Key Switch

Caution
Product Description
Schneider key switches are manually operated by turning a key. Various switch versions are available enabling the operator to gain a clear visual indication of the switched position and the commands required for the electrical control of equipment.
Keys can be removed or may "stay-put" in different positions (switch type dependent). Please refer to the manufacturers datasheet for specific details. Some models have spring return features, that enables the key to activate the switch, then return to the original 'home' key position.
| Product Code | Range of product | Product or component type | Vibration resistance | Shock resistance | Mechanical durability | Net weight | IP degree of protection | Standards | Ambient air temperature for operation | Ambient air temperature for storage | Product certifications | Sustainable offer status | EU RoHS Directive | Mercury free | RoHS exemption information | Environmental Disclosure | REACh Regulation | Warranty | Protective treatment | Head type | Device short name | Width | Height | Depth | NEMA degree of protection | China RoHS Regulation | Circularity Profile | Sale per indivisible quantity | mUin rated insulation voltage | IK degree of protection | Mounting diameter | Contacts type and composition | Bezel material | Short-circuit protection | [Uimp] rated impulse withstand voltage | Contact operation | Positive opening | Type of operator | Shape of signaling unit head | Operator profile | Device presentation | Resistance to high pressure washer | [Ie] rated operational current | Type of keylock | Key withdrawal position | Electrical durability | WEEE | Tightening torque | [Ith] conventional free air thermal current | Connections - terminals | Terminals description ISO n°1 | Contacts material | Operator position information | Contacts usage | Shape of screw head | Electrical reliability | Torque value | Overvoltage category | Electrical shock protection class | Fixing collar material | Cable entry | Material | Local signalling | Product destination | Electrical connection | Component name | [Ithe] conventional enclosed thermal current | Maximum operating rate | CAD overall width | CAD overall height | CAD overall depth | Design | Number of poles | Safety level | Safety reliability data | Reset | Station name | Electrical composition code | Body material | Locking options description | Minimum actuation speed | Head material | Maximum actuation speed | Minimum actuator force for extraction | Cable outer diameter |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| XB4BG21 | Harmony XB4 | Selector switch | 5 gn (f= 2 to 500 Hz) conforming to IEC 60068-2-6 | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | 1000000 cycles | 0.117 kg | IP66 conforming to IEC 60529 IP69 IP69K IP67 | JIS C8201-5-1 EN/IEC 60947-5-5 EN/IEC 60947-1 UL 508 EN/IEC 60947-5-4 CSA C22.2 No 14 EN/IEC 60947-5-1 JIS C8201-1 | -40 to 70 °C | -40 to 70 °C | UL BV DNV CSA RINA GL LROS (Lloyds register of shipping) | Green Premium product | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | Yes | Yes | Product Environmental Profile | REACh Declaration | 18 months | TH | Standard | XB4 | 30 mm | 47 mm | 86 mm | NEMA 13 NEMA 4X | China RoHS declaration | End of Life Information | 1 | 600 V (pollution degree 3) conforming to EN 60947-1 | IK06 with keyhole cover ZBGP conforming to IEC 50102 | 22 mm | 1 NO | Chromium plated metal | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | 6 kV EN 60947-1 | Slow-break | Without | Stay put | Round | Key switch | Complete product | 7000000 Pa at 55 °C, distance : 0.1 m | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | Ronis 455 | Left-hand | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0.8 to 1.2 N.m conforming to EN 60947-1 | 10 A conforming to EN/IEC 60947-5-1 | Screw clamp terminals, <= 2 x 1.5 mm2 with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm2 without cable end conforming to EN/IEC 60947-1 | (13-14)NO | Silver alloy (Ag/Ni) | 2 positions 90° | Standard contacts | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver | ƒฉ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 ƒฉ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 | 0.14 N.m NO changing