- Magnetic motor circuit breakers TeSys GV2 series from Schneider electric. - TeSys GV motor circuit breaker, 3 poles (3P), 10A/690V, for 3-phase motor applications 3-4kW at 400V. - New modern look & feel of all machines. - Easier to install and operate with multi-standard screws. - Safe and long-lasting power connection with EverLink terminals. - Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh). - Mounting with 35 mm symmetrical DIN rail by clipped, mounting with panel by screwed (with 3 x M4 screws).
Product Code | Device short name | Fixing mode | Electrical durability | Mechanical durability | Width | Height | Depth | Net weight | IP degree of protection | Standards | Ambient air temperature for operation | Ambient air temperature for storage | Product certifications | Sustainable offer status | EU RoHS Directive | Mercury free | RoHS exemption information | China RoHS Regulation | Environmental Disclosure | WEEE | Operating altitude | REACH Regulation | Warranty | Motor power kW | Utilisation category | Network frequency | Tightening torque | Operating position | Range | [Ue] rated operational voltage | [Ui] rated insulation voltage | IK degree of protection | Connections - terminals | Poles description | Maximum operating rate | [Uimp] rated impulse withstand voltage | Protective treatment | Product name | Breaking capacity | Device application | Control type | Power dissipation per pole | Fire resistance | Mechanical robustness | Network type | [Ics] rated service short-circuit breaking capacity | Trip unit technology | Magnetic tripping current | Rated duty | Suitability for isolation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GV2L03 | GV2L | 35 mm symmetrical DIN rail: clipped Panel: screwed (with 2 x M4 screws) | 100000 cycles for AC-3 at 415 V | 100000 cycles | 45 mm | 89 mm | 97 mm | 0.33 kg | IP20 conforming to IEC 60529 | EN/IEC 60947-2 EN/IEC 60947-4-1 CSA C22.2 No 60947-4-1 UL 60947-4-1 | -20 to 60 °C | -40 to 80 °C | IECEE CB Scheme UL CSA CCC EAC RINA LROS (Lloyds register of shipping) DNV-GL BV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0...2000 m | REACH Declaration | 18 months | 0.09 kW at 400/415 V AC 50/60 Hz | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 | 50/60 Hz conforming to IEC 60947-2 | 1.7 N.m on screw clamp terminals | Any position | TeSys | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | IK04 | Screw clamp terminals 2 cable(s) 1 to 6 mm2 solid Screw clamp terminals 2 cable(s) 1.5 to 6 mm2 flexible without cable end Screw clamp terminals 2 cable(s) 1 to 4 mm2 flexible with cable end | 3P | 40 cyc/h | IEC 60947-2 6 kV | TH | TeSys GV2 | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 | Motor | Rotary knob | 1.8 W | 960 °C conforming to IEC 60695-2-1 | Vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6 Shocks: 30 Gn conforming to IEC 60068-2-27 | AC | 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Magnetic | 5 A | Continuous conforming to IEC 60947-4-1 | Yes conforming to IEC 60947-1 |
GV2L05 | GV2L | 35 mm symmetrical DIN rail: clipped Panel: screwed (with 2 x M4 screws) | 100000 cycles for AC-3 at 415 V | 100000 cycles | 45 mm | 89 mm | 97 mm | 0.33 kg | IP20 conforming to IEC 60529 | EN/IEC 60947-2 EN/IEC 60947-4-1 CSA C22.2 No 60947-4-1 UL 60947-4-1 | -20 to 60 °C | -40 to 80 °C | IECEE CB Scheme UL CSA CCC EAC RINA LROS (Lloyds register of shipping) DNV-GL BV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0...2000 m | REACH Declaration | 18 months | 0.25 kW at 400/415 V AC 50/60 Hz 0.37 kW at 400/415 V AC 50/60 Hz 0.37 kW at 500 V AC 50/60 Hz 0.55 kW at 690 V AC 