Motor Circuit Breaker TeSys GV2 with rotary knob

Brand :
Schneider Electric

Caution

    Product Description

    - Magnetic motor circuit breakers TeSys GV2 series from Schneider electric. - TeSys GV motor circuit breaker, 3 poles (3P), 10A/690V, for 3-phase motor applications 3-4kW at 400V. - New modern look & feel of all machines. - Easier to install and operate with multi-standard screws. - Safe and long-lasting power connection with EverLink terminals. - Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh). - Mounting with 35 mm symmetrical DIN rail by clipped, mounting with panel by screwed (with 3 x M4 screws).

    Product CodeDevice short nameFixing modeElectrical durabilityMechanical durabilityWidthHeightDepthNet weightIP degree of protectionStandardsAmbient air temperature for operationAmbient air temperature for storageProduct certificationsSustainable offer statusEU RoHS DirectiveMercury freeRoHS exemption informationChina RoHS RegulationEnvironmental DisclosureWEEEOperating altitudeREACH RegulationWarrantyMotor power kWUtilisation categoryNetwork frequencyTightening torqueOperating positionRange[Ue] rated operational voltage[Ui] rated insulation voltageIK degree of protectionConnections - terminalsPoles descriptionMaximum operating rate[Uimp] rated impulse withstand voltageProtective treatmentProduct nameBreaking capacityDevice applicationControl typePower dissipation per poleFire resistanceMechanical robustnessNetwork type[Ics] rated service short-circuit breaking capacityTrip unit technologyMagnetic tripping currentRated dutySuitability for isolation
    GV2L03GV2L35 mm symmetrical DIN rail: clipped
    Panel: screwed (with 2 x M4 screws)
    100000 cycles 
    for AC-3 at 415 V
    100000 cycles45 mm89
    mm
    97 mm0.33 kgIP20 conforming to IEC 60529EN/IEC 
    60947-2
    EN/IEC 
    60947-4-1
    CSA C22.2 No 
    60947-4-1
    UL 60947-4-1
    -20 to 60 °C-40 to 80 °CIECEE CB Scheme
    UL
    CSA
    CCC
    EAC
    RINA
    LROS (Lloyds register of shipping)
    DNV-GL
    BV
    Green Premium productCompliant  EU RoHS DeclarationYesYesChina RoHS declarationProduct Environmental ProfileThe product must be disposed on European Union markets following specific 
    waste collection and never end up in rubbish bins
    0...2000 mREACH Declaration18 months0.09 kW 
    at 400/415 V AC 50/60 Hz
    Category A conforming to 
    IEC 60947-2
    AC-3 conforming to 
    IEC 60947-4-1
    50/60 Hz conforming to 
    IEC 60947-2
    1.7 N.m 
    on screw clamp terminals
    Any positionTeSys690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    IK04Screw clamp terminals 2 cable(s) 
    1 to 6 mm2 solid
    Screw clamp terminals 2 cable(s) 
    1.5 to 6 mm2 
    flexible without cable end
    Screw clamp terminals 2 cable(s) 
    1 to 4 mm2 
    flexible with cable end
    3P40 cyc/hIEC 60947-2 6 kVTHTeSys GV2100 kA Icu 
    at 230/240 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA Icu 
    at 400/415 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA Icu 
    at 440 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA Icu 
    at 500 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA Icu 
    at 690 V AC 50/60 Hz 
    conforming to IEC 60947-2
    MotorRotary knob1.8 W960 °C conforming to 
    IEC 60695-2-1
    Vibrations: 5 Gn, 5...150 Hz conforming to 
    IEC 60068-2-6
    Shocks: 30 Gn conforming to 
    IEC 60068-2-27
    AC100 % 