electrical state | Class I conforming to IEC 60536 | - | Zamak | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| XB4BG61 | Harmony XB4 | Selector switch | 5 gn (f= 2 to 500 Hz) conforming to IEC 60068-2-6 | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | 1000000 cycles | 0.117 kg | IP66 conforming to IEC 60529 IP69 IP69K IP67 | JIS C8201-5-1 EN/IEC 60947-1 CSA C22.2 No 14 EN/IEC 60947-5-1 EN/IEC 60947-5-4 EN/IEC 60947-5-5 UL 508 JIS C8201-1 | -40 to 70 °C | -40 to 70 °C | LROS (Lloyds register of shipping) CSA UL DNV BV RINA GL | Green Premium product | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | Yes | Yes | Product Environmental Profile | REACh Declaration | 18 months | TH | Standard | XB4 | 30 mm | 47 mm | 86 mm | NEMA 13 NEMA 4X | China RoHS declaration | End of Life Information | 1 | 600 V (pollution degree 3) conforming to EN 60947-1 | IK06 with keyhole cover ZBGP conforming to IEC 50102 | 22 mm | 1 NO | Chromium plated metal | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | 6 kV EN 60947-1 | Slow-break | Without | Right to left spring return | Round | Key switch | Complete product | 7000000 Pa at 55 °C, distance : 0.1 m | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | Ronis 455 | Left-hand | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0.8 to 1.2 N.m conforming to EN 60947-1 | 10 A conforming to EN/IEC 60947-5-1 | Screw clamp terminals, <= 2 x 1.5 mm2 with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm2 without cable end conforming to EN/IEC 60947-1 | (13-14)NO | Silver alloy (Ag/Ni) | 2 positions 90° | Standard contacts | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver | ƒฉ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 ƒฉ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 | 0.14 N.m NO changing electrical state | Class I conforming to IEC 60536 | - | Zamak | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| XB5AG21 | Harmony XB5 | Selector switch | 5 gn (f= 2 to 500 Hz) conforming to IEC 60068-2-6 | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | 1000000 cycles | 0.831 kg | IP69 IP69K IP66 conforming to IEC 60529 IP67 | UL 508 CSA C22.2 No 14 EN/IEC 60947-5-1 EN/IEC 60947-5-4 EN/IEC 60947-1 JIS C8201-5-1 JIS C8201-1 | -40 to 70 °C | -40 to 70 °C | RINA LROS (Lloyds register of shipping) CSA DNV GL BV UL | Green Premium product | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | Yes | Yes | Product Environmental Profile | REACh Declaration | 18 months | TH | Standard | XB5 | 30 mm | 42 mm | 96 mm | NEMA 13 NEMA 4X | China RoHS declaration | End of Life Information | 1 | 600 V (pollution degree 3) conforming to EN 60947-1 | IK06 conforming to IEC 50102 | 22 mm | 1 NO | Dark grey plastic | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | 6 kV EN 60947-1 | Slow-break | Without | Stay put | Round | Key switch | Complete product | 7000000 Pa at 55 °C, distance : 0.1 m | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | Ronis 455 | Left-hand | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0.8 to 1.2 N.m conforming to EN 60947-1 | 10 A conforming to EN/IEC 60947-5-1 | Screw clamp terminals, <= 2 x 1.5 mm2 with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm2 without cable end conforming to EN/IEC 60947-1 | (13-14)NO | Silver alloy (Ag/Ni) | 2 positions 90° | Standard contacts | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver | ƒฉ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to EN/IEC 60947-5-4 ƒฉ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to EN/IEC 60947-5-4 | 0.14 N.m NO changing electrical state | - | Class II conforming to IEC 60536 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| XB5AG41 | Harmony XB5 | Selector switch | 5 gn (f= 2 to 500 Hz) conforming to IEC 60068-2-6 | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | 1000000 cycles | 0.831 kg | IP69 IP69K IP66 conforming to IEC 60529 IP67 | EN/IEC 60947-5-1 CSA C22.2 No 14 UL 508 EN/IEC 60947-1 EN/IEC 60947-5-4 JIS C8201-5-1 JIS C8201-1 | -40 to 70 °C | -40 to 70 °C | CSA UL LROS (Lloyds register of shipping) BV GL DNV RINA | Green Premium product | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | Yes | Yes | Product Environmental Profile | REACh Declaration | 18 months | TH | Standard | XB5 | 30 mm | 42 mm | 96 mm | NEMA 13 NEMA 4X | China RoHS declaration | End of Life Information | 1 | 600 V (pollution degree 3) conforming to EN 60947-1 | IK06 conforming to IEC 50102 | 22 mm | 1 NO | Dark grey plastic | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | 6 kV EN 60947-1 | Slow-break | Without | Stay put | Round | Black key switch | Complete product | 7000000 Pa at 55 °C, distance : 0.1 m | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | Ronis 455 | In any position | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins | 0.8 to 1.2 N.m conforming to EN 60947-1 | 10 A conforming to EN/IEC 60947-5-1 | Screw clamp terminals, <= 2 x 1.5 mm2 with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm2 without cable end conforming to EN/IEC 60947-1 | (13-14)NO | Silver alloy (Ag/Ni) | 2 positions 90° | Standard contacts | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver | ƒฉ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to EN/IEC 60947-5-4 ƒฉ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to EN/IEC 60947-5-4 | 0.14 N.m NO changing electrical state | - | Class II conforming to IEC 60536 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| XCSA701 | Preventa Safety detection | Safety switch | 5 gn (f= 10 to 500 Hz) conforming to IEC 60068-2-6 | 10 gn for 11 ms conforming to IEC 60068-2-27 | 1000000 cycles | 0.44 kg | IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 | EN/IEC 60947-5-1 CSA C22.2 No 14 EN/ISO 12100 EN 1088/ISO 14119 UL 508 EN/IEC 60204-1 | -25 to 70 °C | -40 to 70 °C | CSA UL | Green Premium product | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | Yes | Yes | Product Environmental Profile | REACh Declaration | 18 months | TC | Key operated turret head | - | 40 mm | 114 mm | 44 mm | - | - | - | - | 300 V conforming to UL 508 500 V conforming to EN/IEC 60947-1 300 V conforming to CSA C22.2 No 14 | - | - | 2 NC + 1 NO | - | 10 A cartridge fuse type gG (gl) | EN/IEC 60947-5-1 6 kV | Slow-break, break before make | With NC contact | - | - | - | - | - | 6 A at 120 V, AC-15, A300 conforming to EN/IEC 60947-5-1 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Class I conforming to EN/IEC 61140 | - | 1 entry tapped for Pg 13.5 | Metal | Without | - | Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm2 with or without cable end | XCSA | 10 A | 10 cyc/mn for maximum durability | - | - | - | Industrial | 3 | Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear | - | - | - | Zamak | Without locking of actuator | 0.01 m/s | Zamak | 0.5 m/s | 20 N | 9 to 12 mm |
| ZB5AS944 | Harmony XB5 | Head | 5 gn (f= 2 to 500 Hz) conforming to IEC 60068-2-6 | 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 | 300000 cycles | 0.071 kg | IP66 conforming to IEC 60529 IP67 IP69 IP69K | IEC 60364-5-53 JIS C8201-5-1 EN/IEC 60947-1 GB 14048.5 EN/IEC 60947-5-5 EN/IEC 60204-1 UL 508 CSA C22.2 No 14 EN/IEC 60947-5-1 EN/ISO 13850 EN/IEC 60947-5-4 JIS C8201-1 | -40 to 70 °C | -40 to 70 °C | BV CSA GL UL listed RINA DNV LROS (Lloyds register of shipping) | Green Premium product | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration | Yes | Yes | Product Environmental Profile | REACh Declaration | 18 months | TH | Standard | ZB5 | - | - | - | NEMA 13 NEMA 4X | China RoHS declaration | End of Life Information | 1 | - | IK03 conforming to IEC 50102 | 22 mm | - | Dark grey plastic | - | - | - | - | Trigger action and mechanical latching | Round | Red mushroom O 40 mm, unmarked | Basic element | 7000000 Pa at 55 °C, distance : 0.1 m | - | Ronis 455 | Center | - | - | - | - | - | - | - | - | - | - | - | - | Class II conforming to IEC 60536 | - | - | - | - | - | Emergency stop push-button | - | - | - | - | 40 mm | 40 mm | 79 mm | - | - | - | - | Key release | XALD 1 cut-out XALK 1 cut-out | C7 for <4 contacts using single blocks in front mounting C8 for <4 contacts using single and double blocks in front mounting C11 for <3 contacts using single blocks in front mounting C15 for <1 contacts using single blocks in front mounting SF1 for <3 contacts using single blocks in front mounting SR1 for <3 contacts using single blocks in rear mounting C10 for <4 contacts using single and double blocks in front mounting | - | - | - | - | - | - | - |