50/60 Hz 0.75 kW at 690 V AC 50/60 Hz | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 | 50/60 Hz conforming to IEC 60947-2 | 1.7 N.m on screw clamp terminals | Any position | TeSys | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | IK04 | Screw clamp terminals 2 cable(s) 1 to 6 mm2 solid Screw clamp terminals 2 cable(s) 1.5 to 6 mm2 flexible without cable end Screw clamp terminals 2 cable(s) 1 to 4 mm2 flexible with cable end | 3P | 40 cyc/h | IEC 60947-2 6 kV | TH | TeSys GV2 | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 | Motor | Rotary knob | 1.8 W | 960 °C conforming to IEC 60695-2-1 | Shocks: 30 Gn conforming to IEC 60068-2-27 Vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6 | AC | 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Magnetic | 13 A | Continuous conforming to IEC 60947-4-1 | Yes conforming to IEC 60947-1 |
GV2L06 | GV2L | 35 mm symmetrical DIN rail: clipped Panel: screwed (with 2 x M4 screws) | 100000 cycles for AC-3 at 415 V | 100000 cycles | 45 mm | 89 mm | 97 mm | 0.33 kg | IP20 conforming to IEC 60529 | EN/IEC 60947-2 EN/IEC 60947-4-1 CSA C22.2 No 60947-4-1 UL 60947-4-1 | -20 to 60 °C | -40 to 80 °C | IECEE CB Scheme UL CSA CCC EAC RINA LROS (Lloyds register of shipping) DNV-GL BV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0...2000 m | REACH Declaration | 18 months | 0.55 kW at 400/415 V AC 50/60 Hz 0.55 kW at 500 V AC 50/60 Hz 0.75 kW at 500 V AC 50/60 Hz 1.1 kW at 690 V AC 50/60 Hz | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 | 50/60 Hz conforming to IEC 60947-2 | 1.7 N.m on screw clamp terminals | Any position | TeSys | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | IK04 | Screw clamp terminals 2 cable(s) 1 to 6 mm2 solid Screw clamp terminals 2 cable(s) 1.5 to 6 mm2 flexible without cable end Screw clamp terminals 2 cable(s) 1 to 4 mm2 flexible with cable end | 3P | 40 cyc/h | IEC 60947-2 6 kV | TH | TeSys GV2 | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 | Motor | Rotary knob | 1.8 W | 960 °C conforming to IEC 60695-2-1 | Shocks: 30 Gn conforming to IEC 60068-2-27 Vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6 | AC | 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Magnetic | 22.5 A | Continuous conforming to IEC 60947-4-1 | Yes conforming to IEC 60947-1 |
GV2L07 | GV2L | 35 mm symmetrical DIN rail: clipped Panel: screwed (with 2 x M4 screws) | 100000 cycles for AC-3 at 415 V | 100000 cycles | 45 mm | 89 mm | 97 mm | 0.33 kg | IP20 conforming to IEC 60529 | EN/IEC 60947-2 EN/IEC 60947-4-1 CSA C22.2 No 60947-4-1 UL 60947-4-1 | -20 to 60 °C | -40 to 80 °C | IECEE CB Scheme UL CSA CCC EAC RINA LROS (Lloyds register of shipping) DNV-GL BV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0...2000 m | REACH Declaration | 18 months | 0.75 kW at 400/415 V AC 50/60 Hz 1.1 kW at 500 V AC 50/60 Hz 1.5 kW at 690 V AC 50/60 Hz | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 | 50/60 Hz conforming to IEC 60947-2 | 1.7 N.m on screw clamp terminals | Any position | TeSys | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | IK04 | Screw clamp terminals 2 cable(s) 1 to 6 mm2 solid Screw clamp terminals 2 cable(s) 1.5 to 6 mm2 flexible without cable end Screw clamp terminals 2 cable(s) 1 to 4 mm2 flexible with cable end | 3P | 40 cyc/h | 6 kV IEC 60947-2 | TH | TeSys GV2 | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 | Motor | Rotary knob | 1.8 W | 960 °C conforming to IEC 60695-2-1 | Shocks: 30 Gn conforming to IEC 60068-2-27 Vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6 | AC | 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Magnetic | 33.5 A | Continuous conforming to IEC 60947-4-1 | Yes conforming to IEC 60947-1 |