    at 690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % at 500 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 230/240 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 440 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 400/415 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    Magnetic5 AContinuous conforming to 
    IEC 60947-4-1
    Yes conforming to 
    IEC 60947-1
    GV2L05GV2L35 mm symmetrical DIN rail: clipped
    Panel: screwed (with 2 x M4 screws)
    100000 cycles 
    for AC-3 at 415 V
    100000 cycles45 mm89
    mm
    97 mm0.33 kgIP20 conforming to IEC 60529EN/IEC 
    60947-2
    EN/IEC 
    60947-4-1
    CSA C22.2 No 
    60947-4-1
    UL 60947-4-1
    -20 to 60 °C-40 to 80 °CIECEE CB Scheme
    UL
    CSA
    CCC
    EAC
    RINA
    LROS (Lloyds register of shipping)
    DNV-GL
    BV
    Green Premium productCompliant  EU RoHS DeclarationYesYesChina RoHS declarationProduct Environmental ProfileThe product must be disposed on European Union markets following specific 
    waste collection and never end up in rubbish bins
    0...2000 mREACH Declaration18 months0.25 kW 
    at 400/415 V AC 
    50/60 Hz
    0.37 kW 
    at 400/415 V AC 
    50/60 Hz
    0.37 kW 
    at 500 V AC 
    50/60 Hz
    0.55 kW 
    at 690 V AC 
    50/60 Hz
    0.75 kW 
    at 690 V AC 
    50/60 Hz
    Category A conforming to 
    IEC 60947-2
    AC-3 conforming to 
    IEC 60947-4-1
    50/60 Hz conforming to 
    IEC 60947-2
    1.7 N.m 
    on screw clamp terminals
    Any positionTeSys690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    IK04Screw clamp terminals 2 cable(s) 
    1 to 6 mm2 solid
    Screw clamp terminals 2 cable(s) 
    1.5 to 6 mm2 
    flexible without cable end
    Screw clamp terminals 2 cable(s) 
    1 to 4 mm2 
    flexible with cable end
    3P40 cyc/hIEC 60947-2 6 kVTHTeSys GV2100 kA Icu at 
    230/240 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA Icu at 
    400/415 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA Icu 
    at 440 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA Icu 
    at 500 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA Icu 
    at 690 V AC 50/60 Hz 
    conforming to IEC 60947-2
    MotorRotary knob1.8 W960 °C conforming to 
    IEC 60695-2-1
    Shocks: 30 Gn conforming to IEC 60068-2-27
    Vibrations: 5 Gn, 5...150 Hz conforming to 
    IEC 60068-2-6
    AC100 % 
    at 690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 500 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 230/240 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 440 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 400/415 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    Magnetic13 AContinuous conforming to 
    IEC 60947-4-1
    Yes conforming to 
    IEC 60947-1
    GV2L06GV2L35 mm symmetrical DIN rail: clipped
    Panel: screwed (with 2 x M4 screws)
    100000 cycles 
    for AC-3 at 415 V
    100000 cycles45 mm89
    mm
    97 mm0.33 kgIP20 conforming to IEC 60529EN/IEC 
    60947-2
    EN/IEC 
    60947-4-1
    CSA C22.2 No 
    60947-4-1
    UL 60947-4-1
    -20 to 60 °C-40 to 80 °CIECEE CB Scheme
    UL
    CSA
    CCC
    EAC
    RINA
    LROS (Lloyds register of shipping)
    DNV-GL
    BV
    Green Premium productCompliant  EU RoHS DeclarationYesYesChina RoHS declarationProduct Environmental ProfileThe product must be disposed on European Union markets following specific 
    waste collection and never end up in rubbish bins
    0...2000 mREACH Declaration18 months0.55 kW 
    at 400/415 V AC 
    50/60 Hz
    0.55 kW at 500 V AC 
    50/60 Hz
