 Hz for power circuit | 3.2 W AC-1 1.25 W AC-3 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 5.5 kW at 220...230 V AC 50/60 Hz (AC-3) 11 kW at 380...400 V AC 50/60 Hz (AC-3) 11 kW at 415...440 V AC 50/60 Hz (AC-3) 15 kW at 500 V AC 50/60 Hz (AC-3) 15 kW at 660...690 V AC 50/60 Hz (AC-3) 5.5 kW at 400 V AC 50/60 Hz (AC-4) | 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors 2 hp at 115 V AC 50/60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors 15 hp at 460/480 V AC 50/60 Hz for 3 phases motors 20 hp at 575/600 V AC 50/60 Hz for 3 phases motors 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 200 to 240 V 3 phases 7 to 11 kW at 380 to 440 V 3 phases 7 to 11 kW at 480 to 500 V 3 phases | 48 V AC standard | - | - | - | - | - | - |
| LC1D25ED | Contactor | LC1D | 1.65 Mcycles 25 A AC-3 at Ue <= 440 V 1.4 Mcycles 40 A AC-1 at Ue <= 440 V | 30 Mcycles | 45 mm | 85 mm | 101 mm | 0.53 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CCC BV RINA GL LROS (Lloyds register of shipping) GOST DNV UL CSA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-1 AC-3 | 48 V DC | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 40 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 40 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 450 A at 440 V for power circuit conforming to IEC 60947 | 240 A 40 ℃ - 10 s for power circuit 380 A 40 ℃ - 1 s for power circuit 50 A 40 ℃ - 10 min for power circuit 120 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | DC standard | 450 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 40 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 40 A 50 Hz for power circuit | 3.2 W AC-1 1.25 W AC-3 | 53.55...72.45 ms closing 16...24 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Built-in bidirectional peak limiting diode suppressor | LC1D | M4 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | - | - | - | Yes | Yes | End of Life Information | 5.5 kW at 220...230 V AC 50/60 Hz (AC-3) 11 kW at 380...400 V AC 50/60 Hz (AC-3) 11 kW at 415...440 V AC 50/60 Hz (AC-3) 15 kW at 500 V AC 50/60 Hz (AC-3) 15 kW at 660...690 V AC 50/60 Hz (AC-3) 5.5 kW at 400 V AC 50/60 Hz (AC-4) | 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors 2 hp at 115 V AC 50/60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors 15 hp at 460/480 V AC 50/60 Hz for 3 phases motors 20 hp at 575/600 V AC 50/60 Hz for 3 phases motors 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 200 to 240 V 3 phases 7 to 11 kW at 380 to 440 V 3 phases 7 to 11 kW at 480 to 500 V 3 phases | 48 V DC standard | 5.4 W at 20 ℃ | 28 ms | 5.4 W (at 20 ℃) | - | - | - |
| LC1D25F7 | Contactor | LC1D | 1.65 Mcycles 25 A AC-3 at Ue <= 440 V 1.4 Mcycles 40 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.37 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | UL BV RINA CCC GL GOST DNV LROS (Lloyds register of shipping) CSA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 110 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 40 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 40 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 450 A at 440 V for power circuit conforming to IEC 60947 | 240 A 40 ℃ - 10 s for power circuit 380 A 40 ℃ - 1 s for power circuit 50 A 40 ℃ - 10 min for power circuit 120 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 450 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 40 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 40 A 50 Hz for power circuit | 3.2 W AC-1 1.25 W AC-3 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 5.5 kW at 220...230 V AC 50/60 Hz (AC-3) 11 kW at 380...400 V AC 50/60 Hz (AC-3) 11 kW at 415...440 V AC 50/60 Hz (AC-3) 15 kW at 500 V AC 50/60 Hz (AC-3) 15 kW at 660...690 V AC 50/60 Hz (AC-3) 5.5 kW at 400 V AC 50/60 Hz (AC-4) | 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors 2 hp at 115 V AC 50/60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors 15 hp at 460/480 V AC 50/60 Hz for 3 phases motors 20 hp at 575/600 V AC 50/60 Hz for 3 phases motors 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 200 to 240 V 3 phases 7 to 11 kW at 380 to 440 V 3 phases 7 to 11 kW at 480 to 500 V 3 phases | 110 V AC standard | - | - | - | - | - | - |
| LC1D25M7 | Contactor | LC1D | 1.65 Mcycles 25 A AC-3 at Ue <= 440 V 1.4 Mcycles 40 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.37 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | BV GL LROS (Lloyds register of shipping) GOST UL DNV CCC CSA RINA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-3 AC-4 | 220 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 40 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 40 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 450 A at 440 V for power circuit conforming to IEC 60947 | 240 A 40 ℃ - 10 s for power circuit 380 A 40 ℃ - 1 s for power circuit 50 A 40 ℃ - 10 min for power circuit 120 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 450 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 40 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 40 A 50 Hz for power circuit | 3.2 W AC-1 1.25 W AC-3 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 5.5 kW at 220...230 V AC 50/60 Hz (AC-3) 11 kW at 380...400 V AC 50/60 Hz (AC-3) 11 kW at 415...440 V AC 50/60 Hz (AC-3) 15 kW at 500 V AC 50/60 Hz (AC-3) 15 kW at 660...690 V AC 50/60 Hz (AC-3) 5.5 kW at 400 V AC 50/60 Hz (AC-4) | 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors 2 hp at 115 V AC 50/60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors 15 hp at 460/480 V AC 50/60 Hz for 3 phases motors 20 hp at 575/600 V AC 50/60 Hz for 3 phases motors 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 4 to 6 kW at 200 to 240 V 3 phases 7 to 11 kW at 380 to 440 V 3 phases 7 to 11 kW at 480 to 500 V 3 phases | 220 V AC standard | - | - | - | - | - | - |
| LC1D32BL | Contactor | LC1D | 1.65 Mcycles 32 A AC-3 at Ue <= 440 V 1.4 Mcycles 50 A AC-1 at Ue <= 440 V | 30 Mcycles | 45 mm | 85 mm | 101 mm | 0.535 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | DNV RINA BV GL LROS (Lloyds register of shipping) CCC GOST CSA UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-1 AC-4 | 24 V DC | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 50 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 32 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 50 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 550 A at 440 V for power circuit conforming to IEC 60947 | 260 A 40 ℃ - 10 s for power circuit 430 A 40 ℃ - 1 s for power circuit 60 A 40 ℃ - 10 min for power circuit 138 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | DC low consumption | 550 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 50 A 50 Hz for power circuit | 2 W AC-3 5 W AC-1 | 65.45...88.55 ms closing 20...30 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Built-in bidirectional peak limiting diode suppressor | LC1D | M5 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | - | - | - | - | - | End of Life Information | 7.5 kW at 220...230 V AC 50/60 Hz (AC-3) 15 kW at 380...400 V AC 50/60 Hz (AC-3) 15 kW at 415...440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660...690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC-4) | 2 hp at 115 V AC 50/60 Hz for 1 phase motors 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 20 hp at 460/480 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 480 to 500 V 3 phases | 24 V DC low consumption | 2.4 W at 20 ℃ | 40 ms | 2.4 W (at 20 ℃) | - | - | - |
| LC1D32D7 | Contactor | LC1D | 1.65 Mcycles 32 A AC-3 at Ue <= 440 V 1.4 Mcycles 50 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.375 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | UL CSA GL GOST RINA DNV BV LROS (Lloyds register of shipping) CCC | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 42 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 50 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 32 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 50 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 550 A at 440 V for power circuit conforming to IEC 60947 | 260 A 40 ℃ - 10 s for power circuit 430 A 40 ℃ - 1 s for power circuit 60 A 40 ℃ - 10 min for power circuit 138 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 550 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 50 A 50 Hz for power circuit | 2 W AC-3 5 W AC-1 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 7.5 kW at 220...230 V AC 50/60 Hz (AC-3) 15 kW at 380...400 V AC 50/60 Hz (AC-3) 15 kW at 415...440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660...690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC-4) | 2 hp at 115 V AC 50/60 Hz for 1 phase motors 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 20 hp at 460/480 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 2.2 to 3 kW at 100 to 120 V 3 phases 15 to 25 kW at 525 to 690 V 3 phases 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 480 to 500 V 3 phases | - | - | - | - | - | - | - |
| LC1D32E7 | Contactor | LC1D | 1.65 Mcycles 32 A AC-3 at Ue <= 440 V 1.4 Mcycles 50 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.375 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | LROS (Lloyds register of shipping) GL GOST RINA DNV CCC UL BV CSA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-1 AC-3 | 48 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 50 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 32 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 50 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 550 A at 440 V for power circuit conforming to IEC 60947 | 260 A 40 ℃ - 10 s for power circuit 430 A 40 ℃ - 1 s for power circuit 60 A 40 ℃ - 10 min for power circuit 138 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 550 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 50 A 50 Hz for power circuit | 2 W AC-3 5 W AC-1 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 7.5 kW at 220...230 V AC 50/60 Hz (AC-3) 15 kW at 380...400 V AC 50/60 Hz (AC-3) 15 kW at 415...440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660...690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC-4) | 2 hp at 115 V AC 50/60 Hz for 1 phase motors 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 20 hp at 460/480 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 480 to 500 V 3 phases | 48 V AC standard | - | - | - | - | - | - |
| LC1D32F7 | Contactor | LC1D | 1.65 Mcycles 32 A AC-3 at Ue <= 440 V 1.4 Mcycles 50 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.375 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GOST BV LROS (Lloyds register of shipping) RINA CCC DNV UL CSA GL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-3 AC-4 | 110 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 50 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 32 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 50 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 550 A at 440 V for power circuit conforming to IEC 60947 | 260 A 40 ℃ - 10 s for power circuit 430 A 40 ℃ - 1 s for power circuit 60 A 40 ℃ - 10 min for power circuit 138 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 550 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 50 A 50 Hz for power circuit | 2 W AC-3 5 W AC-1 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 7.5 kW at 220...230 V AC 50/60 Hz (AC-3) 15 kW at 380...400 V AC 50/60 Hz (AC-3) 15 kW at 415...440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660...690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC-4) | 2 hp at 115 V AC 50/60 Hz for 1 phase motors 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 20 hp at 460/480 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 480 to 500 V 3 phases | 110 V AC standard | - | - | - | - | - | - |
