Molded Case Circuit Breakers (MCCB) NF-SVFU Series with accessories

Caution
- This product belongs in RoHS Directive under Category 9 "Monitoring and control equipment" with exclusion from the usage restriction of phthalate esters until 21 July 2021.
- Product image is a representative image. The actual item varies according to the model number. Please bear this in mind.
Product Description
Mitsubishi low-voltage breaker contributing to building the future of electrical equipment.
Mitsubishi No-Fuse Breakers and Earth Leakage Circuit Breakers, meeting the needs of the market for over half a century.
Including the new WS-V series equipped with the latest breaker technology, various product ranges are available that address the needs of both the power incoming panel / distribution board market and machinery market.
Product Specifications of MITSUBISHI Circuit Breakers
| Part Number Circuit Breakers | NF125-SVU | NF125-HVU | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Rated current In Standard ambient temperature 40°C A | 15 20 30 40 50 60 (70) 75 (80) (90) 100 | 125 | 15 20 30 40 50 60 (70) 75 (80) (90) 100 | 125 | |||||
| Number of Positions | 2 | 3 | 2 | 3 | 3 | 3 | |||
| Rating Short circuit Break Capacity kA | UL489 CSA C22.2 No.5-02 | Rated voltage V AC | 480 | 480 | 600Y/347 V | 600Y/347 V | |||
| AC | 600Y/347 V | - | - | 18 | 18 | ||||
| 480 V | 30 | 30 | 50 | 50 | |||||
| 240 V | 50 | 50 | 100 | 100 | |||||
| 120 V | - | - | - | - | |||||
| JIS C 8201-2-1 Ann.1 IEC 60947-2 EN 60947-2 (lcu/lcs) | Rated insulation voltage Ui V | 690 | 690 | 690 | 690 | ||||
| AC | 690 V | 8/4 | 8/4 | 10/5 | 10/5 | ||||
| 500 V | 18/9 | 18/9 | 25/13 | 25/13 | |||||
| 440 V | 30/15 | 30/15 | 50/25 | 50/25 | |||||
| 415 V | 30/15 | 30/15 | 50/25 | 50/25 | |||||
| 400 V | 30/15 | 30/15 | 50/25 | 50/25 | |||||
| 380 V | 30/15 | 30/15 | 50/25 | 50/25 | |||||
| 230 V | 50/25 | 50/25 | 100/50 | 100/50 | |||||
| GB 14048.2 (lcu/lcs) | AC | 415 V | 30/15 | 30/15 | 50/25 | 50/25 | |||
| 400 V | 30/15 | 30/15 | 50/25 | 50/25 | |||||
| 380 V | 30/15 | 30/15 | 50/25 | 50/25 | |||||
| 230 V | 50/25 | 50/25 | 100/50 | 100/50 | |||||
| Parts included as standard (Surface type) | Mounting screws M4 × 0.7 × 55 (2 pcs.), Insulation barrier (2-position 2 sheets, 3-position 4 sheets) | ||||||||
| Part Number Circuit Breakers | NF250-SVU | NF250-HVU | |||||
|---|---|---|---|---|---|---|---|
| Rated current In Standard ambient temperature 40°C A | 125 150 175 200 225 | 250 | 125 150 175 200 225 | 250 | |||
| Number of Positions | 3 | 3 | 3 | 3 | |||
| Rating Short circuit Break Capacity kA | UL489 CSA C22.2 No.5-02 | Rated voltage V AC | 480 | 480 | 600Y/347 V | 600Y/347 V | |
| AC | 600Y/347 V | - | - | 18 | 18 | ||
| 480 V | 35 | 35 | 50 | 50 | |||
| 240 V | 65 | 65 | 100 | 100 | |||
| 120 V | - | - | - | - | |||
| JIS C 8201-2-1 Ann.1 IEC 60947-2 EN 60947-2 (lcu/lcs) | Rated insulation voltage Ui V | 690 | 690 | 690 | 690 | ||
| AC | 690 V | 8/4 | 8/4 | 10/5 | 10/5 | ||
| 500 V | 25/13 | 25/13 | 36/18 | 36/18 | |||
| 440 V | 36/18 | 36/18 | 50/25 | 50/25 | |||
| 415 V | 36/18 | 36/18 | 50/25 | 50/25 | |||
| 400 V | 36/18 | 36/18 | 50/25 | 50/25 | |||
| 380 V | 36/18 | 36/18 | 50/25 | 50/25 | |||
| 230 V | 65/33 | 65/33 | 100/50 | 100/50 | |||
| GB 14048.2 (lcu/lcs) | AC | 415 V | 36/18 | 36/18 | 50/25 | 50/25 | |
| 400 V | 36/18 | 36/18 | 50/25 | 50/25 | |||
| 380 V | 36/18 | 36/18 | 50/25 | 50/25 | |||
| 230 V | 65/33 | 65/33 | 100/50 | 100/50 | |||
| Parts included as standard (Surface type) | Mounting screws M4 × 0.7 × 55 (2 pcs.), Insulation barrier (4 pcs.) | ||||||
Dimensional Drawing of MITSUBISHI Circuit Breakers

Circuit Breakers Surface type
NF125-SVU, NF125-HVU

With surface type solderless terminal
NF125-SVU, NF125-HVU

Circuit Breakers Surface type
NF250-SVU, NF250-HVU

With surface type solderless terminal
NF250-SVU, NF250-HVU