    0.75 kW at 500 V AC 
    50/60 Hz
    1.1 kW 
    at 690 V AC 
    50/60 Hz
    Category A conforming to 
    IEC 60947-2
    AC-3 conforming to 
    IEC 60947-4-1
    50/60 Hz conforming to 
    IEC 60947-2
    1.7 N.m 
    on screw clamp terminals
    Any positionTeSys690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    IK04Screw clamp terminals 2 cable(s) 
    1 to 6 mm2 solid
    Screw clamp terminals 2 cable(s) 
    1.5 to 6 mm2 
    flexible without cable end
    Screw clamp terminals 2 cable(s) 
    1 to 4 mm2 
    flexible with cable end
    3P40 cyc/hIEC 60947-2 6 kVTHTeSys GV2100 kA Icu at 230/240 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA Icu at 400/415 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA Icu at 440 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA Icu at 500 V AC 50/60 Hz 
    conforming to IEC 60947-2
    4 kA Icu at 690 V AC 50/60 Hz 
    conforming to IEC 60947-2
    MotorRotary knob1.8 W960 °C conforming to 
    IEC 60695-2-1
    Shocks: 30 Gn conforming to 
    IEC 60068-2-27
    Vibrations: 5 Gn, 5...150 Hz conforming to 
    IEC 60068-2-6
    AC100 % 
    at 690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 500 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 230/240 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 440 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 400/415 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    Magnetic22.5 AContinuous conforming to 
    IEC 60947-4-1
    Yes conforming to 
    IEC 60947-1
    GV2L07GV2L35 mm symmetrical DIN rail: clipped
    Panel: screwed (with 2 x M4 screws)
    100000 cycles 
    for AC-3 at 415 V
    100000 cycles45 mm89
    mm
    97 mm0.33 kgIP20 conforming to IEC 60529EN/IEC 
    60947-2
    EN/IEC 
    60947-4-1
    CSA C22.2 No 
    60947-4-1
    UL 60947-4-1
    -20 to 60 °C-40 to 80 °CIECEE CB Scheme
    UL
    CSA
    CCC
    EAC
    RINA
    LROS (Lloyds register of shipping)
    DNV-GL
    BV
    Green Premium productCompliant  EU RoHS DeclarationYesYesChina RoHS declarationProduct Environmental ProfileThe product must be disposed on European Union markets following specific 
    waste collection and never end up in rubbish bins
    0...2000 mREACH Declaration18 months0.75 kW 
    at 400/415 V AC 
    50/60 Hz
    1.1 kW 
    at 500 V AC 
    50/60 Hz
    1.5 kW 
    at 690 V AC 
    50/60 Hz
    Category A conforming to 
    IEC 60947-2
    AC-3 conforming to 
    IEC 60947-4-1
    50/60 Hz conforming to 
    IEC 60947-2
    1.7 N.m 
    on screw clamp terminals
    Any positionTeSys690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    IK04Screw clamp terminals 2 cable(s) 
    1 to 6 mm2 solid
    Screw clamp terminals 2 cable(s) 
    1.5 to 6 mm2 
    flexible without cable end
    Screw clamp terminals 2 cable(s) 
    1 to 4 mm2 
    flexible with cable end
    3P40 cyc/h6 kV IEC 60947-2THTeSys GV2100 kA Icu 
    at 230/240 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA Icu 
    at 400/415 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA Icu 
    at 440 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA Icu 
    at 500 V AC 50/60 Hz 
    conforming to IEC 60947-2
    4 kA Icu 
    at 690 V AC 50/60 Hz 
    conforming to IEC 60947-2
    MotorRotary knob1.8 W960 °C conforming to 
    IEC 60695-2-1
    Shocks: 30 Gn conforming to 
    IEC 60068-2-27
    Vibrations: 5 Gn, 5...150 Hz conforming to 
    IEC 60068-2-6
    AC100 % 