| LC1D32M7 | Contactor | LC1D | 1.65 Mcycles 32 A AC-3 at Ue <= 440 V 1.4 Mcycles 50 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.375 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | DNV RINA LROS (Lloyds register of shipping) CCC CSA GL GOST BV UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-1 AC-3 | 220 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 50 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 32 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 50 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 550 A at 440 V for power circuit conforming to IEC 60947 | 260 A 40 ℃ - 10 s for power circuit 430 A 40 ℃ - 1 s for power circuit 60 A 40 ℃ - 10 min for power circuit 138 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 550 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 50 A 50 Hz for power circuit | 2 W AC-3 5 W AC-1 | 12...22 ms closing 4...19 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 7.5 kW at 220...230 V AC 50/60 Hz (AC-3) 15 kW at 380...400 V AC 50/60 Hz (AC-3) 15 kW at 415...440 V AC 50/60 Hz (AC-3) 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660...690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC-4) | 2 hp at 115 V AC 50/60 Hz for 1 phase motors 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 20 hp at 460/480 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 480 to 500 V 3 phases | 220 V AC standard | - | - | - | - | - | - |
| LC1D38BD | Contactor | LC1D | 1.4 Mcycles 50 A AC-1 at Ue <= 440 V 1.4 Mcycles 38 A AC-3 at Ue <= 440 V | 30 Mcycles | 45 mm | 85 mm | 101 mm | 0.54 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | RINA GOST CSA BV DNV LROS (Lloyds register of shipping) UL CCC GL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-3 AC-1 | 24 V DC | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 50 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 50 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 38 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 550 A at 440 V for power circuit conforming to IEC 60947 | 60 A 40 ℃ - 10 min for power circuit 430 A 40 ℃ - 1 s for power circuit 150 A 40 ℃ - 1 min for power circuit 310 A 40 ℃ - 10 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | DC standard | 550 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 50 A 50 Hz for power circuit | 5 W AC-1 3 W AC-3 | 16...24 ms opening 53.55...72.45 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Built-in bidirectional peak limiting diode suppressor | LC1D | M4 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | - | - | - | - | - | End of Life Information | 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660...690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 380...400 V AC 50/60 Hz (AC-3) 9 kW at 220...230 V AC 50/60 Hz (AC-3) 18.5 kW at 415...440 V AC 50/60 Hz (AC-3) | 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 5 hp at 240 V AC 50/60 Hz for 1 phase motors 20 hp at 480 V AC 50/60 Hz for 3 phases motors 25 hp at 600 V AC 50/60 Hz for 3 phases motors | - | - | - | 5.4 W at 20 ℃ | 28 ms | 5.4 W (at 20 ℃) | - | - | - |
| LC1D38D7 | Contactor | LC1D | 1.4 Mcycles 50 A AC-1 at Ue <= 440 V 1.4 Mcycles 38 A AC-3 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.38 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | DNV LROS (Lloyds register of shipping) GOST RINA CCC CSA GL BV UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 42 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 50 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 50 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 38 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 550 A at 440 V for power circuit conforming to IEC 60947 | 60 A 40 ℃ - 10 min for power circuit 430 A 40 ℃ - 1 s for power circuit 150 A 40 ℃ - 1 min for power circuit 310 A 40 ℃ - 10 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 550 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 50 A 50 Hz for power circuit | 5 W AC-1 3 W AC-3 | 4...19 ms opening 12...22 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660...690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 380...400 V AC 50/60 Hz (AC-3) 9 kW at 220...230 V AC 50/60 Hz (AC-3) 18.5 kW at 415...440 V AC 50/60 Hz (AC-3) | 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 5 hp at 240 V AC 50/60 Hz for 1 phase motors 20 hp at 480 V AC 50/60 Hz for 3 phases motors 25 hp at 600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 480 to 500 V 3 phases 15 to 25 kW at 525 to 690 V 3 phases 4 to 6 kW at 100 to 120 V 3 phases | - | - | - | - | - | - | - |
| LC1D38E7 | Contactor | LC1D | 1.4 Mcycles 50 A AC-1 at Ue <= 440 V 1.4 Mcycles 38 A AC-3 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.38 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GOST DNV RINA CCC LROS (Lloyds register of shipping) BV GL CSA UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 48 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 50 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 50 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 38 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 550 A at 440 V for power circuit conforming to IEC 60947 | 60 A 40 ℃ - 10 min for power circuit 430 A 40 ℃ - 1 s for power circuit 150 A 40 ℃ - 1 min for power circuit 310 A 40 ℃ - 10 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 550 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 50 A 50 Hz for power circuit | 5 W AC-1 3 W AC-3 | 4...19 ms opening 12...22 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660...690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 380...400 V AC 50/60 Hz (AC-3) 9 kW at 220...230 V AC 50/60 Hz (AC-3) 18.5 kW at 415...440 V AC 50/60 Hz (AC-3) | 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 5 hp at 240 V AC 50/60 Hz for 1 phase motors 20 hp at 480 V AC 50/60 Hz for 3 phases motors 25 hp at 600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 480 to 500 V 3 phases 15 to 25 kW at 525 to 690 V 3 phases 4 to 6 kW at 100 to 120 V 3 phases | - | - | - | - | - | - | - |
| LC1D38F7 | Contactor | LC1D | 1.4 Mcycles 50 A AC-1 at Ue <= 440 V 1.4 Mcycles 38 A AC-3 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.38 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | UL DNV RINA BV CCC CSA LROS (Lloyds register of shipping) GL GOST | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-1 | 110 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 50 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 50 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 38 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 550 A at 440 V for power circuit conforming to IEC 60947 | 60 A 40 ℃ - 10 min for power circuit 430 A 40 ℃ - 1 s for power circuit 150 A 40 ℃ - 1 min for power circuit 310 A 40 ℃ - 10 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 550 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 50 A 50 Hz for power circuit | 5 W AC-1 3 W AC-3 | 4...19 ms opening 12...22 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 18.5 kW at 500 V AC 50/60 Hz 18.5 kW at 660...690 V AC 50/60 Hz 18.5 kW at 380...400 V AC 50/60 Hz 9 kW at 220...230 V AC 50/60 Hz 18.5 kW at 415...440 V AC 50/60 Hz | 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 5 hp at 240 V AC 50/60 Hz for 1 phase motors 20 hp at 480 V AC 50/60 Hz for 3 phases motors 25 hp at 600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 480 to 500 V 3 phases 15 to 25 kW at 525 to 690 V 3 phases 4 to 6 kW at 100 to 120 V 3 phases | - | - | - | - | - | - | - |
| LC1D38M7 | Contactor | LC1D | 1.4 Mcycles 50 A AC-1 at Ue <= 440 V 1.4 Mcycles 38 A AC-3 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.38 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | LROS (Lloyds register of shipping) BV GL DNV RINA CCC GOST UL CSA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 220 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 50 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 50 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 38 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 550 A at 440 V for power circuit conforming to IEC 60947 | 60 A 40 ℃ - 10 min for power circuit 430 A 40 ℃ - 1 s for power circuit 150 A 40 ℃ - 1 min for power circuit 310 A 40 ℃ - 10 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 550 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 50 A 50 Hz for power circuit | 5 W AC-1 3 W AC-3 | 4...19 ms opening 12...22 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660...690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 380...400 V AC 50/60 Hz (AC-3) 9 kW at 220...230 V AC 50/60 Hz (AC-3) 18.5 kW at 415...440 V AC 50/60 Hz (AC-3) | 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 5 hp at 240 V AC 50/60 Hz for 1 phase motors 20 hp at 480 V AC 50/60 Hz for 3 phases motors 25 hp at 600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 480 to 500 V 3 phases 15 to 25 kW at 525 to 690 V 3 phases 4 to 6 kW at 100 to 120 V 3 phases | - | - | - | - | - | - | - |
| LC1D38Q7 | Contactor | LC1D | 1.4 Mcycles 50 A AC-1 at Ue <= 440 V 1.4 Mcycles 38 A AC-3 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.38 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | UL RINA BV GL DNV LROS (Lloyds register of shipping) CSA GOST CCC | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-1 AC-3 | 380 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 50 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 10 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 to 6 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5 to 10 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5 to 10 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 50 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 38 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 550 A at 440 V for power circuit conforming to IEC 60947 | 60 A 40 ℃ - 10 min for power circuit 430 A 40 ℃ - 1 s for power circuit 150 A 40 ℃ - 1 min for power circuit 310 A 40 ℃ - 10 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 550 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 50 A 50 Hz for power circuit | 5 W AC-1 3 W AC-3 | 4...19 ms opening 12...22 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | 18.5 kW at 500 V AC 50/60 Hz (AC-3) 18.5 kW at 660...690 V AC 50/60 Hz (AC-3) 7.5 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 380...400 V AC 50/60 Hz (AC-3) 9 kW at 220...230 V AC 50/60 Hz (AC-3) 18.5 kW at 415...440 V AC 50/60 Hz (AC-3) | 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 5 hp at 240 V AC 50/60 Hz for 1 phase motors 20 hp at 480 V AC 50/60 Hz for 3 phases motors 25 hp at 600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 480 to 500 V 3 phases 15 to 25 kW at 525 to 690 V 3 phases 4 to 6 kW at 100 to 120 V 3 phases | - | - | - | - | - | - | - |
| LC1D40008D7 | Contactor | LC1D | 1.4 Mcycles 60 A AC-1 at Ue <= 440 V | 6 Mcycles | 85 mm | 127 mm | 125 mm | 1.44 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | UL RINA DNV LROS (Lloyds register of shipping) GL CCC BV CSA GOST | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 42 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on screw clamp terminals - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on screw clamp terminals - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 60 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 60 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 800 A at 440 V for power circuit conforming to IEC 60947 | 320 A 40 ℃ - 10 s for power circuit 720 A 40 ℃ - 1 s for power circuit 72 A 40 ℃ - 10 min for power circuit 165 A 40 ℃ - 1 min for power circuit | Resistive load | 2 NO + 2 NC | AC at 50/60 Hz | 800 A at 440 V for power circuit conforming to IEC 60947 | 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 60 A 50 Hz for power circuit | 5.4 W AC-1 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | Without | Without built-in suppressor module | - | - | - | - | - | - | - | - | - | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | - | - | - | - | - | - | - | - | -5 to 60 ℃ | Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 ℃) Operational: 0.8...1.1 Uc AC 50 Hz (at 60 ℃) Operational: 0.85...1.1 Uc AC 60 Hz (at 60 ℃) | -40 to 70 ℃ at Uc |
