Motor Circuit Breaker TeSys GV3

Caution
Product Description
- Magnetic motor circuit breakers TeSys GV3 series from Schneider electric. - TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for 3-phase motor applications 11kW at 400V. - New modern look & feel of all machines. - Easier to install and operate with multi-standard screws. - Safe and long-lasting power connection with EverLink terminals. - Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh). - Mounting with 35 mm symmetrical DIN rail by clipped, mounting with panel by screwed (with 3 x M4 screws).
| Product Code | Device short name | Fixing mode | Electrical durability | Mechanical durability | Width | Height | Depth | Net weight | IP degree of protection | Standards | Ambient air temperature for operation | Ambient air temperature for storage | Product certifications | Sustainable offer status | EU RoHS Directive | Mercury free | RoHS exemption information | China RoHS Regulation | Environmental Disclosure | WEEE | Operating altitude | REACH Regulation | Warranty | Motor power kW | Utilisation category | Network frequency | Tightening torque | Operating position | Range | [Ue] rated operational voltage | [Ui] rated insulation voltage | IK degree of protection | Connections - terminals | Poles description | Maximum operating rate | [Uimp] rated impulse withstand voltage | Protective treatment | Product name | Breaking capacity | Device application | Control type | Fire resistance | Mechanical robustness | Network type | [Ics] rated service short-circuit breaking capacity | Trip unit technology | Magnetic tripping current | Suitability for isolation |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| GV3L25 | GV3L | 35 mm symmetrical DIN rail: clipped Panel: screwed (with 3 x M4 screws) | 50000 cycles for AC-3 at 415 V | 50000 cycles | 55 mm | 132 mm | 136 mm | 0.96 kg | IP20 conforming to IEC 60529 | EN/IEC 60947-2 EN/IEC 60947-4-1 CSA C22.2 No 60947-4-1 UL 60947-4-1 | -20 to 60 °C | -40 to 80 °C | IECEE CB Scheme UL CSA CCC EAC ABS LROS (Lloyds register of shipping) DNV-GL BV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0...3000 m | REACH Declaration | 18 months | 11 kW at 400/415 V AC 50/60 Hz15 kW at 500 V AC 50/60 Hz 18.5 kW at 690 V AC 50/60 Hz | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 | 50/60 Hz | 5 N.m on EverLink BTR screw connectors for cable 25 mm2 8 N.m on EverLink BTR screw connectors for cable 35 mm2 | Any position | TeSys | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | IK09 | EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2 solid EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2 solid EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2 flexible without cable end EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2 flexible without cable end EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2 flexible with cable end EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2 flexible with cable end | 3P | 25 cyc/h | 6 kV IEC 60947-2 | TH | TeSys GV3 | 100 kA Icu at 230/240 V AC 50/60 Hz 100 kA Icu at 400/415 V AC 50/60 Hz 50 kA Icu at 440 V AC 50/60 Hz 12 kA Icu at 500 V AC 50/60 Hz 6 kA Icu at 690 V AC 50/60 Hz | Motor | Rotary knob | 960 °C conforming to IEC 60695-2-1 | Shocks: 15 Gn for 11 ms closed conforming to IEC 60068-2-27 Shocks: 30 Gn for 11 ms opened conforming to IEC 60068-2-27 Vibrations: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 | AC | 100 % at 230/240 V AC 50/60 Hz 100 % at 400/415 V AC 50/60 Hz 100 % at 440 V AC 50/60 Hz 50 % at 500 V AC 50/60 Hz 50 % at 690 V AC 50/60 Hz | Magnetic | 350 A | Yes conforming to IEC 60947-1 |