    at 690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 500 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 230/240 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 440 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 400/415 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    Magnetic33.5 AContinuous conforming to 
    IEC 60947-4-1
    Yes conforming to 
    IEC 60947-1
    GV2L08GV2L35 mm symmetrical DIN rail: clipped
    Panel: screwed (with 2 x M4 screws)
    100000 cycles 
    for AC-3 at 415 V
    100000 cycles45 mm89
    mm
    97 mm0.33 kgIP20 conforming to IEC 60529EN/IEC 
    60947-2
    EN/IEC 
    60947-4-1
    CSA C22.2 No 
    60947-4-1
    UL 60947-4-1
    -20 to 60 °C-40 to 80 °CIECEE CB Scheme
    UL
    CSA
    CCC
    EAC
    RINA
    LROS (Lloyds register of shipping)
    DNV-GL
    BV
    Green Premium productCompliant  EU RoHS DeclarationYesYesChina RoHS declarationProduct Environmental ProfileThe product must be disposed on European Union markets following specific 
    waste collection and never end up in rubbish bins
    0...2000 mREACH Declaration18 months1.1 kW 
    at 400/415 V AC 
    50/60 Hz
    1.5 kW 
    at 400/415 V AC 
    50/60 Hz
    1.5 kW 
    at 500 V AC 
    50/60 Hz
    3 kW 
    at 690 V AC 
    50/60 Hz
    Category A conforming to 
    IEC 60947-2
    AC-3 conforming to 
    IEC 60947-4-1
    50/60 Hz conforming to 
    IEC 60947-2
    1.7 N.m 
    on screw clamp terminals
    Any positionTeSys690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    IK04Screw clamp terminals 2 cable(s) 
    1 to 6 mm2 solid
    Screw clamp terminals 2 cable(s) 
    1.5 to 6 mm2 
    flexible without cable end
    Screw clamp terminals 2 cable(s) 
    1 to 4 mm2 
    flexible with cable end
    3P40 cyc/hIEC 60947-2 6 kVTHTeSys GV2100 kA Icu 
    at 230/240 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA Icu 
    at 400/415 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA Icu 
    at 440 V AC 50/60 Hz 
    conforming to IEC 60947-2
    100 kA 
    Icu at 500 V AC 50/60 Hz 
    conforming to IEC 60947-2
    4 kA Icu 
    at 690 V AC 50/60 Hz 
    conforming to IEC 60947-2
    MotorRotary knob1.8 W960 °C conforming to 
    IEC 60695-2-1
    Shocks: 30 Gn conforming to 
    IEC 60068-2-27
    Vibrations: 5 Gn, 5...150 Hz conforming to 
    IEC 60068-2-6
    AC100 % 
    at 690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 500 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 230/240 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 440 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 400/415 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    Magnetic51 AContinuous conforming to 
    IEC 60947-4-1
    Yes conforming to 
    IEC 60947-1
    GV2L16GV2L35 mm symmetrical DIN rail: clipped
    Panel: screwed (with 2 x M4 screws)
    100000 cycles 
    for AC-3 at 415 V
    100000 cycles45 mm89
    mm
    97 mm0.33 kgIP20 conforming to IEC 60529EN/IEC 
    60947-2
    EN/IEC 
    60947-4-1
    CSA C22.2 No 
    60947-4-1
    UL 60947-4-1
    -20 to 60 °C-40 to 80 °CIECEE CB Scheme
    UL
    CSA
    CCC
    EAC
    RINA
    LROS (Lloyds register of shipping)
    DNV-GL
    BV
    Green Premium productCompliant  EU RoHS DeclarationYesYesChina RoHS declarationProduct Environmental ProfileThe product must be disposed on European Union markets following specific 
    waste collection and never end up in rubbish bins
    0...2000 mREACH Declaration18 months5.5 kW 
    at 400/415 V AC 
    50/60 Hz
    7.5 kW 
    at 500 V AC 
    50/60 Hz
    9 kW 