| LC1D40008E7 | Contactor | LC1D | 1.4 Mcycles 60 A AC-1 at Ue <= 440 V | 6 Mcycles | 85 mm | 127 mm | 125 mm | 1.44 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CCC CSA BV UL DNV RINA LROS (Lloyds register of shipping) GOST GL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 48 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on screw clamp terminals - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on screw clamp terminals - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 60 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 60 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 800 A at 440 V for power circuit conforming to IEC 60947 | 320 A 40 ℃ - 10 s for power circuit 720 A 40 ℃ - 1 s for power circuit 72 A 40 ℃ - 10 min for power circuit 165 A 40 ℃ - 1 min for power circuit | Resistive load | 2 NO + 2 NC | AC at 50/60 Hz | 800 A at 440 V for power circuit conforming to IEC 60947 | 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 60 A 50 Hz for power circuit | 5.4 W AC-1 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | Without | Without built-in suppressor module | LC1D | M1 | - | - | - | - | - | - | - | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | - | - | - | - | - | - | - | - | - | - | - |
| LC1D40008M7 | Contactor | LC1D | 1.4 Mcycles 60 A AC-1 at Ue <= 440 V | 6 Mcycles | 85 mm | 127 mm | 125 mm | 1.44 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | RINA GL UL GOST BV LROS (Lloyds register of shipping) DNV CCC CSA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 220 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on screw clamp terminals - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on screw clamp terminals - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 60 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 25 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 60 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 800 A at 440 V for power circuit conforming to IEC 60947 | 320 A 40 ℃ - 10 s for power circuit 720 A 40 ℃ - 1 s for power circuit 72 A 40 ℃ - 10 min for power circuit 165 A 40 ℃ - 1 min for power circuit | Resistive load | 2 NO + 2 NC | AC at 50/60 Hz | 800 A at 440 V for power circuit conforming to IEC 60947 | 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 60 A 50 Hz for power circuit | 5.4 W AC-1 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | Without | Without built-in suppressor module | LC1D | M1 | - | - | - | - | - | - | - | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | - | - | - | - | - | - | - | - | - | - | - |
| LC1D40ABD | Contactor | LC1D | 0.7 Mcycles 60 A AC-1 at Ue <= 440 V 1.5 Mcycles 40 A AC-3 at Ue <= 440 V | 10 Mcycles | 55 mm | 122 mm | 120 mm | 0.925 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CCC CSA GOST UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-3 AC-4 | 24 V DC | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 60 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 60 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 40 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 800 A at 440 V for power circuit conforming to IEC 60947 | 320 A 40 ℃ - 10 s for power circuit 720 A 40 ℃ - 1 s for power circuit 72 A 40 ℃ - 10 min for power circuit 165 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | DC standard | 800 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 60 A 50 Hz for power circuit | 2.4 W AC-3 5.4 W AC-1 | 42.5...57.5 ms closing 16...24 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Built-in bidirectional peak limiting diode suppressor | LC1D | M4 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | - | - | - | Yes | Yes | End of Life Information | 18.5 kW at 380...400 V AC 50/60 Hz (AC-3) 11 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 415...440 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 30 kW at 660...690 V AC 50/60 Hz (AC-3) 9 kW at 400 V AC 50/60 Hz (AC-4) | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 115 V AC 50/60 Hz for 1 phase motors 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 480 to 500 V 3 phases | 24 V DC standard | 7.4 W at 20 ℃ | 34 ms | 19 W (at 20 ℃) | - | - | - |
| LC1D40AD7 | Contactor | LC1D | 1.4 Mcycles 60 A AC-1 at Ue <= 440 V 1.5 Mcycles 40 A AC-3 at Ue <= 440 V | 6 Mcycles | 55 mm | 122 mm | 120 mm | 0.85 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CCC GOST UL CSA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-1 AC-3 | 42 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 60 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 60 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 40 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 800 A at 440 V for power circuit conforming to IEC 60947 | 320 A 40 ℃ - 10 s for power circuit 720 A 40 ℃ - 1 s for power circuit 72 A 40 ℃ - 10 min for power circuit 165 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 800 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 60 A 50 Hz for power circuit | 2.4 W AC-3 5.4 W AC-1 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | 18.5 kW at 380...400 V AC 50/60 Hz (AC-3) 11 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 415...440 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 30 kW at 660...690 V AC 50/60 Hz (AC-3) 9 kW at 400 V AC 50/60 Hz (AC-4) | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 115 V AC 50/60 Hz for 1 phase motors 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors | - | - | - | - | - | - | - | - | - |
| LC1D40AE7 | Contactor | LC1D | 1.4 Mcycles 60 A AC-1 at Ue <= 440 V 1.5 Mcycles 40 A AC-3 at Ue <= 440 V | 6 Mcycles | 55 mm | 122 mm | 120 mm | 0.85 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GOST CSA UL CCC | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-3 AC-4 | 48 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 60 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 60 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 40 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 800 A at 440 V for power circuit conforming to IEC 60947 | 320 A 40 ℃ - 10 s for power circuit 720 A 40 ℃ - 1 s for power circuit 72 A 40 ℃ - 10 min for power circuit 165 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 800 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 60 A 50 Hz for power circuit | 2.4 W AC-3 5.4 W AC-1 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | 18.5 kW at 380...400 V AC 50/60 Hz (AC-3) 11 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 415...440 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 30 kW at 660...690 V AC 50/60 Hz (AC-3) 9 kW at 400 V AC 50/60 Hz (AC-4) | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 115 V AC 50/60 Hz for 1 phase motors 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 480 to 500 V 3 phases | 48 V AC standard | - | - | - | - | - | - |
| LC1D40AF7 | Contactor | LC1D | 1.4 Mcycles 60 A AC-1 at Ue <= 440 V 1.5 Mcycles 40 A AC-3 at Ue <= 440 V | 6 Mcycles | 55 mm | 122 mm | 120 mm | 0.85 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CCC CSA GOST UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-3 AC-4 | 110 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 60 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 60 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 40 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 800 A at 440 V for power circuit conforming to IEC 60947 | 320 A 40 ℃ - 10 s for power circuit 720 A 40 ℃ - 1 s for power circuit 72 A 40 ℃ - 10 min for power circuit 165 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 800 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 60 A 50 Hz for power circuit | 2.4 W AC-3 5.4 W AC-1 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | 18.5 kW at 380...400 V AC 50/60 Hz (AC-3) 11 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 415...440 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 30 kW at 660...690 V AC 50/60 Hz (AC-3) 9 kW at 400 V AC 50/60 Hz (AC-4) | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 115 V AC 50/60 Hz for 1 phase motors 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 480 to 500 V 3 phases | 110 V AC standard | - | - | - | - | - | - |
| LC1D40AM7 | Contactor | LC1D | 1.4 Mcycles 60 A AC-1 at Ue <= 440 V 1.5 Mcycles 40 A AC-3 at Ue <= 440 V | 6 Mcycles | 55 mm | 122 mm | 120 mm | 0.85 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CCC GOST UL CSA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 220 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 60 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 60 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 40 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 800 A at 440 V for power circuit conforming to IEC 60947 | 320 A 40 ℃ - 10 s for power circuit 720 A 40 ℃ - 1 s for power circuit 72 A 40 ℃ - 10 min for power circuit 165 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 800 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 60 A 50 Hz for power circuit | 2.4 W AC-3 5.4 W AC-1 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | 18.5 kW at 380...400 V AC 50/60 Hz (AC-3) 11 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 415...440 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 30 kW at 660...690 V AC 50/60 Hz (AC-3) 9 kW at 400 V AC 50/60 Hz (AC-4) | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 115 V AC 50/60 Hz for 1 phase motors 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 480 to 500 V 3 phases | 220 V AC standard | - | - | - | - | - | - |
| LC1D40AQ7 | Contactor | LC1D | 1.4 Mcycles 60 A AC-1 at Ue <= 440 V 1.5 Mcycles 40 A AC-3 at Ue <= 440 V | 6 Mcycles | 55 mm | 122 mm | 120 mm | 0.85 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CCC GOST UL CSA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 380 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 60 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 60 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 40 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 800 A at 440 V for power circuit conforming to IEC 60947 | 320 A 40 ℃ - 10 s for power circuit 720 A 40 ℃ - 1 s for power circuit 72 A 40 ℃ - 10 min for power circuit 165 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 800 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 60 A 50 Hz for power circuit | 2.4 W AC-3 5.4 W AC-1 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | 18.5 kW at 380...400 V AC 50/60 Hz (AC-3) 11 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 415...440 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 30 kW at 660...690 V AC 50/60 Hz (AC-3) 9 kW at 400 V AC 50/60 Hz (AC-4) | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 115 V AC 50/60 Hz for 1 phase motors 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors | - | - | - | - | - | - | - | - | - |
