Switching Power Supplies RWS-B Series Unit Type

Caution
- [Information for recommended related products]
Cable Clamp with Urethane to Save Space
Dsub Connector Harness (Molded)
Product Description
Simple function model, long life
[Features]
· A simple function model that maintains basic performance and optimizes additional functions.
· Long life: Life of electrolytic capacitor is 5 years or more (Ta=40℃, load factor 100%, 24h/day operation).
· A standard model with a cover is available.
· A DIN rail mounting type and the same mounting bracket are available as options (50/100/150/300W 24V output type with DIN rail mounting bracket product lineup).
· UL508 standard compatible (150W or less 5/12/24V output type, 300W other than 5V output type, 600W 24V output type).
· Medical standard compliant model (/ME) is available for 1000/1500W model (medical standard insulation class 2 x MOPP compatible).
RWS-B Series: 50W to 1500W Single Output General Purpose Power Supplies

Product picture of RWS-B Series, 50W to 600W

Product picture of RWS-B Series, 1000W to 1500W
Features and Benefits of RWS-B Series
• 10 Year e-cap Lifetime
• 7 Year Warranty
• Global Safety Approvals
• Compact Size
• Better Field Reliability
• Lower Cost of Ownership
• Supports Worldwide Use
• Easier System Integration
Specifications of RWS-B Series
| Model | RWS50B | RWS100B | RWS150B | RWS300B | RWS600B | |
|---|---|---|---|---|---|---|
| AC Input Voltage range (1) | VAC | 85 - 265VAC (47 - 63Hz), 300VAC for 5 seconds | ||||
| Inrush Current (100 / 200VAC) | A | 18 / 36 | 15 / 30 | 16 / 32 | 17 / 34 | 20 / 40 |
| Power Factor (100 / 200VAC) | - | Meets EN61000-3-2 | ||||
| Input Current (115/230VAC) (typ) | A | 1.1 / 0.65 | 1.2 / 0.65 (5V model 0.9/0.45) | 1.8 / 0.9 (5v model 1.3/0.7) | 3.6 / 1.9 (5v model 3.1/1.6) | 6.6 / 3.6 (5v model 6.2/3.2) |
| DC Input | VDC | 120 - 370VDC | 120 - 330VDC | |||
| Temperature Coefficient | - | <0.02%/°C | ||||
| Regulation | - | See table | ||||
| Overcurrent Protection | - | >105%, 5V & 12V constant current limit & hiccup autorecovery, 24V &48V constant current limit with autorecovery | ||||
| Overvoltage Protection | V | 115-140%, Cycle AC line to reset | ||||
| Hold Up Time (typ at full load) | ms | 20ms | ||||
| Leakage Current (max) | uA | 750uA maximum, typically 175uA at 115VAC, 63Hz | ||||
| Remote Sense | - | No | ||||
| Remote ON/OFF Control (4) | - | - | - | - | Option | Option |
| Parallel Operation | - | - | - | - | - | Option |
| Operating Temperature (1) | - | -20° to +70°C, derate above 45°C for 50W &100W, 40°C for 150W & 50°C for 300W & 600W (see graphs below) | ||||
| Storage Temperature | - | -30° to +75°C | ||||
| Operating Humidity (non condensing) | %RH | 30 - 90 | ||||
| Storage Humidity (non condensing) | %RH | 10 - 90 | ||||
| Cooling | - | Convection | Internal Fan | |||
| Withstand Voltage | - | Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. | ||||
| Isolation Resistance | - | >100M at 25°C & 70%RH, Output to Ground 500VDC | ||||
| Vibration (non operating) | - | 10 - 55Hz: 19.6m/s2 (sweep 1 min) X, Y, Z for 1 hour | ||||
| Shock | - | < 196.1 m/s2 | ||||
| Safety Agency Approvals (2) (3) | - | IEC/EN/UL/CSA60950-1, IEC/EN/UL/CSA62368-1, UL508 and CE Mark | ||||