    at 690 V AC 
    50/60 Hz
    11 kW 
    at 690 V AC 
    50/60 Hz
    Category A conforming to 
    IEC 60947-2
    AC-3 conforming to 
    IEC 60947-4-1
    50/60 Hz conforming to 
    IEC 60947-2
    1.7 N.m 
    on screw clamp terminals
    Any positionTeSys690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    IK04Screw clamp terminals 2 cable(s) 
    1 to 6 mm2 solid
    Screw clamp terminals 2 cable(s) 
    1.5 to 6 mm2 
    flexible without cable end
    Screw clamp terminals 2 cable(s) 
    1 to 4 mm2 
    flexible with cable end
    3P40 cyc/hIEC 60947-2 6 kVTHTeSys GV2100 kA Icu 
    at 230/240 V AC 50/60 Hz 
    conforming to IEC 60947-2
    4 kA Icu 
    at 690 V AC 50/60 Hz 
    conforming to IEC 60947-2
    10 kA Icu
     at 500 V AC 50/60 Hz 
    conforming to IEC 60947-2
    20 kA Icu 
    at 440 V AC 50/60 Hz 
    conforming to IEC 60947-2
    50 kA Icu 
    at 400/415 V AC 50/60 Hz 
    conforming to IEC 60947-2
    MotorRotary knob1.8 W960 °C conforming to 
    IEC 60695-2-1
    Shocks: 30 Gn conforming to 
    IEC 60068-2-27
    Vibrations: 5 Gn, 5...150 Hz conforming to 
    IEC 60068-2-6
    AC100 % 
    at 690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 230/240 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    75 % 
    at 440 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    75 % 
    at 500 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    50 % 
    at 400/415 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    Magnetic170 AContinuous conforming to 
    IEC 60947-4-1
    Yes conforming to 
    IEC 60947-1
    GV2L20GV2L35 mm symmetrical DIN rail: clipped
    Panel: screwed (with 2 x M4 screws)
    100000 cycles 
    for AC-3 at 415 V
    100000 cycles45 mm89
    mm
    97 mm0.33 kgIP20 conforming to IEC 60529EN/IEC 
    60947-2
    EN/IEC 
    60947-4-1
    CSA C22.2 No 
    60947-4-1
    UL 60947-4-1
    -20 to 60 °C-40 to 80 °CIECEE CB Scheme
    UL
    CSA
    CCC
    EAC
    RINA
    LROS (Lloyds register of shipping)
    DNV-GL
    BV
    Green Premium productCompliant  EU RoHS DeclarationYesYesChina RoHS declarationProduct Environmental ProfileThe product must be disposed on European Union markets following specific 
    waste collection and never end up in rubbish bins
    0...2000 mREACH Declaration18 months7.5 kW 
    at 400/415 V AC 
    50/60 Hz
    9 kW 
    at 500 V AC 
    50/60 Hz
    15 kW 
    at 690 V AC 
    50/60 Hz
    Category A conforming to 
    IEC 60947-2
    AC-3 conforming to 
    IEC 60947-4-1
    50/60 Hz conforming to 
    IEC 60947-2
    1.7 N.m 
    on screw clamp terminals
    Any positionTeSys690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    IK04Screw clamp terminals 2 cable(s) 
    1 to 6 mm2 solid
    Screw clamp terminals 2 cable(s) 
    1.5 to 6 mm2 
    flexible without cable end
    Screw clamp terminals 2 cable(s) 
    1 to 4 mm2 
    flexible with cable end
    3P40 cyc/hIEC 60947-2 6 kVTHTeSys GV2100 kA Icu 
    at 230/240 V AC 50/60 Hz 
    conforming to IEC 60947-2
    4 kA Icu 
    at 690 V AC 50/60 Hz 
    conforming to IEC 60947-2
    10 kA Icu 
    at 500 V AC 50/60 Hz 
    conforming to IEC 60947-2
    20 kA Icu 
    at 440 V AC 50/60 Hz 
    conforming to IEC 60947-2
    50 kA Icu at 
    400/415 V AC 50/60 Hz 
    conforming to IEC 60947-2
    MotorRotary knob1.8 W960 °C conforming to 
    IEC 60695-2-1
    Shocks: 30 Gn conforming to 
    IEC 60068-2-27
    Vibrations: 5 Gn, 5...150 Hz conforming to 
    IEC 60068-2-6
    AC100 % 