| LC1D50AB7 | Contactor | LC1D | 1.45 Mcycles 50 A AC-3 at Ue <= 440 V 1.1 Mcycles 80 A AC-1 at Ue <= 440 V | 6 Mcycles | 55 mm | 122 mm | 120 mm | 0.855 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | DNV LROS (Lloyds register of shipping) CCC GOST BV RINA CSA UL GL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 24 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 80 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 50 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 80 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 900 A at 440 V for power circuit conforming to IEC 60947 | 400 A 40 ℃ - 10 s for power circuit 810 A 40 ℃ - 1 s for power circuit 84 A 40 ℃ - 10 min for power circuit 208 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 900 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 100 A gG at <= 690 V coordination type 1 for power circuit 100 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 80 A 50 Hz for power circuit | 3.7 W AC-3 9.6 W AC-1 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | 15 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 380...400 V AC 50/60 Hz (AC-3) 30 kW at 500 V AC 50/60 Hz (AC-3) 33 kW at 660...690 V AC 50/60 Hz (AC-3) 25 kW at 415 V AC 50/60 Hz (AC-3) 30 kW at 440 V AC 50/60 Hz (AC-3) 11 kW at 400 V AC 50/60 Hz (AC-4) | 3 hp at 115 V AC 50/60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 15 hp at 200/208 V AC 50/60 Hz for 3 phases motors 15 hp at 230/240 V AC 50/60 Hz for 3 phases motors 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors 40 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 200 to 240 V 3 phases 30 to 50 kW at 380 to 440 V 3 phases 30 to 50 kW at 480 to 500 V 3 phases | 24 V AC standard | - | - | - | - | - | - |
| LC1D50ABD | Contactor | LC1D | 1.45 Mcycles 50 A AC-3 at Ue <= 440 V 0.5 Mcycles 80 A AC-1 at Ue <= 440 V | 10 Mcycles | 55 mm | 122 mm | 120 mm | 0.93 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | UL GOST DNV LROS (Lloyds register of shipping) CCC GL CSA RINA BV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 24 V DC | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 80 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 50 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 80 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 900 A at 440 V for power circuit conforming to IEC 60947 | 400 A 40 ℃ - 10 s for power circuit 810 A 40 ℃ - 1 s for power circuit 84 A 40 ℃ - 10 min for power circuit 208 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | DC standard | 900 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 100 A gG at <= 690 V coordination type 1 for power circuit 100 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 80 A 50 Hz for power circuit | 3.7 W AC-3 9.6 W AC-1 | 42.5...57.5 ms closing 16...24 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Built-in bidirectional peak limiting diode suppressor | LC1D | M4 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | - | - | - | Yes | Yes | End of Life Information | 15 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 380...400 V AC 50/60 Hz (AC-3) 30 kW at 500 V AC 50/60 Hz (AC-3) 33 kW at 660...690 V AC 50/60 Hz (AC-3) 25 kW at 415 V AC 50/60 Hz (AC-3) 30 kW at 440 V AC 50/60 Hz (AC-3) 11 kW at 400 V AC 50/60 Hz (AC-4) | 3 hp at 115 V AC 50/60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 15 hp at 200/208 V AC 50/60 Hz for 3 phases motors 15 hp at 230/240 V AC 50/60 Hz for 3 phases motors 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors 40 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 200 to 240 V 3 phases 30 to 50 kW at 380 to 440 V 3 phases 30 to 50 kW at 480 to 500 V 3 phases | 24 V DC standard | 7.4 W at 20 ℃ | 34 ms | 19 W (at 20 ℃) | - | - | - |
| LC1D50AE7 | Contactor | LC1D | 1.45 Mcycles 50 A AC-3 at Ue <= 440 V 1.1 Mcycles 80 A AC-1 at Ue <= 440 V | 6 Mcycles | 55 mm | 122 mm | 120 mm | 0.855 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | RINA CCC BV GL UL LROS (Lloyds register of shipping) CSA DNV GOST | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 48 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 80 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 50 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 80 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 900 A at 440 V for power circuit conforming to IEC 60947 | 400 A 40 ℃ - 10 s for power circuit 810 A 40 ℃ - 1 s for power circuit 84 A 40 ℃ - 10 min for power circuit 208 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 900 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 100 A gG at <= 690 V coordination type 1 for power circuit 100 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 80 A 50 Hz for power circuit | 3.7 W AC-3 9.6 W AC-1 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | 15 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 380...400 V AC 50/60 Hz (AC-3) 30 kW at 500 V AC 50/60 Hz (AC-3) 33 kW at 660...690 V AC 50/60 Hz (AC-3) 25 kW at 415 V AC 50/60 Hz (AC-3) 30 kW at 440 V AC 50/60 Hz (AC-3) 11 kW at 400 V AC 50/60 Hz (AC-4) | 3 hp at 115 V AC 50/60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 15 hp at 200/208 V AC 50/60 Hz for 3 phases motors 15 hp at 230/240 V AC 50/60 Hz for 3 phases motors 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors 40 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 200 to 240 V 3 phases 30 to 50 kW at 380 to 440 V 3 phases 30 to 50 kW at 480 to 500 V 3 phases | 48 V AC standard | - | - | - | - | - | - |
| LC1D50AM7 | Contactor | LC1D | 1.45 Mcycles 50 A AC-3 at Ue <= 440 V 1.1 Mcycles 80 A AC-1 at Ue <= 440 V | 6 Mcycles | 55 mm | 122 mm | 120 mm | 0.855 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | RINA DNV CSA GOST BV GL UL CCC LROS (Lloyds register of shipping) | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 220 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 80 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 50 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 80 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 900 A at 440 V for power circuit conforming to IEC 60947 | 400 A 40 ℃ - 10 s for power circuit 810 A 40 ℃ - 1 s for power circuit 84 A 40 ℃ - 10 min for power circuit 208 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 900 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 100 A gG at <= 690 V coordination type 1 for power circuit 100 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 80 A 50 Hz for power circuit | 3.7 W AC-3 9.6 W AC-1 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | 15 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 380...400 V AC 50/60 Hz (AC-3) 30 kW at 500 V AC 50/60 Hz (AC-3) 33 kW at 660...690 V AC 50/60 Hz (AC-3) 25 kW at 415 V AC 50/60 Hz (AC-3) 30 kW at 440 V AC 50/60 Hz (AC-3) 11 kW at 400 V AC 50/60 Hz (AC-4) | 3 hp at 115 V AC 50/60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 15 hp at 200/208 V AC 50/60 Hz for 3 phases motors 15 hp at 230/240 V AC 50/60 Hz for 3 phases motors 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors 40 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 7 to 11 kW at 200 to 240 V 3 phases 15 to 25 kW at 380 to 440 V 3 phases 15 to 25 kW at 200 to 240 V 3 phases 30 to 50 kW at 380 to 440 V 3 phases 30 to 50 kW at 480 to 500 V 3 phases | 220 V AC standard | - | - | - | - | - | - |
| LC1D50AQ7 | Contactor | LC1D | 1.45 Mcycles 50 A AC-3 at Ue <= 440 V 1.1 Mcycles 80 A AC-1 at Ue <= 440 V | 6 Mcycles | 55 mm | 122 mm | 120 mm | 0.855 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | UL DNV CCC CSA BV LROS (Lloyds register of shipping) GOST GL RINA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-1 AC-3 | 380 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 80 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 50 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit 80 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 900 A at 440 V for power circuit conforming to IEC 60947 | 400 A 40 ℃ - 10 s for power circuit 810 A 40 ℃ - 1 s for power circuit 84 A 40 ℃ - 10 min for power circuit 208 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 900 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 100 A gG at <= 690 V coordination type 1 for power circuit 100 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 80 A 50 Hz for power circuit | 3.7 W AC-3 9.6 W AC-1 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | 15 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 380...400 V AC 50/60 Hz (AC-3) 30 kW at 500 V AC 50/60 Hz (AC-3) 33 kW at 660...690 V AC 50/60 Hz (AC-3) 25 kW at 415 V AC 50/60 Hz (AC-3) 30 kW at 440 V AC 50/60 Hz (AC-3) 11 kW at 400 V AC 50/60 Hz (AC-4) | 3 hp at 115 V AC 50/60 Hz for 1 phase motors 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 15 hp at 200/208 V AC 50/60 Hz for 3 phases motors 15 hp at 230/240 V AC 50/60 Hz for 3 phases motors 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors 40 hp at 575/600 V AC 50/60 Hz for 3 phases motors | - | - | - | - | - | - | - | - | - |
| LC1D65008E7 | Contactor | LC1D | 1.4 Mcycles 80 A AC-1 at Ue <= 440 V | 6 Mcycles | 85 mm | 127 mm | 125 mm | 1.45 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GL BV UL DNV LROS (Lloyds register of shipping) CCC CSA RINA GOST | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 48 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on screw clamp terminals - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on screw clamp terminals - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 80 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 25 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 80 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 1000 A at 440 V for power circuit conforming to IEC 60947 | 520 A 40 ℃ - 10 s for power circuit 900 A 40 ℃ - 1 s for power circuit 110 A 40 ℃ - 10 min for power circuit 260 A 40 ℃ - 1 min for power circuit | Resistive load | 2 NO + 2 NC | AC at 50/60 Hz | 1000 A at 440 V for power circuit conforming to IEC 60947 | 125 A gG at <= 690 V coordination type 1 for power circuit 125 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 80 A 50 Hz for power circuit | 9.6 W AC-1 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | Without | Without built-in suppressor module | LC1D | M1 | - | - | - | - | - | - | - | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | - | - | - | - | - | - | - | - | - | - | - |
| LC1D65008M7 | Contactor | LC1D | 1.4 Mcycles 80 A AC-1 at Ue <= 440 V | 6 Mcycles | 85 mm | 127 mm | 125 mm | 1.45 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | RINA BV CSA UL LROS (Lloyds register of shipping) CCC DNV GL GOST | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 220 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on screw clamp terminals - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on screw clamp terminals - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 80 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 25 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 80 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 1000 A at 440 V for power circuit conforming to IEC 60947 | 520 A 40 ℃ - 10 s for power circuit 900 A 40 ℃ - 1 s for power circuit 110 A 40 ℃ - 10 min for power circuit 260 A 40 ℃ - 1 min for power circuit | Resistive load | 2 NO + 2 NC | AC at 50/60 Hz | 1000 A at 440 V for power circuit conforming to IEC 60947 | 125 A gG at <= 690 V coordination type 1 for power circuit 125 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 80 A 50 Hz for power circuit | 9.6 W AC-1 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | Without | Without built-in suppressor module | LC1D | M1 | - | - | - | - | - | - | - | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | - | - | - | - | - | - | - | - | - | - | - |
| LC1D65AB7 | Contactor | LC1D | 1.4 Mcycles 80 A AC-1 at Ue <= 440 V 1.45 Mcycles 65 A AC-3 at Ue <= 440 V | 6 Mcycles | 55 mm | 122 mm | 120 mm | 0.86 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | UL CCC CSA GOST | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 AC-3 AC-4 | 24 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 80 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 80 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 65 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1000 A at 440 V for power circuit conforming to IEC 60947 | 520 A 40 ℃ - 10 s for power circuit 900 A 40 ℃ - 1 s for power circuit 110 A 40 ℃ - 10 min for power circuit 260 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 1000 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 125 A gG at <= 690 V coordination type 1 for power circuit 125 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 80 A 50 Hz for power circuit | 9.6 W AC-1 6.3 W AC-3 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | 11 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 220...230 V AC 50/60 Hz (AC-3) 30 kW at 380...400 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3) 37 kW at 660...690 V AC 50/60 Hz (AC-3) | 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors 5 hp at 115 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors 20 hp at 230/240 V AC 50/60 Hz for 3 phases motors 50 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 15 to 25 kW at 200 to 240 V 3 phases 30 to 50 kW at 380 to 440 V 3 phases 30 to 50 kW at 480 to 500 V 3 phases | 24 V AC standard | - | - | - | - | - | - |