| Line Dips | - | SEMI-F47 (200VAC input) | ||||
| Conducted & Radiated EMI | - | EN55011 / EN55022-B, FCC Class B, VCCI-B | ||||
| Immunity | - | IEC61000-4-2, -3, -4, -5, -6, -8, -11 | ||||
| Weight (Typ) | g | 230 | 400 | 480 | 900 | 1600 |
| Size (WxHxD) | mm | 82 x 34 x 81.5 | 94 x 39 x 108 | 94 x 41 x 128 | 102 x 41 x 170 | 120 x 61 x 190 |
| MTBF (5) | hours | 4,170,949 | 1,978,533 | 2,235,743 | 2,027,824 | 2,157,340 |
| Warranty | Yrs | 7 | ||||
| Model | RWS1000B | RWS1500B | |
|---|---|---|---|
| AC Input Voltage range (1) | VAC | 85 - 265VAC (47 - 63Hz) | |
| DC Input Voltage range* | VDC | 120 - 340VDC* | |
| Inrush Current (100 / 200VAC) | A | 60 / 60A | |
| Power Factor (100 / 200VAC) | - | Meets EN61000-3-2 (0.98 / 0.95) | |
| Input Current (100/200VAC) (Typ) | A | 13 / 7A 19 / 10A | |
| Temperature Coefficient | %/°C | <0.02%/°C | |
| Regulation | - | See Model Selector | |
| Overcurrent Protection | - | >105%, Constant Current Style. After 5s unit will shutdown | |
| Overvoltage Protection (2) | V | Shuts down output, cycle AC line or remote on/off to reset | |
| Hold Up Time (Typ at 100% load) | ms | 20ms | |
| Leakage Current (max) | mA | <1.2mA | |
| Standby Voltage (Vsb) | - | 5V 1A (always on). See options table (/S suffix) | |
| Remote Sense | - | Yes | |
| Remote On/Off | - | See options table. Apply external voltage or Vsb to enable output voltage | |
| DC Good, Fan Alarm | - | See options table | |
| Parallel Operation | - | See options table | |
| Series Operation | - | Yes | |
| Operating Temperature | °C | -20 to +60°C, derate linearly to 60% load from 50 to 60°C Reverse air (/RF): -20 to +70°C, derate linearly to 50% load from 50 to 70°C | |
| Storage Temperature | °C | -30 to +75°C | |
| Operating Humidity (non condensing) | %RH | 20 - 90%RH | |
| Storage Humidity (non condensing) | %RH | 10 - 90%RH | |
| Cooling | - | Internal Fan, air intake from input/output terminals | |
| Withstand Voltage | VAC | Input to Ground 2kVAC, Input to Output 4kVAC, Output to Ground 1.5kVAC for 1 min. | |
| Isolation Resistance | MΩ | >100MΩ at 25°C & 70%RH, Output to Ground 500VDC | |
| Vibration (non operating) | - | 10 - 55Hz: 19.6m/s2 (sweep 1 min) X, Y, Z for 1 hour | |
| Shock | - | < 196.1 m/s2 | |
| Safety Agency Certifications | - | IEC/UL/CSA/EN60950-1, IEC/UL/CSA/EN62368-1, CE Mark | |
| Line Dips | - | SEMI-F47 (200VAC input) | |
| Conducted & Radiated EMI | - | EN55011 / EN55032-B, FCC Class B, VCCI-B | |
| Immunity | - | IEC61000-4-2, -3, -4, -5, -6, -8, -11, IEC61000-6-2 | |
| Weight (Typ) | g | 2,000g | 3,000g |
| Size (WxHxD) | mm | 127 x 63 x 198mm | 127 x 63 x 261mm |
| In | 5 x 2.48 x 7.8" | 5 x 2.48 x 10.28" | |
| MTBF - Telcordia SR-332 issue 3** | hours | 1,834,313 | 1,222,361 |
| Warranty | yrs | Seven Years | |
(1) Derate linearly to 80% load from 90 to 85VAC input *Safety certified for AC input only **24V output model, 25°C ambient, full load, 230VAC input
(2) See specifications on website for individual limits. Note the remote on/off function is an option - see options table
Outline Drawing

Outline drawing RWS50B Series

Outline drawing RWS100B Series

Outline drawing RWS150B Series

Outline drawing RWS300B Series

Outline drawing RWS600B Series

Outline drawing RWS1000B