GV2L08 | GV2L | 35 mm symmetrical DIN rail: clipped Panel: screwed (with 2 x M4 screws) | 100000 cycles for AC-3 at 415 V | 100000 cycles | 45 mm | 89 mm | 97 mm | 0.33 kg | IP20 conforming to IEC 60529 | EN/IEC 60947-2 EN/IEC 60947-4-1 CSA C22.2 No 60947-4-1 UL 60947-4-1 | -20 to 60 °C | -40 to 80 °C | IECEE CB Scheme UL CSA CCC EAC RINA LROS (Lloyds register of shipping) DNV-GL BV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0...2000 m | REACH Declaration | 18 months | 1.1 kW at 400/415 V AC 50/60 Hz 1.5 kW at 400/415 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 3 kW at 690 V AC 50/60 Hz | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 | 50/60 Hz conforming to IEC 60947-2 | 1.7 N.m on screw clamp terminals | Any position | TeSys | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | IK04 | Screw clamp terminals 2 cable(s) 1 to 6 mm2 solid Screw clamp terminals 2 cable(s) 1.5 to 6 mm2 flexible without cable end Screw clamp terminals 2 cable(s) 1 to 4 mm2 flexible with cable end | 3P | 40 cyc/h | IEC 60947-2 6 kV | TH | TeSys GV2 | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 | Motor | Rotary knob | 1.8 W | 960 °C conforming to IEC 60695-2-1 | Shocks: 30 Gn conforming to IEC 60068-2-27 Vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6 | AC | 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Magnetic | 51 A | Continuous conforming to IEC 60947-4-1 | Yes conforming to IEC 60947-1 |
GV2L16 | GV2L | 35 mm symmetrical DIN rail: clipped Panel: screwed (with 2 x M4 screws) | 100000 cycles for AC-3 at 415 V | 100000 cycles | 45 mm | 89 mm | 97 mm | 0.33 kg | IP20 conforming to IEC 60529 | EN/IEC 60947-2 EN/IEC 60947-4-1 CSA C22.2 No 60947-4-1 UL 60947-4-1 | -20 to 60 °C | -40 to 80 °C | IECEE CB Scheme UL CSA CCC EAC RINA LROS (Lloyds register of shipping) DNV-GL BV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0...2000 m | REACH Declaration | 18 months | 5.5 kW at 400/415 V AC 50/60 Hz 7.5 kW at 500 V AC 50/60 Hz 9 kW at 690 V AC 50/60 Hz 11 kW at 690 V AC 50/60 Hz | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 | 50/60 Hz conforming to IEC 60947-2 | 1.7 N.m on screw clamp terminals | Any position | TeSys | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | IK04 | Screw clamp terminals 2 cable(s) 1 to 6 mm2 solid Screw clamp terminals 2 cable(s) 1.5 to 6 mm2 flexible without cable end Screw clamp terminals 2 cable(s) 1 to 4 mm2 flexible with cable end | 3P | 40 cyc/h | IEC 60947-2 6 kV | TH | TeSys GV2 | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Motor | Rotary knob | 1.8 W | 960 °C conforming to IEC 60695-2-1 | Shocks: 30 Gn conforming to IEC 60068-2-27 Vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6 | AC | 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Magnetic | 170 A | Continuous conforming to IEC 60947-4-1 | Yes conforming to IEC 60947-1 |
GV2L20 | GV2L | 35 mm symmetrical DIN rail: clipped Panel: screwed (with 2 x M4 screws) | 100000 cycles for AC-3 at 415 V | 100000 cycles | 45 mm | 89 mm | 97 mm | 0.33 kg | IP20 conforming to IEC 60529 | EN/IEC 60947-2 EN/IEC 60947-4-1 CSA C22.2 No 60947-4-1 UL 60947-4-1 | -20 to 60 °C | -40 to 80 °C | IECEE CB Scheme UL CSA CCC EAC RINA LROS (Lloyds register of shipping) DNV-GL BV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0...2000 m | REACH Declaration | 18 months | 7.5 kW at 400/415 V AC 50/60 Hz 9 kW at 500 V AC 50/60 Hz 15 kW at 690 V AC 50/60 Hz | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 | 50/60 Hz conforming to IEC 60947-2 | 1.7 N.m on screw