| LC1D65ABD | Contactor | LC1D | 0.5 Mcycles 80 A AC-1 at Ue <= 440 V 1.45 Mcycles 65 A AC-3 at Ue <= 440 V | 10 Mcycles | 55 mm | 122 mm | 120 mm | 0.935 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GOST UL CCC CSA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 24 V DC | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 80 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 80 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 65 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1000 A at 440 V for power circuit conforming to IEC 60947 | 520 A 40 ℃ - 10 s for power circuit 900 A 40 ℃ - 1 s for power circuit 110 A 40 ℃ - 10 min for power circuit 260 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | DC standard | 1000 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 125 A gG at <= 690 V coordination type 1 for power circuit 125 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 80 A 50 Hz for power circuit | 9.6 W AC-1 6.3 W AC-3 | 42.5...57.5 ms closing 16...24 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Built-in bidirectional peak limiting diode suppressor | LC1D | M4 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | - | - | - | Yes | Yes | End of Life Information | 11 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 220...230 V AC 50/60 Hz (AC-3) 30 kW at 380...400 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3) 37 kW at 660...690 V AC 50/60 Hz (AC-3) | 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors 5 hp at 115 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors 20 hp at 230/240 V AC 50/60 Hz for 3 phases motors 50 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 15 to 25 kW at 200 to 240 V 3 phases 30 to 50 kW at 380 to 440 V 3 phases 30 to 50 kW at 480 to 500 V 3 phases | 24 V DC standard | 7.4 W at 20 ℃ | 34 ms | 19 W (at 20 ℃) | - | - | - |
| LC1D65AD7 | Contactor | LC1D | 1.4 Mcycles 80 A AC-1 at Ue <= 440 V 1.45 Mcycles 65 A AC-3 at Ue <= 440 V | 6 Mcycles | 55 mm | 122 mm | 120 mm | 0.86 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CCC CSA UL GOST | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-1 AC-4 | 42 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 80 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 80 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 65 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1000 A at 440 V for power circuit conforming to IEC 60947 | 520 A 40 ℃ - 10 s for power circuit 900 A 40 ℃ - 1 s for power circuit 110 A 40 ℃ - 10 min for power circuit 260 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 1000 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 125 A gG at <= 690 V coordination type 1 for power circuit 125 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 80 A 50 Hz for power circuit | 9.6 W AC-1 6.3 W AC-3 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | 11 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 220...230 V AC 50/60 Hz (AC-3) 30 kW at 380...400 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3) 37 kW at 660...690 V AC 50/60 Hz (AC-3) | 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors 5 hp at 115 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors 20 hp at 230/240 V AC 50/60 Hz for 3 phases motors 50 hp at 575/600 V AC 50/60 Hz for 3 phases motors | - | - | - | - | - | - | - | - | - |
| LC1D65AE7 | Contactor | LC1D | 1.4 Mcycles 80 A AC-1 at Ue <= 440 V 1.45 Mcycles 65 A AC-3 at Ue <= 440 V | 6 Mcycles | 55 mm | 122 mm | 120 mm | 0.86 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CSA CCC GOST UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 48 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 80 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: screw connection 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: screw connection 2 cable(s) 1 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 80 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 65 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1000 A at 440 V for power circuit conforming to IEC 60947 | 520 A 40 ℃ - 10 s for power circuit 900 A 40 ℃ - 1 s for power circuit 110 A 40 ℃ - 10 min for power circuit 260 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 1000 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 125 A gG at <= 690 V coordination type 1 for power circuit 125 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 80 A 50 Hz for power circuit | 9.6 W AC-1 6.3 W AC-3 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | 11 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 220...230 V AC 50/60 Hz (AC-3) 30 kW at 380...400 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3) 37 kW at 660...690 V AC 50/60 Hz (AC-3) | 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors 5 hp at 115 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors 20 hp at 230/240 V AC 50/60 Hz for 3 phases motors 50 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 15 to 25 kW at 200 to 240 V 3 phases 30 to 50 kW at 380 to 440 V 3 phases 30 to 50 kW at 480 to 500 V 3 phases | 48 V AC standard | - | - | - | - | - | - |
| LC1D65AM7 | Contactor | LC1D | 1.4 Mcycles 80 A AC-1 at Ue <= 440 V 1.45 Mcycles 65 A AC-3 at Ue <= 440 V | 6 Mcycles | 55 mm | 122 mm | 120 mm | 0.86 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | UL CCC GOST CSA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 220 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25 to 35 mm2 hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1 to 25 mm2 hexagonal screw head 4 mm | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 80 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2flexible without cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2flexible without cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2flexible with cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2flexible with cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2solid without cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 80 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 65 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1000 A at 440 V for power circuit conforming to IEC 60947 | 520 A 40 ℃ - 10 s for power circuit 900 A 40 ℃ - 1 s for power circuit 110 A 40 ℃ - 10 min for power circuit 260 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 1000 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 125 A gG at <= 690 V coordination type 1 for power circuit 125 A gG at <= 690 V coordination type 2 for power circuit | 1.5 mOhm - Ith 80 A 50 Hz for power circuit | 9.6 W AC-1 6.3 W AC-3 | 4...19 ms opening 12...26 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M2 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 140 VA 60 Hz cos phi 0.75 (at 20 ℃) 160 VA 50 Hz cos phi 0.75 (at 20 ℃) | 13 VA 60 Hz cos phi 0.3 (at 20 ℃) 15 VA 50 Hz cos phi 0.3 (at 20 ℃) | 4 to 5 W at 50/60 Hz | Yes | Yes | End of Life Information | 11 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 220...230 V AC 50/60 Hz (AC-3) 30 kW at 380...400 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3) 37 kW at 660...690 V AC 50/60 Hz (AC-3) | 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors 5 hp at 115 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors 20 hp at 230/240 V AC 50/60 Hz for 3 phases motors 50 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 15 to 25 kW at 200 to 240 V 3 phases 30 to 50 kW at 380 to 440 V 3 phases 30 to 50 kW at 480 to 500 V 3 phases | 220 V AC standard | - | - | - | - | - | - |
| LC1D80008D7 | Contactor | LC1D | 0.8 Mcycles 125 A AC-1 at Ue <= 440 V | 4 Mcycles | 96 mm | 127 mm | 140 mm | 1.84 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GL DNV LROS (Lloyds register of shipping) BV UL RINA CCC CSA GOST | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 42 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 9 N.m - on connector - with screwdriver flat O 6 to O 8 mm Power circuit: 9 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: <= 300 V DC 25...400 Hz Power circuit: <= 690 V AC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 | 125 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2flexible without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible with cable end Power circuit: connector 2 cable(s) 4 to 16 mm2flexible with cable end Power circuit: connector 1 cable(s) 4 to 50 mm2solid without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 125 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 1100 A at 440 V for power circuit conforming to IEC 60947 | 640 A 40 ℃ - 10 s for power circuit 990 A 40 ℃ - 1 s for power circuit 135 A 40 ℃ - 10 min for power circuit 320 A 40 ℃ - 1 min for power circuit | Resistive load | 2 NO + 2 NC | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | 12.5 W AC-1 | 20...35 ms closing 6...20 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor open: 8 Gn for 11 ms Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | Without | Without built-in suppressor module | - | - | - | - | - | - | - | - | - | 245 VA 60 Hz cos phi 0.75 (at 20 ℃) 245 VA 50 Hz cos phi 0.75 (at 20 ℃) | 26 VA 60 Hz cos phi 0.3 (at 20 ℃) 26 VA 50 Hz cos phi 0.3 (at 20 ℃) | 6 to 10 W at 50/60 Hz | Yes | Yes | - | - | - | - | - | - | - | - | - | -5 to 60 ℃ | Operational: 0.85...1.1 Uc AC 60 Hz (at 55 ℃) Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 55 ℃) Operational: 0.8...1.1 Uc AC 50 Hz (at 55 ℃) | -40 to 70 ℃ at Uc |
| LC1D80008E7 | Contactor | LC1D | 0.8 Mcycles 125 A AC-1 at Ue <= 440 V | 4 Mcycles | 96 mm | 127 mm | 140 mm | 1.84 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CSA BV DNV GOST UL GL LROS (Lloyds register of shipping) RINA CCC | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 48 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 9 N.m - on connector - with screwdriver flat O 6 to O 8 mm Power circuit: 9 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: <= 300 V DC 25...400 Hz Power circuit: <= 690 V AC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 | 125 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2flexible without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible with cable end Power circuit: connector 2 cable(s) 4 to 16 mm2flexible with cable end Power circuit: connector 1 cable(s) 4 to 50 mm2solid without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 125 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 1100 A at 440 V for power circuit conforming to IEC 60947 | 640 A 40 ℃ - 10 s for power circuit 990 A 40 ℃ - 1 s for power circuit 135 A 40 ℃ - 10 min for power circuit 320 A 40 ℃ - 1 min for power circuit | Resistive load | 2 NO + 2 NC | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | 12.5 W AC-1 | 20...35 ms closing 6...20 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor open: 8 Gn for 11 ms Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | Without | Without built-in suppressor module | LC1D | M1 | - | - | - | - | - | - | - | 245 VA 60 Hz cos phi 0.75 (at 20 ℃) 245 VA 50 Hz cos phi 0.75 (at 20 ℃) | 26 VA 60 Hz cos phi 0.3 (at 20 ℃) 26 VA 50 Hz cos phi 0.3 (at 20 ℃) | 6 to 10 W at 50/60 Hz | Yes | Yes | - | - | - | - | - | - | - | - | - | - | - | - |