    at 690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 230/240 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    75 % 
    at 440 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    75 % 
    at 500 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    50 % 
    at 400/415 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    Magnetic223 AContinuous conforming to 
    IEC 60947-4-1
    Yes conforming to 
    IEC 60947-1
    GV2L22GV2L35 mm symmetrical DIN rail: clipped
    Panel: screwed (with 2 x M4 screws)
    100000 cycles 
    for AC-3 at 415 V
    100000 cycles45 mm89
    mm
    97 mm0.33 kgIP20 conforming to IEC 60529EN/IEC 
    60947-2
    EN/IEC 
    60947-4-1
    CSA C22.2 No 
    60947-4-1
    UL 60947-4-1
    -20 to 60 °C-40 to 80 °CIECEE CB Scheme
    UL
    CSA
    CCC
    EAC
    RINA
    LROS (Lloyds register of shipping)
    DNV-GL
    BV
    Green Premium productCompliant  EU RoHS DeclarationYesYesChina RoHS declarationProduct Environmental ProfileThe product must be disposed on European Union markets following specific 
    waste collection and never end up in rubbish bins
    0...2000 mREACH Declaration18 months9 kW 
    at 400/415 V AC 
    50/60 Hz
    11 kW 
    at 400/415 V AC 
    50/60 Hz
    11 kW 
    at 500 V AC 
    50/60 Hz
    15 kW 
    at 500 V AC 
    50/60 Hz
    18.5 kW 
    at 690 V AC 
    50/60 Hz
    Category A conforming to 
    IEC 60947-2
    AC-3 conforming to 
    IEC 60947-4-1
    50/60 Hz conforming to 
    IEC 60947-2
    1.7 N.m 
    on screw clamp terminals
    Any positionTeSys690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    IK04Screw clamp terminals 2 cable(s) 
    1 to 6 mm2 solid
    Screw clamp terminals 2 cable(s) 
    1.5 to 6 mm2 flexible without cable end
    Screw clamp terminals 2 cable(s) 
    1 to 4 mm2 
    flexible with cable end
    3P40 cyc/hIEC 60947-2 6 kVTHTeSys GV24 kA Icu 
    at 690 V AC 50/60 Hz 
    conforming to IEC 60947-2
    10 kA Icu 
    at 500 V AC 50/60 Hz 
    conforming to IEC 60947-2
    20 kA Icu 
    at 440 V AC 50/60 Hz 
    conforming to IEC 60947-2
    50 kA Icu 
    at 400/415 V AC 50/60 Hz 
    conforming to IEC 60947-2
    50 kA Icu 
    at 230/240 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    MotorRotary knob1.8 W960 °C conforming to 
    IEC 60695-2-1
    Shocks: 30 Gn conforming to 
    IEC 60068-2-27
    Vibrations: 5 Gn, 5...150 Hz conforming to 
    IEC 60068-2-6
    AC100 % 
    at 690 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    100 % 
    at 230/240 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    75 % 
    at 440 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    75 % 
    at 500 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    50 % 
    at 400/415 V AC 50/60 Hz 
    conforming to 
    IEC 60947-2
    Magnetic327 AContinuous conforming to 
    IEC 60947-4-1
    Yes conforming to 
    IEC 60947-1
    Viewed Products
    Recently Viewed Products
    My Components
    My Components
    0
    Cart
    Cart
    Economy Series
    MRO Product

    Chat with MISUMI

    Chat service is available for any inquiry to MISUMI

    Service hours

    9:00 - 18:00 (Mon-Sat)

    For out of service hours, you can leave a message to us.
    We will reply to your inquiries on the next business day.
    (except Sundays and public holidays).

    Noted for use

    Chat service is for Corporate customers and limited for Thai language.

    Request for Quotation and Place Order is not available on Chat.

    Start chat