clamp terminals | Any position | TeSys | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | IK04 | Screw clamp terminals 2 cable(s) 1 to 6 mm2 solid Screw clamp terminals 2 cable(s) 1.5 to 6 mm2 flexible without cable end Screw clamp terminals 2 cable(s) 1 to 4 mm2 flexible with cable end | 3P | 40 cyc/h | IEC 60947-2 6 kV | TH | TeSys GV2 | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Motor | Rotary knob | 1.8 W | 960 °C conforming to IEC 60695-2-1 | Shocks: 30 Gn conforming to IEC 60068-2-27 Vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6 | AC | 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Magnetic | 223 A | Continuous conforming to IEC 60947-4-1 | Yes conforming to IEC 60947-1 |
GV2L22 | GV2L | 35 mm symmetrical DIN rail: clipped Panel: screwed (with 2 x M4 screws) | 100000 cycles for AC-3 at 415 V | 100000 cycles | 45 mm | 89 mm | 97 mm | 0.33 kg | IP20 conforming to IEC 60529 | EN/IEC 60947-2 EN/IEC 60947-4-1 CSA C22.2 No 60947-4-1 UL 60947-4-1 | -20 to 60 °C | -40 to 80 °C | IECEE CB Scheme UL CSA CCC EAC RINA LROS (Lloyds register of shipping) DNV-GL BV | Green Premium product | Compliant EU RoHS Declaration | Yes | Yes | China RoHS declaration | Product Environmental Profile | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0...2000 m | REACH Declaration | 18 months | 9 kW at 400/415 V AC 50/60 Hz 11 kW at 400/415 V AC 50/60 Hz 11 kW at 500 V AC 50/60 Hz 15 kW at 500 V AC 50/60 Hz 18.5 kW at 690 V AC 50/60 Hz | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 | 50/60 Hz conforming to IEC 60947-2 | 1.7 N.m on screw clamp terminals | Any position | TeSys | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | IK04 | Screw clamp terminals 2 cable(s) 1 to 6 mm2 solid Screw clamp terminals 2 cable(s) 1.5 to 6 mm2 flexible without cable end Screw clamp terminals 2 cable(s) 1 to 4 mm2 flexible with cable end | 3P | 40 cyc/h | IEC 60947-2 6 kV | TH | TeSys GV2 | 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 | Motor | Rotary knob | 1.8 W | 960 °C conforming to IEC 60695-2-1 | Shocks: 30 Gn conforming to IEC 60068-2-27 Vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6 | AC | 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Magnetic | 327 A | Continuous conforming to IEC 60947-4-1 | Yes conforming to IEC 60947-1 |
Part Number |
---|
GV2L22 |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | Magnetic tripping current |
---|---|---|---|---|---|---|
฿ 2,553.00 ฿ 1,802.16 | MOTOR STARTERS 3P 25 A | 1 Piece(s) | 60 Day(s) | 327 A |
Loading...
Rated block capacity AC 100 V(kA) | - | Rated block capacity AC 200 V(kA) | - | Rated block capacity AC 400 V(kA) | - |
---|---|---|---|---|---|
Rated Braking Capacity at Rated Voltage of VDC 250(kA) | - | Dimension height(mm) | 89 mm | Dimension width(mm) | 45 mm |
Dimension depth(mm) | 97 mm | Number of Poles | 3P | Minimum Operating Temperature | 60 °C |
Maximum Operating Temperature | -20°C | Control Type | Rotary knob | Power dissipation per pole | 1.8 W |
Please check the type/dimensions/specifications of the part GV2L22 in the Motor Circuit Breaker TeSys GV2 with rotary knob series.
Part Number |
---|
GV2L03 |
GV2L05 |
GV2L06 |
GV2L07 |
GV2L08 |
GV2L16 |
Part Number | Price | Minimum Order Qty | Volume Discount | Days to Ship | Magnetic tripping current |
---|---|---|---|---|---|
฿ 1,985.67 | 1 Piece(s) | 60 Day(s) | 5 A | ||
฿ 1,985.67 | 1 Piece(s) | 60 Day(s) | 13 A | ||
฿ 1,985.67 | 1 Piece(s) | 60 Day(s) | 22.5 A | ||
฿ 1,985.67 | 1 Piece(s) | 60 Day(s) | 33.5 A | ||
฿ 1,985.67 | 1 Piece(s) | 60 Day(s) | 51 A | ||
฿ 2,201.50 | 1 Piece(s) | 60 Day(s) | 170 A |