| LC1D80008M7 | Contactor | LC1D | 0.8 Mcycles 125 A AC-1 at Ue <= 440 V | 4 Mcycles | 96 mm | 127 mm | 140 mm | 1.84 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | RINA CSA BV DNV GOST LROS (Lloyds register of shipping) GL UL CCC | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 220 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 9 N.m - on connector - with screwdriver flat O 6 to O 8 mm Power circuit: 9 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: <= 300 V DC 25...400 Hz Power circuit: <= 690 V AC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 | 125 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2flexible without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible with cable end Power circuit: connector 2 cable(s) 4 to 16 mm2flexible with cable end Power circuit: connector 1 cable(s) 4 to 50 mm2solid without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 125 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 1100 A at 440 V for power circuit conforming to IEC 60947 | 640 A 40 ℃ - 10 s for power circuit 990 A 40 ℃ - 1 s for power circuit 135 A 40 ℃ - 10 min for power circuit 320 A 40 ℃ - 1 min for power circuit | Resistive load | 2 NO + 2 NC | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | 12.5 W AC-1 | 20...35 ms closing 6...20 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor open: 8 Gn for 11 ms Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | Without | Without built-in suppressor module | LC1D | M1 | - | - | - | - | - | - | - | 245 VA 60 Hz cos phi 0.75 (at 20 ℃) 245 VA 50 Hz cos phi 0.75 (at 20 ℃) | 26 VA 60 Hz cos phi 0.3 (at 20 ℃) 26 VA 50 Hz cos phi 0.3 (at 20 ℃) | 6 to 10 W at 50/60 Hz | Yes | Yes | - | - | - | - | - | - | - | - | - | - | - | - |
| LC1D80D7 | Contactor | LC1D | 0.8 Mcycles 125 A AC-1 at Ue <= 440 V 1.5 Mcycles 80 A AC-3 at Ue <= 440 V | 4 Mcycles | 85 mm | 127 mm | 130 mm | 1.59 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | RINA LROS (Lloyds register of shipping) GL DNV CSA BV UL GOST CCC | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-1 AC-4 | 42 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 9 N.m - on connector - with screwdriver flat O 6 to O 8 mm Power circuit: 9 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: <= 300 V DC 25...400 Hz Power circuit: <= 690 V AC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 125 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2flexible without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible with cable end Power circuit: connector 2 cable(s) 4 to 16 mm2flexible with cable end Power circuit: connector 1 cable(s) 4 to 50 mm2solid without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 125 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 80 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1100 A at 440 V for power circuit conforming to IEC 60947 | 640 A 40 ℃ - 10 s for power circuit 990 A 40 ℃ - 1 s for power circuit 135 A 40 ℃ - 10 min for power circuit 320 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | 5.1 W AC-3 12.5 W AC-1 | 20...35 ms closing 6...20 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor open: 8 Gn for 11 ms Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M11 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 245 VA 60 Hz cos phi 0.75 (at 20 ℃) 245 VA 50 Hz cos phi 0.75 (at 20 ℃) | 26 VA 60 Hz cos phi 0.3 (at 20 ℃) 26 VA 50 Hz cos phi 0.3 (at 20 ℃) | 6 to 10 W at 50/60 Hz | Yes | Yes | - | 22 kW at 220...230 V AC 50/60 Hz (AC-3) 37 kW at 380...400 V AC 50/60 Hz (AC-3) 45 kW at 415...440 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 660...690 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) | 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors 7.5 hp at 115 V AC 50/60 Hz for 1 phase motors 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors 25 hp at 230/240 V AC 50/60 Hz for 3 phases motors 60 hp at 460/480 V AC 50/60 Hz for 3 phases motors 60 hp at 575/600 V AC 50/60 Hz for 3 phases motors | - | - | - | - | - | - | - | - | - |
| LC1D80E7 | Contactor | LC1D | 0.8 Mcycles 125 A AC-1 at Ue <= 440 V 1.5 Mcycles 80 A AC-3 at Ue <= 440 V | 4 Mcycles | 85 mm | 127 mm | 130 mm | 1.59 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CSA BV UL GOST RINA CCC GL LROS (Lloyds register of shipping) DNV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-1 AC-4 | 48 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 9 N.m - on connector - with screwdriver flat O 6 to O 8 mm Power circuit: 9 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: <= 300 V DC 25...400 Hz Power circuit: <= 690 V AC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 125 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2flexible without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible with cable end Power circuit: connector 2 cable(s) 4 to 16 mm2flexible with cable end Power circuit: connector 1 cable(s) 4 to 50 mm2solid without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 125 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 80 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1100 A at 440 V for power circuit conforming to IEC 60947 | 640 A 40 ℃ - 10 s for power circuit 990 A 40 ℃ - 1 s for power circuit 135 A 40 ℃ - 10 min for power circuit 320 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | 5.1 W AC-3 12.5 W AC-1 | 20...35 ms closing 6...20 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor open: 8 Gn for 11 ms Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M11 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 245 VA 60 Hz cos phi 0.75 (at 20 ℃) 245 VA 50 Hz cos phi 0.75 (at 20 ℃) | 26 VA 60 Hz cos phi 0.3 (at 20 ℃) 26 VA 50 Hz cos phi 0.3 (at 20 ℃) | 6 to 10 W at 50/60 Hz | Yes | Yes | - | 22 kW at 220...230 V AC 50/60 Hz (AC-3) 37 kW at 380...400 V AC 50/60 Hz (AC-3) 45 kW at 415...440 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 660...690 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) | 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors 7.5 hp at 115 V AC 50/60 Hz for 1 phase motors 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors 25 hp at 230/240 V AC 50/60 Hz for 3 phases motors 60 hp at 460/480 V AC 50/60 Hz for 3 phases motors 60 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 55 to 100 kW at 480 to 500 V 3 phases 15 to 25 kW at 200 to 240 V 3 phases 30 to 50 kW at 380 to 440 V 3 phases 30 to 50 kW at 480 to 500 V 3 phases | 48 V AC standard | - | - | - | - | - | - |
| LC1D80F7 | Contactor | LC1D | 0.8 Mcycles 125 A AC-1 at Ue <= 440 V 1.5 Mcycles 80 A AC-3 at Ue <= 440 V | 4 Mcycles | 85 mm | 127 mm | 130 mm | 1.59 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GL RINA BV DNV LROS (Lloyds register of shipping) CCC GOST UL CSA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-1 AC-3 | 110 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 9 N.m - on connector - with screwdriver flat O 6 to O 8 mm Power circuit: 9 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: <= 300 V DC 25...400 Hz Power circuit: <= 690 V AC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 125 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2flexible without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible with cable end Power circuit: connector 2 cable(s) 4 to 16 mm2flexible with cable end Power circuit: connector 1 cable(s) 4 to 50 mm2solid without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 125 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 80 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1100 A at 440 V for power circuit conforming to IEC 60947 | 640 A 40 ℃ - 10 s for power circuit 990 A 40 ℃ - 1 s for power circuit 135 A 40 ℃ - 10 min for power circuit 320 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | 5.1 W AC-3 12.5 W AC-1 | 20...35 ms closing 6...20 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor open: 8 Gn for 11 ms Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M11 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 245 VA 60 Hz cos phi 0.75 (at 20 ℃) 245 VA 50 Hz cos phi 0.75 (at 20 ℃) | 26 VA 60 Hz cos phi 0.3 (at 20 ℃) 26 VA 50 Hz cos phi 0.3 (at 20 ℃) | 6 to 10 W at 50/60 Hz | Yes | Yes | - | 22 kW at 220...230 V AC 50/60 Hz (AC-3) 37 kW at 380...400 V AC 50/60 Hz (AC-3) 45 kW at 415...440 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 660...690 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) | 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors 7.5 hp at 115 V AC 50/60 Hz for 1 phase motors 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors 25 hp at 230/240 V AC 50/60 Hz for 3 phases motors 60 hp at 460/480 V AC 50/60 Hz for 3 phases motors 60 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 55 to 100 kW at 480 to 500 V 3 phases 15 to 25 kW at 200 to 240 V 3 phases 30 to 50 kW at 380 to 440 V 3 phases 30 to 50 kW at 480 to 500 V 3 phases | 110 V AC standard | - | - | - | - | - | - |
| LC1D80M7 | Contactor | LC1D | 0.8 Mcycles 125 A AC-1 at Ue <= 440 V 1.5 Mcycles 80 A AC-3 at Ue <= 440 V | 4 Mcycles | 85 mm | 127 mm | 130 mm | 1.59 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GOST RINA CCC CSA BV DNV GL LROS (Lloyds register of shipping) UL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 220 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 9 N.m - on connector - with screwdriver flat O 6 to O 8 mm Power circuit: 9 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: <= 300 V DC 25...400 Hz Power circuit: <= 690 V AC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 125 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2flexible without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible with cable end Power circuit: connector 2 cable(s) 4 to 16 mm2flexible with cable end Power circuit: connector 1 cable(s) 4 to 50 mm2solid without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 125 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 80 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1100 A at 440 V for power circuit conforming to IEC 60947 | 640 A 40 ℃ - 10 s for power circuit 990 A 40 ℃ - 1 s for power circuit 135 A 40 ℃ - 10 min for power circuit 320 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | 5.1 W AC-3 12.5 W AC-1 | 20...35 ms closing 6...20 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor open: 8 Gn for 11 ms Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M11 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 245 VA 60 Hz cos phi 0.75 (at 20 ℃) 245 VA 50 Hz cos phi 0.75 (at 20 ℃) | 26 VA 60 Hz cos phi 0.3 (at 20 ℃) 26 VA 50 Hz cos phi 0.3 (at 20 ℃) | 6 to 10 W at 50/60 Hz | Yes | Yes | - | 22 kW at 220...230 V AC 50/60 Hz (AC-3) 37 kW at 380...400 V AC 50/60 Hz (AC-3) 45 kW at 415...440 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 660...690 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) | 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors 7.5 hp at 115 V AC 50/60 Hz for 1 phase motors 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors 25 hp at 230/240 V AC 50/60 Hz for 3 phases motors 60 hp at 460/480 V AC 50/60 Hz for 3 phases motors 60 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 55 to 100 kW at 480 to 500 V 3 phases 15 to 25 kW at 200 to 240 V 3 phases 30 to 50 kW at 380 to 440 V 3 phases 30 to 50 kW at 480 to 500 V 3 phases | 220 V AC standard | - | - | - | - | - | - |