| GV3L32 | GV3L | 35 mm symmetrical DIN rail: clipped Panel: screwed (with 3 x M4 screws) | 50000 cycles for AC-3 at 415 V | 50000 cycles | 55 mm | 132 mm | 136 mm | 0.96 kg | IP20 conforming to IEC 60529 | EN/IEC 60947-2 EN/IEC 60947-4-1 CSA C22.2 No 60947-4-1 UL 60947-4-1 | -20 to 60 °C | -40 to 80 °C | IECEE CB Scheme UL CSA CCC EAC ABS LROS (Lloyds register of shipping) DNV-GL BV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0...3000 m | REACH Declaration | 18 months | 15 kW at 400/415 V AC 50/60 Hz 18.5 kW at 500 V AC 50/60 Hz 22 kW at 690 V AC 50/60 Hz | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 | 50/60 Hz | 5 N.m on EverLink BTR screw connectors for cable 25 mm2 8 N.m on EverLink BTR screw connectors for cable 35 mm2 | Any position | TeSys | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | IK09 | EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2 solid EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2 solid EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2 flexible without cable end EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2 flexible without cable end EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2 flexible with cable end EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2 flexible with cable end | 3P | 25 cyc/h | IEC 60947-2 6 kV | TH | TeSys GV3 | 100 kA Icu at 230/240 V AC 50/60 Hz 100 kA Icu at 400/415 V AC 50/60 Hz 50 kA Icu at 440 V AC 50/60 Hz 12 kA Icu at 500 V AC 50/60 Hz 6 kA Icu at 690 V AC 50/60 Hz | Motor | Rotary knob | 960 °C conforming to IEC 60695-2-1 | Shocks: 15 Gn for 11 ms closed conforming to IEC 60068-2-27 Shocks: 30 Gn for 11 ms opened conforming to IEC 60068-2-27 Vibrations: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 | AC | 100 % at 230/240 V AC 50/60 Hz 100 % at 400/415 V AC 50/60 Hz 100 % at 440 V AC 50/60 Hz 50 % at 500 V AC 50/60 Hz 50 % at 690 V AC 50/60 Hz | Magnetic | 448 A | Yes conforming to IEC 60947-1 |
| GV3L65 | GV3L | 35 mm symmetrical DIN rail: clipped Panel: screwed (with 3 x M4 screws) | 50000 cycles for AC-3 at 415 V | 50000 cycles | 55 mm | 132 mm | 136 mm | 0.96 kg | IP20 conforming to IEC 60529 | EN/IEC 60947-2 EN/IEC 60947-4-1 CSA C22.2 No 60947-4-1 UL 60947-4-1 | -20 to 60 °C | -40 to 80 °C | IECEE CB Scheme UL CSA CCC EAC ABS LROS (Lloyds register of shipping) DNV-GL BV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0...3000 m | REACH Declaration | 18 months | 55 kW at 690 V AC 50/60 Hz 30 kW at 400/415 V AC 50/60 Hz 37 kW at 500 V AC 50/60 Hz | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 | 50/60 Hz | 5 N.m on EverLink BTR screw connectors for cable 25 mm2 8 N.m on EverLink BTR screw connectors for cable 35 mm2 | Any position | TeSys | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | IK09 | EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2 solid EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2 solid EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2 flexible without cable end EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2 flexible without cable end EverLink BTR screw connectors 1 cable(s) 1 to 35 mm2 flexible with cable end EverLink BTR screw connectors 2 cable(s) 1 to 25 mm2 flexible with cable end | 3P | 25 cyc/h | IEC 60947-2 6 kV | TH | TeSys GV3 | 100 kA Icu at 230/240 V AC 50/60 Hz 50 kA Icu at 440 V AC 50/60 Hz 12 kA Icu at 500 V AC 50/60 Hz 6 kA Icu at 690 V AC 50/60 Hz 50 kA Icu at 400/415 V AC 50/60 Hz | Motor | Rotary knob | 960 °C conforming to IEC 60695-2-1 | Shocks: 15 Gn for 11 ms closed conforming to IEC 60068-2-27 Shocks: 30 Gn for 11 ms opened conforming to IEC 60068-2-27 Vibrations: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 | AC | 100 % at 230/240 V AC 50/60 Hz 100 % at 400/415 V AC 50/60 Hz 100 % at 440 V AC 50/60 Hz 50 % at 500 V AC 50/60 Hz 50 % at 690 V AC 50/60 Hz | Magnetic | 910 A | Yes conforming to IEC 60947-1 |