(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.
Select part number to Order Now/ Add to Cart
Schneider Electric Acti9 i60N MCBs 2 PoleActi 9 iC60N series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overload currents it also protects people against indirect contact with TN and IT neutral systems. Fully compliant with standards IEC/EN 60898 and IEC/EN 60947-2. ACTi 9 is fully tested, approved and certified by national and international third parties. It guarantees that your installation is safe and compliant with all relevant safety standards which demonstrates to your customers that you use industry-approved materials and best practices. These MCBs are normally used for high inductive loads where switching surges are high. Providing essential protection in industrial and commercial buildings, these miniature circuit breakers work especially well in polluted environments and networks.VisiSafe guarantees the downstream circuit is always safe regardless of overvoltage conditions, even in the most demanding environments; the green strip indicates the safe position of contacts.VisiTrip red window on the front face indicates fault tripping allowing fast diagnosis, resolution, and reclosing loads for easier building management and reduced downtimeBenefits and FeaturesDownstream circuit is always safe Class insulation ensures continuous protection for both operators and unqualified persons. Insulated terminals (IP20) Highly durable with robust connections that provide twice the standard tighteningProvide greater continuity of service thanks to VisiTrip. Double clip dismounting with comb busbar in placeStandardsIEC 60898 - Relates to Low Voltage Circuit Breakers for use in household and similarInstallations. In the UK traditionally known as miniature circuit breakers (MCB’s).IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similarInstallations. In the UK traditionally known as moulded case circuit breakers (MCCB’s) and also air circuit breakers (ACB’s).Q: What is the differences in the Tripping Curves B, C, and D?A: Curve B: Tripping: 3 to 5 times the rated current.Applications: protection of generators, persons, very long cables Curve C: Tripping: 5 to 10 times the rated currentApplications: protection of circuits and general applicationsCurve D: Tripping: 10 to 14 times the rated current Applications: protection of high surge circuits, welders, transformers and motorsA9F74202 Schneider ElectricThis model has tripping curve type C that trips instantly at a rate of five to ten times its rated current. 2 pole. Breaking capacity of 6 kA. Current rating 2 AMerlin Gerin – MCBsMiniature Circuit Breakers; Contact Position indicated by switch leversSchneider Electric Acti9 i60N MCBs 2 PoleActi 9 iC60N series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overload currents it also protects people against indirect contact with TN and IT neutral systems. Fully compliant with standards IEC/EN 60898 and IEC/EN 60947-2. ACTi 9 is fully tested, approved and certified by national and international third parties. It guarantees that your installation is safe and compliant with all relevant safety standards which demonstrates to your customers that you use industry-approved materials and best practices. These MCBs are normally used for high inductive loads where switching surges are high. Providing essential protection in industrial and commercial buildings, these miniature circuit breakers work especially well in polluted environments and networks.VisiSafe guarantees the downstream circuit is always safe regardless of overvoltage conditions, even in the most demanding environments; the green strip indicates the safe position of contacts.VisiTrip red window on the front face indicates fault tripping allowing fast diagnosis, resolution, and reclosing loads for easier building management and reduced downtime
Rated block capacity AC 100 V(kA) | - | Rated block capacity AC 200 V(kA) | - | Rated block capacity AC 400 V(kA) | - |
---|---|---|---|---|---|
Rated Braking Capacity at Rated Voltage of VDC 250(kA) | - | Rated Current(A) | 2 A | Dimension width(mm) | 36mm |
Range | Acti 9 | Number of Poles | 2 | Series | iC60N |
Tripping Characteristics | Type C | Rated AC Voltage | 12 to 60 V, 100 to 130 V, 220 to 240 V, 380 to 415 V, 400 V, 440 V | Rated DC Voltage | 12 to 144V |
Breaking Capacity | 6 kA |
Please check the type/dimensions/specifications of the part A9F74202 in the Acti 9 iC60N MCB Mini Circuit Breaker 2P series.
How can we improve?
How can we improve?