| LC1D80Q7 | Contactor | LC1D | 0.8 Mcycles 125 A AC-1 at Ue <= 440 V 1.5 Mcycles 80 A AC-3 at Ue <= 440 V | 4 Mcycles | 85 mm | 127 mm | 130 mm | 1.59 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | LROS (Lloyds register of shipping) DNV GL UL CSA GOST BV CCC RINA | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-3 AC-1 AC-4 | 380 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 9 N.m - on connector - with screwdriver flat O 6 to O 8 mm Power circuit: 9 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: <= 300 V DC 25...400 Hz Power circuit: <= 690 V AC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 125 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2flexible without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible with cable end Power circuit: connector 2 cable(s) 4 to 16 mm2flexible with cable end Power circuit: connector 1 cable(s) 4 to 50 mm2solid without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 125 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 80 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1100 A at 440 V for power circuit conforming to IEC 60947 | 640 A 40 ℃ - 10 s for power circuit 990 A 40 ℃ - 1 s for power circuit 135 A 40 ℃ - 10 min for power circuit 320 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | 5.1 W AC-3 12.5 W AC-1 | 20...35 ms closing 6...20 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor open: 8 Gn for 11 ms Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M11 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 245 VA 60 Hz cos phi 0.75 (at 20 ℃) 245 VA 50 Hz cos phi 0.75 (at 20 ℃) | 26 VA 60 Hz cos phi 0.3 (at 20 ℃) 26 VA 50 Hz cos phi 0.3 (at 20 ℃) | 6 to 10 W at 50/60 Hz | Yes | Yes | - | 22 kW at 220...230 V AC 50/60 Hz (AC-3) 37 kW at 380...400 V AC 50/60 Hz (AC-3) 45 kW at 415...440 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 660...690 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) | 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors 7.5 hp at 115 V AC 50/60 Hz for 1 phase motors 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors 25 hp at 230/240 V AC 50/60 Hz for 3 phases motors 60 hp at 460/480 V AC 50/60 Hz for 3 phases motors 60 hp at 575/600 V AC 50/60 Hz for 3 phases motors | - | - | - | - | - | - | - | - | - |
| LC1D95B7 | Contactor | LC1D | 1.2 Mcycles 95 A AC-3 1.3 Mcycles 125 A AC-1 | 4 Mcycles | 85 mm | 127 mm | 130 mm | 1.61 kg | IP20 front face conforming to IEC 60529 | 3 | EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 | -60 to 80 ℃ | IECEE CB Scheme UL CSA CCC EAC LROS (Lloyds register of shipping) RINA BV DNV-GL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0...3000 m | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 24 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 9 N.m - on connector - with screwdriver flat O 6 to O 8 mm Power circuit: 9 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: 1000 V AC 25...400 Hz | Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 125 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2flexible without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible with cable end Power circuit: connector 2 cable(s) 4 to 16 mm2flexible with cable end Power circuit: connector 1 cable(s) 4 to 50 mm2solid without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 95 A (at <60 ℃) at <= 440 V AC-3 for power circuit 125 A (at <60 ℃) at <= 690 V AC-1 for power circuit | Plate Rail | 1100 A at 440 V AC for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 1100 A 40 ℃ - 1 s for power circuit 800 A 40 ℃ - 10 s for power circuit 400 A 40 ℃ - 1 min for power circuit 135 A 40 ℃ - 10 min for power circuit 140 A - 100 ms for signalling circuit 120 A - 500 ms for signalling circuit 100 A - 1 s for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | 12.5 W AC-1 7.2 W AC-3 | 20...35 ms closing 6...20 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor open: 8 Gn for 11 ms Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms | B10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M11 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 245 VA 60 Hz cos phi 0.75 (at 20 ℃) 245 VA 50 Hz cos phi 0.75 (at 20 ℃) | 26 VA 60 Hz cos phi 0.3 (at 20 ℃) 26 VA 50 Hz cos phi 0.3 (at 20 ℃) | 6 to 10 W at 50/60 Hz | Yes | Yes | - | 25 kW at 220...230 V AC 50 Hz (AC-3) 45 kW at 380...400 V AC 50 Hz (AC-3) 45 kW at 415...440 V AC 50 Hz (AC-3) 55 kW at 500 V AC 50 Hz (AC-3) 45 kW at 660...690 V AC 50 Hz (AC-3) 45 kW at 1000 V AC 50 Hz (AC-3) | 7.5 hp at 115 V AC 60 Hz for 1 phase motors 15 hp at 230/240 V AC 60 Hz for 1 phase motors 25 hp at 200/208 V AC 60 Hz for 3 phases motors 30 hp at 230/240 V AC 60 Hz for 3 phases motors 60 hp at 460/480 V AC 60 Hz for 3 phases motors 60 hp at 575/600 V AC 60 Hz for 3 phases motors | Direct on-line contactor | 55 to 100 kW at 480 to 500 V 3 phases 15 to 25 kW at 200 to 240 V 3 phases 30 to 50 kW at 380 to 440 V 3 phases 30 to 50 kW at 480 to 500 V 3 phases | 24 V AC standard | - | - | - | - | - | - |
| LC1D95BD | Contactor | LC1D | 1.2 Mcycles 95 A AC-3 1.3 Mcycles 125 A AC-1 | 10 Mcycles | 85 mm | 127 mm | 186 mm | 2.61 kg | IP20 front face conforming to IEC 60529 | 3 | EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.4 | -60 to 80 ℃ | IECEE CB Scheme CCC EAC LROS (Lloyds register of shipping) RINA BV DNV-GL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0...3000 m | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 24 V DC | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 9 N.m - on connector - with screwdriver flat O 6 to O 8 mm Power circuit: 9 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: 1000 V AC 25...400 Hz | Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 | 10 A (at 60 ℃) for signalling circuit 125 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2flexible without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible with cable end Power circuit: connector 2 cable(s) 4 to 16 mm2flexible with cable end Power circuit: connector 1 cable(s) 4 to 50 mm2solid without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 95 A (at <60 ℃) at <= 440 V AC-3 for power circuit 125 A (at <60 ℃) at <= 690 V AC-1 for power circuit | Rail Plate | 1100 A at 440 V AC for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 1100 A 40 ℃ - 1 s for power circuit 800 A 40 ℃ - 10 s for power circuit 400 A 40 ℃ - 1 min for power circuit 135 A 40 ℃ - 10 min for power circuit 140 A - 100 ms for signalling circuit 120 A - 500 ms for signalling circuit 100 A - 1 s for signalling circuit | Resistive load Motor control | 3 NO | DC standard | 1100 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | 12.5 W AC-1 7.2 W AC-3 | 95...130 ms closing 20...35 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor open: 8 Gn for 11 ms Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms | B10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M9 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | - | - | - | Yes | Yes | - | 25 kW at 220...230 V AC 50 Hz (AC-3) 45 kW at 380...400 V AC 50 Hz (AC-3) 45 kW at 415...440 V AC 50 Hz (AC-3) 55 kW at 500 V AC 50 Hz (AC-3) 45 kW at 660...690 V AC 50 Hz (AC-3) 45 kW at 1000 V AC 50 Hz (AC-3) | 7.5 hp at 115 V AC 60 Hz for 1 phase motors 15 hp at 230/240 V AC 60 Hz for 1 phase motors 25 hp at 200/208 V AC 60 Hz for 3 phases motors 30 hp at 230/240 V AC 60 Hz for 3 phases motors 60 hp at 460/480 V AC 60 Hz for 3 phases motors 60 hp at 575/600 V AC 60 Hz for 3 phases motors | Direct on-line contactor | 55 to 100 kW at 480 to 500 V 3 phases 15 to 25 kW at 200 to 240 V 3 phases 30 to 50 kW at 380 to 440 V 3 phases 30 to 50 kW at 480 to 500 V 3 phases | 24 V DC standard | 22 W at 20 ℃ | 75 ms | 22 W (at 20 ℃) | - | - | - |
| LC1D95E7 | Contactor | LC1D | 1.2 Mcycles 95 A AC-3 at Ue <= 440 V 1.3 Mcycles 125 A AC-1 at Ue <= 440 V | 4 Mcycles | 85 mm | 127 mm | 130 mm | 1.61 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | RINA GOST DNV GL CCC LROS (Lloyds register of shipping) BV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-4 AC-1 AC-3 | 48 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 9 N.m - on connector - with screwdriver flat O 6 to O 8 mm Power circuit: 9 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: <= 300 V DC 25...400 Hz | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 125 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2flexible without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible with cable end Power circuit: connector 2 cable(s) 4 to 16 mm2flexible with cable end Power circuit: connector 1 cable(s) 4 to 50 mm2solid without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 125 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit 95 A (at <60 ℃) at <= 440 V AC AC-3 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1100 A at 440 V for power circuit conforming to IEC 60947 | 1100 A 40 ℃ - 1 s for power circuit 135 A 40 ℃ - 10 min for power circuit 800 A 40 ℃ - 10 s for power circuit 400 A 40 ℃ - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | 12.5 W AC-1 7.2 W AC-3 | 20...35 ms closing 6...20 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor open: 8 Gn for 11 ms Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M11 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 245 VA 60 Hz cos phi 0.75 (at 20 ℃) 245 VA 50 Hz cos phi 0.75 (at 20 ℃) | 26 VA 60 Hz cos phi 0.3 (at 20 ℃) 26 VA 50 Hz cos phi 0.3 (at 20 ℃) | 6 to 10 W at 50/60 Hz | Yes | Yes | - | 45 kW at 415...440 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 660...690 V AC 50/60 Hz (AC-3) 45 kW at 1000 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 25 kW at 220...230 V AC 50/60 Hz (AC-3) | 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors 7.5 hp at 115 V AC 50/60 Hz for 1 phase motors 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors 25 hp at 230/240 V AC 50/60 Hz for 3 phases motors 60 hp at 460/480 V AC 50/60 Hz for 3 phases motors 60 hp at 575/600 V AC 50/60 Hz for 3 phases motors | Direct on-line contactor | 55 to 100 kW at 480 to 500 V 3 phases 15 to 25 kW at 200 to 240 V 3 phases 30 to 50 kW at 380 to 440 V 3 phases 30 to 50 kW at 480 to 500 V 3 phases | 48 V AC standard | - | - | - | - | - | - |
| LC1D95M7 | Contactor | LC1D | 1.2 Mcycles 95 A AC-3 1.3 Mcycles 125 A AC-1 | 4 Mcycles | 85 mm | 127 mm | 130 mm | 1.61 kg | IP20 front face conforming to IEC 60529 | 3 | EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 | -60 to 80 ℃ | IECEE CB Scheme UL CSA CCC EAC LROS (Lloyds register of shipping) RINA BV DNV-GL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0...3000 m | REACH Declaration | 18 months | AC-1 AC-4 AC-3 | 220 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 9 N.m - on connector - with screwdriver flat O 6 to O 8 mm Power circuit: 9 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: 1000 V AC 25...400 Hz | Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 125 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2flexible without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible with cable end Power circuit: connector 2 cable(s) 4 to 16 mm2flexible with cable end Power circuit: connector 1 cable(s) 4 to 50 mm2solid without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 95 A (at <60 ℃) at <= 440 V AC-3 for power circuit 125 A (at <60 ℃) at <= 690 V AC-1 for power circuit | Rail Plate | 1100 A at 440 V AC for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 1100 A 40 ℃ - 1 s for power circuit 800 A 40 ℃ - 10 s for power circuit 400 A 40 ℃ - 1 min for power circuit 135 A 40 ℃ - 10 min for power circuit 140 A - 100 ms for signalling circuit 120 A - 500 ms for signalling circuit 100 A - 1 s for signalling circuit | Motor control Resistive load | 3 NO | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | 12.5 W AC-1 7.2 W AC-3 | 20...35 ms closing 6...20 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor open: 8 Gn for 11 ms Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms | B10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M11 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 245 VA 60 Hz cos phi 0.75 (at 20 ℃) 245 VA 50 Hz cos phi 0.75 (at 20 ℃) | 26 VA 60 Hz cos phi 0.3 (at 20 ℃) 26 VA 50 Hz cos phi 0.3 (at 20 ℃) | 6 to 10 W at 50/60 Hz | Yes | Yes | - | 25 kW at 220...230 V AC 50 Hz (AC-3) 45 kW at 380...400 V AC 50 Hz (AC-3) 45 kW at 415...440 V AC 50 Hz (AC-3) 55 kW at 500 V AC 50 Hz (AC-3) 45 kW at 660...690 V AC 50 Hz (AC-3) 45 kW at 1000 V AC 50 Hz (AC-3) | 7.5 hp at 115 V AC 60 Hz for 1 phase motors 15 hp at 230/240 V AC 60 Hz for 1 phase motors 25 hp at 200/208 V AC 60 Hz for 3 phases motors 30 hp at 230/240 V AC 60 Hz for 3 phases motors 60 hp at 460/480 V AC 60 Hz for 3 phases motors 60 hp at 575/600 V AC 60 Hz for 3 phases motors | Direct on-line contactor | 55 to 100 kW at 480 to 500 V 3 phases 15 to 25 kW at 200 to 240 V 3 phases 30 to 50 kW at 380 to 440 V 3 phases 30 to 50 kW at 480 to 500 V 3 phases | 220 V AC standard | - | - | - | - | - | - |
