(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.
Select part number to Order Now/ Add to Cart
For convenience, the suffix "-MSM" has been added.
MISUMI warranty is of course valid and Omron provide a 1-year-long warranty from time of purchase.
Timer is shaped similarly to the H3Y, and supports multiple time ranges and multiple operating modes.
[Features]
· High accuracy with a repeated measurement error of ±1% (including first time value).
· Time is easily set by means of the large dial, using either a straight-slot or Philips-head screwdriver.
· EN61812-1 compatible, conforms to the CE mark.
· Supports multiple time ranges with switch-over between 4 ranges.
· Supports multiple operating modes providing 4 functions in 1 device.
· MY shape relay and terminal compatible.
· Compatible with the EN standard allowing export to Europe.
· A semi-multi power supply voltage range greatly reduces the number of maintenance supplies kept in stock.
[Applications]
· The timer acts as control machine, switching the output signal at the preset time after the start signal is input.
H3YN external appearance
Model | Series H3YN-2/-4 | Model H3YN-21/-41 | |
---|---|---|---|
Accuracy Of Operating Time | ±1% max.(at maximum scale time) (1 s range: ±1% ±10 ms max.) | ||
Setting Error | ±10% ±50 ms max. (at maximum scale time) | ||
Reset Time | 0.1 s max. (including halfway reset) | ||
Influence of voltage | ±2% max. (at maximum scale time) | ||
Influence of temperature | ±2% max. (at maximum scale time) | ||
Insulation resistance | 100 MΩ min. (measurement at 500 V DC) | ||
Dielectric Strength | 2,000 V AC, 50/60 Hz, 1 min (between current-carrying terminals and exposed non-current-carrying metal parts excluding terminal screw sections) 2,000 V AC, 50/60 Hz, 1 min (between operating power circuit and control output) 2,000 V AC, 50/60 Hz, 1 min (between different pole contacts; 2-pole model) 1,500 V AC, 50/60 Hz, 1 min (between different pole contacts; 4-pole model) 1,000 V AC, 50/60 Hz, 1 min (between non-continuous contacts) | ||
Vibration | Endurance | 10 to 55 Hz, 0.75-mm single amplitude for 1 h each in 3 directions | |
Malfunction | 10 to 55 Hz, 0.5-mm single amplitude for 10 min each in 3 directions | ||
Shock | Endurance | 1,000 m/s2, 6 directions, 3 times each*1 | |
Malfunction | 100m/s2, 6 directions, 3 times each | ||
Life Expectancy | Mechanical | 10 million operations min. (under no load at 1,800 operations/h) | |
Electrical | 2-pole, 500,000 operations min. (5 A at 250 V AC, resistive load at 1,800 operations/h) (room temperature) 4-pole, 200,000 operations min. (H3YN-4-Z/-41-Z: 100,000 operations min.) (room temperature)*2 | ||
Impulse Withstand Voltage | Between power terminals: 3 kV (however, 1 kV for 12 V DC, 24 V DC, 48 V DC, 24 V AC Between exposed non-current-carrying metal parts: 4.5 kV (however, 1.5 kV for 12 V DC, 24 V DC, 48 V DC, 24 V AC) | ||
Noise resistance | ±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) | ||
Static Immunity | Malfunction: 4 kV Destruction: 8 kV | ||
Protective structure | IP40 | ||
Weight | Approx. 50 g |
*1. Conditions when carrying out shock resistance testing with the timer alone.
*2. Refer to the Life-Test Curve.
Series H3YN-2, H3YN-21 Dimensional Drawing A
Series H3YN-2, H3YN-21 Dimensional Drawing B
Series H3YN-2, H3YN-21 Mount Hole Processing Dimensional Drawing
Series H3YN-4, H3YN-41, H3YN-4-Z Dimensional Drawing A
Series H3YN-4, H3YN-41, H3YN-4-Z Dimensional Drawing B
Series H3YN-4, H3YN-41, H3YN-4-Z Mount Hole Processing Dimensional Drawing
Part Number |
---|
H3YN-2 AC200-230-MSM |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship |
---|---|---|---|---|---|
฿ 1,472.99 ฿ 773.61 | TIMER/CALENDER | 1 Piece(s) | Same day |
Loading...
Type | Timer | Display method | Analog | Time specifications(s) | 0.1 s to 10 m |
---|---|---|---|---|---|
Power Supply Voltage | AC-dedicated | Output Method | Relay | Representative Standard | CE / UL / CCC / CSA |
Dimension vertical(mm) | 28 | Dimension width(mm) | 21.5 | Dimension depth(mm) | 52.6 |
Rated power supply voltage(V) | 200 to 230 V AC | Time ranges = N | 4 range | Contact Configuration | Time limit 2c |
Terminal shape | Plug-in terminal |
Please check the type/dimensions/specifications of the part H3YN-2 AC200-230-MSM in the [Special Price Sellout Product, Only Available While Stocks Last] Solid-state Timer H3YN series.
How can we improve?