| LC1D95P7 | Contactor | LC1D | 1.2 Mcycles 95 A AC-3 1.3 Mcycles 125 A AC-1 | 4 Mcycles | 85 mm | 127 mm | 130 mm | 1.61 kg | IP20 front face conforming to IEC 60529 | 3 | EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 | -60 to 80 ℃ | IECEE CB Scheme UL CSA CCC EAC LROS (Lloyds register of shipping) RINA BV DNV-GL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0...3000 m | REACH Declaration | 18 months | AC-1 AC-3 AC-4 | 230 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 9 N.m - on connector - with screwdriver flat O 6 to O 8 mm Power circuit: 9 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: 1000 V AC 25...400 Hz | Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 125 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2flexible without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible with cable end Power circuit: connector 2 cable(s) 4 to 16 mm2flexible with cable end Power circuit: connector 1 cable(s) 4 to 50 mm2solid without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 95 A (at <60 ℃) at <= 440 V AC-3 for power circuit 125 A (at <60 ℃) at <= 690 V AC-1 for power circuit | Plate Rail | 1100 A at 440 V AC for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 1100 A 40 ℃ - 1 s for power circuit 800 A 40 ℃ - 10 s for power circuit 400 A 40 ℃ - 1 min for power circuit 135 A 40 ℃ - 10 min for power circuit 140 A - 100 ms for signalling circuit 120 A - 500 ms for signalling circuit 100 A - 1 s for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | 12.5 W AC-1 7.2 W AC-3 | 20...35 ms closing 6...20 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor open: 8 Gn for 11 ms Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms | B10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M11 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 245 VA 60 Hz cos phi 0.75 (at 20 ℃) 245 VA 50 Hz cos phi 0.75 (at 20 ℃) | 26 VA 60 Hz cos phi 0.3 (at 20 ℃) 26 VA 50 Hz cos phi 0.3 (at 20 ℃) | 6 to 10 W at 50/60 Hz | Yes | Yes | - | 25 kW at 220...230 V AC 50 Hz (AC-3) 45 kW at 380...400 V AC 50 Hz (AC-3) 45 kW at 415...440 V AC 50 Hz (AC-3) 55 kW at 500 V AC 50 Hz (AC-3) 45 kW at 660...690 V AC 50 Hz (AC-3) 45 kW at 1000 V AC 50 Hz (AC-3) | 7.5 hp at 115 V AC 60 Hz for 1 phase motors 15 hp at 230/240 V AC 60 Hz for 1 phase motors 25 hp at 200/208 V AC 60 Hz for 3 phases motors 30 hp at 230/240 V AC 60 Hz for 3 phases motors 60 hp at 460/480 V AC 60 Hz for 3 phases motors 60 hp at 575/600 V AC 60 Hz for 3 phases motors | Direct on-line contactor | 55 to 100 kW at 480 to 500 V 3 phases 15 to 25 kW at 200 to 240 V 3 phases 30 to 50 kW at 380 to 440 V 3 phases 30 to 50 kW at 480 to 500 V 3 phases | 230 V AC standard | - | - | - | - | - | - |
| LC1D95Q7 | Contactor | LC1D | 1.2 Mcycles 95 A AC-3 1.3 Mcycles 125 A AC-1 | 4 Mcycles | 85 mm | 127 mm | 130 mm | 1.61 kg | IP20 front face conforming to IEC 60529 | 3 | EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 | -60 to 80 ℃ | IECEE CB Scheme UL CSA CCC EAC LROS (Lloyds register of shipping) RINA BV DNV-GL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0...3000 m | REACH Declaration | 18 months | AC-3 AC-4 AC-1 | 380 V AC 50/60 Hz | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 9 N.m - on connector - with screwdriver flat O 6 to O 8 mm Power circuit: 9 N.m - on connector hexagonal screw head 4 mm | TeSys | Power circuit: 1000 V AC 25...400 Hz | Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified | 10 A (at 60 ℃) for signalling circuit 125 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2flexible without cable end Power circuit: connector 1 cable(s) 4 to 50 mm2flexible with cable end Power circuit: connector 2 cable(s) 4 to 16 mm2flexible with cable end Power circuit: connector 1 cable(s) 4 to 50 mm2solid without cable end Power circuit: connector 2 cable(s) 4 to 25 mm2solid without cable end | 3P | 3600 cyc/h 60 ℃ | 8 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 95 A (at <60 ℃) at <= 440 V AC-3 for power circuit 125 A (at <60 ℃) at <= 690 V AC-1 for power circuit | Rail Plate | 1100 A at 440 V AC for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 | 1100 A 40 ℃ - 1 s for power circuit 800 A 40 ℃ - 10 s for power circuit 400 A 40 ℃ - 1 min for power circuit 135 A 40 ℃ - 10 min for power circuit 140 A - 100 ms for signalling circuit 120 A - 500 ms for signalling circuit 100 A - 1 s for signalling circuit | Resistive load Motor control | 3 NO | AC at 50/60 Hz | 1100 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | 12.5 W AC-1 7.2 W AC-3 | 20...35 ms closing 6...20 ms opening | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor open: 8 Gn for 11 ms Vibrations contactor closed: 3 Gn, 5...300 Hz Shocks contactor closed: 10 Gn for 11 ms | B10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M11 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 245 VA 60 Hz cos phi 0.75 (at 20 ℃) 245 VA 50 Hz cos phi 0.75 (at 20 ℃) | 26 VA 60 Hz cos phi 0.3 (at 20 ℃) 26 VA 50 Hz cos phi 0.3 (at 20 ℃) | 6 to 10 W at 50/60 Hz | Yes | Yes | - | 25 kW at 220...230 V AC 50 Hz (AC-3) 45 kW at 380...400 V AC 50 Hz (AC-3) 45 kW at 415...440 V AC 50 Hz (AC-3) 55 kW at 500 V AC 50 Hz (AC-3) 45 kW at 660...690 V AC 50 Hz (AC-3) 45 kW at 1000 V AC 50 Hz (AC-3) | 7.5 hp at 115 V AC 60 Hz for 1 phase motors 15 hp at 230/240 V AC 60 Hz for 1 phase motors 25 hp at 200/208 V AC 60 Hz for 3 phases motors 30 hp at 230/240 V AC 60 Hz for 3 phases motors 60 hp at 460/480 V AC 60 Hz for 3 phases motors 60 hp at 575/600 V AC 60 Hz for 3 phases motors | - | - | - | - | - | - | - | - | - |
| LC1DT25E7 | Contactor | LC1D | 0.8 Mcycles 25 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.365 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | CCC BV CSA DNV LROS (Lloyds register of shipping) UL RINA GOST GL | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 48 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 25 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 250 A at 440 V for power circuit conforming to IEC 60947 | 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load | 4 NO | AC at 50/60 Hz | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 1.56 W AC-1 | 4...19 ms opening 12...22 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M6 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | - | - | - | - | - | - | - | - | - | - | - |
| LC1DT25F7 | Contactor | LC1D | 0.8 Mcycles 25 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.365 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GL DNV UL CCC GOST CSA RINA BV LROS (Lloyds register of shipping) | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 110 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 25 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 250 A at 440 V for power circuit conforming to IEC 60947 | 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load | 4 NO | AC at 50/60 Hz | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 1.56 W AC-1 | 4...19 ms opening 12...22 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | LC1D | M6 | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | - | - | - | - | - | - | - | - | - | - | - |
| LC1DT25M7 | Contactor | LC1D | 0.8 Mcycles 25 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 85 mm | 92 mm | 0.365 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | GOST DNV LROS (Lloyds register of shipping) CSA UL RINA BV GL CCC | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 220 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 25 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 25 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Plate Rail | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 250 A at 440 V for power circuit conforming to IEC 60947 | 30 A 40 ℃ - 10 min for power circuit 61 A 40 ℃ - 1 min for power circuit 105 A 40 ℃ - 10 s for power circuit 210 A 40 ℃ - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load | 4 NO | AC at 50/60 Hz | 250 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | 1.56 W AC-1 | 4...19 ms opening 12...22 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | - | - | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | - | - | - | - | - | - | - | - | -5 to 60 ℃ | Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 ℃) Operational: 0.8...1.1 Uc AC 50 Hz (at 60 ℃) Operational: 0.85...1.1 Uc AC 60 Hz (at 60 ℃) | -40 to 70 ℃ at Uc |
| LC1DT40FE7 | Contactor | LC1D | 1.4 Mcycles 40 A AC-1 at Ue <= 440 V | 15 Mcycles | 45 mm | 91 mm | 99 mm | 0.425 kg | IP20 front face conforming to IEC 60529 | 3 | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | -60 to 80 ℃ | UL CSA RINA LROS (Lloyds register of shipping) GL BV DNV GOST CCC | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 3000 m without derating | REACH Declaration | 18 months | AC-1 | 115 V AC 50/60 Hz | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 1.7 N.m - on connector - with screwdriver flat O 6 mm Power circuit: 1.7 N.m - on connector - with screwdriver Philips No 2 | TeSys | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 | 10 A (at 60 ℃) for signalling circuit 40 A (at 60 ℃) for power circuit | III | Control circuit: screw clamp terminals 2 cable(s) 1 to 2.5 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1 to 4 mm2solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1 to 4 mm2solid without cable end Power circuit: connector 1 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: connector 2 cable(s) 2.5 to 10 mm2flexible without cable end Power circuit: connector 1 cable(s) 2.5 to 10 mm2flexible with cable end Power circuit: connector 2 cable(s) 2.5 to 10 mm2flexible with cable end Power circuit: connector 1 cable(s) 2.5 to 16 mm2solid without cable end Power circuit: connector 2 cable(s) 2.5 to 16 mm2solid without cable end | 4P | 3600 cyc/h 60 ℃ | 6 kV conforming to IEC 60947 | TH conforming to IEC 60068-2-30 | TeSys D | V1 conforming to UL 94 | 40 A (at <60 ℃) at <= 440 V AC AC-1 for power circuit | Rail Plate | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 450 A at 440 V for power circuit conforming to IEC 60947 | 50 A 40 ℃ - 10 min for power circuit 120 A 40 ℃ - 1 min for power circuit 240 A 40 ℃ - 10 s for power circuit 380 A 40 ℃ - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit | Resistive load | 4 NO | AC at 50/60 Hz | 450 A at 440 V for power circuit conforming to IEC 60947 | 10 A gG for signalling circuit conforming to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit 40 A gG at <= 690 V coordination type 2 for power circuit | 2 mOhm - Ith 40 A 50 Hz for power circuit | 3.2 W AC-1 | 4...19 ms opening 12...22 ms closing | 850 ℃ conforming to IEC 60695-2-1 | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 8 Gn for 11 ms | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | With | Without built-in suppressor module | - | - | 5 mA for signalling circuit | 1 NO + 1 NC | 17 V for signalling circuit | > 10 MOhm for signalling circuit | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 | 25...400 Hz | 70 VA 60 Hz cos phi 0.75 (at 20 ℃) 70 VA 50 Hz cos phi 0.75 (at 20 ℃) | 7.5 VA 60 Hz cos phi 0.3 (at 20 ℃) 7 VA 50 Hz cos phi 0.3 (at 20 ℃) | 2 to 3 W at 50/60 Hz | Yes | Yes | End of Life Information | - | - | - | - | - | - | - | - | -5 to 60 ℃ | Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 ℃) Operational: 0.8...1.1 Uc AC 50 Hz (at 60 ℃) Operational: 0.85...1.1 Uc AC 60 Hz (at 60 ℃) | -40 to 70 ℃ at Uc |