(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.
Select part number to Order Now/ Add to Cart
Single output switched-mode power supply.
[Function]
· Universal AC input/full range.
· Protection: Short / overload / overvoltage / overtemperature.
· Cooling: Natural air cooling.
· POWER-ON LED display.
Part Number |
---|
RS-25-3.3 |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | RoHS | Capacity (W) | Output voltage (Single only) | Rated output current (single only) (A) | Representative Standard | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Output voltage variation range (V) | AC Input Voltage Range | AC Input current (Maximum) | Output Current Range | Effi. | Overload protection | Over voltage protection | Withstand Voltage | Operating temperature | Safety Standard | EMC standards | AC Input Voltage Range | Other authentication/standards |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 576.67 ฿ 494.26 | ENCLOSED POWER SUPPLY | 1 Piece(s) | 95 Day(s) | - | 25 | DC3.3V | 6 | CE / UL / TUV | 28 | 51 | 78 | - | 88 ~ 264VAC, 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) | - | 0 ~ 6A | 73.5% | 110 ~ 180% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed. | 3.8 ~ 4.45V Protection type : Shut off o/p voltage, clamping by zener diode. | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | -20 ~ +70℃ (Refer to "Derating Curve") | UL62368-1, TUV BS EN/EN62368-1 , AS/NZS 62368.1 .1, BSMI CNS14336-1 , BIS IS13252 Part1 2010 IEC 60950 1 2005 approved | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3,GB9254 class B,GB17625.1, EAC TP TC 020, CNS13438 Class B | - | - |
Loading...
Shape | With Cover | Single/multi | Single | Input Voltage | AC/DC |
---|---|---|---|---|---|
Input/output terminal shape | Screw |
Please check the type/dimensions/specifications of the part RS-25-3.3 in the Switching Power Supply 15~150W Mini Watt Multi-Output Enclosed Type, RS Series series.
Part Number |
---|
RS-15-12 |
RS-15-15 |
RS-15-24 |
RS-25-48 |
RS-25-5 |
RS-35-12 |
Part Number | Price | Minimum Order Qty | Volume Discount | Days to Ship | RoHS | Capacity (W) | Output voltage (Single only) | Rated output current (single only) (A) | Representative Standard | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Output voltage variation range (V) | AC Input Voltage Range | AC Input current (Maximum) | Output Current Range | Effi. | Overload protection | Over voltage protection | Withstand Voltage | Operating temperature | Safety Standard | EMC standards | AC Input Voltage Range | Other authentication/standards |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 658.06 | 1 Piece(s) | Same day | - | 15 | DC12V | 1.3 | UL / CE / CCC / TUV | 28 | 51 | 62.5 | - | 85~264VAC,120~370VDC | Cold Start, 65A at 230VAC | 0~1.3 A | 81% | Above 105% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed. | 13.8 ~ 16.2V Protection type : Shut off o/p voltage, clamping by zener diode. | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | -20 ~ +70 (Refer to "Derating Curve") ℃ | UL62368-1, TUV BS EN/EN62368-1 , AS/NZS 62368.1, .1, BSMI CNS14336-1, BIS approved IS13252(Part1):2010/IEC 60950-1: 2005 approved | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/ Class B EN61000-3-2,-3,GB9254 class B,GB17625.1, EAC TP TC 020, CNS13438 | 85 ~ 264VAC, 120 ~ 370VDC | - | ||
฿ 463.33 | 1 Piece(s) | 95 Day(s) | - | 15 | DC12V | 1 | UL / CE / CCC / TUV | 28 | 51 | 62.5 | - | 85~264VAC,120~370VDC | Cold Start, 65A at 230VAC | 0 ~ 1A | 81% | Above 105% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed. | 17.25 ~ 20.25V Protection type : Shut off o/p voltage, clamping by zener diode. | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | -20 ~ +70 (Refer to "Derating Curve") ℃ | UL62368-1, TUV BS EN/EN62368-1 , AS/NZS 62368.1, .1, BSMI CNS14336-1, BIS approved IS13252(Part1):2010/IEC 60950-1: 2005 approved | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/ Class B EN61000-3-2,-3,GB9254 class B,GB17625.1, EAC TP TC 020, CNS13438 | 85 ~ 264VAC, 120 ~ 370VDC | - | ||
฿ 308.33 | 1 Piece(s) | 2 Day(s) | 10 | 15 | DC24V | 0.625 | UL / CE / CCC / TUV | 28 | 51 | 62.5 | - | 85~264VAC,120~370VDC | Cold Start, 65A at 230VAC | 0 ~ 0.625A | 82% | Above 105% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed. | 28.4 ~ 32.4V Protection type : Shut off o/p voltage, clamping by zener diode. | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | -20 ~ +70 (Refer to "Derating Curve") ℃ | UL62368-1, TUV BS EN/EN62368-1 , AS/NZS 62368.1, .1, BSMI CNS14336-1, BIS approved IS13252(Part1):2010/IEC 60950-1: 2005 approved | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/ Class B EN61000-3-2,-3,GB9254 class B,GB17625.1, EAC TP TC 020, CNS13438 | 85 ~ 264VAC, 120 ~ 370VDC | - | ||
฿ 576.67 | 1 Piece(s) | 95 Day(s) | - | 25 | DC48V | 0.57 | UL / CE / TUV | 28 | 51 | 78 | - | 88 ~ 264VAC, 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) | - | 0 ~ 0.57A | 85% | 110 ~ 180% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed. | 55.2 ~ 64.8V Protection type : Shut off o/p voltage, clamping by zener diode. | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | -20 ~ +70℃ (Refer to "Derating Curve") | UL62368-1, TUV BS EN/EN62368-1 , AS/NZS 62368.1 .1, BSMI CNS14336-1 , BIS IS13252 Part1 2010 IEC 60950 1 2005 approved | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3,GB9254 class B,GB17625.1, EAC TP TC 020, CNS13438 Class B | - | - | ||
฿ 774.19 | 1 Piece(s) | Same day | - | 25 | DC5V | 5 | UL / CE / TUV | 28 | 51 | 78 | - | 88 ~ 264VAC, 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) | - | 0 ~ 5A | 78.5% | 110 ~ 180% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed. | 5.75 ~ 6.75V Protection type : Shut off o/p voltage, clamping by zener diode. | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | -20 ~ +70℃ (Refer to "Derating Curve") | UL62368-1, TUV BS EN/EN62368-1 , AS/NZS 62368.1 .1, BSMI CNS14336-1 , BIS IS13252 Part1 2010 IEC 60950 1 2005 approved | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3,GB9254 class B,GB17625.1, EAC TP TC 020, CNS13438 Class B | - | - | ||
฿ 837.50 | 1 Piece(s) | 3 Day(s) | - | 35 | DC12V | 3 | UL / CE / TUV | 36 | 82 | 99 | 10.8 ~ 13.2 | 88 ~ 264VAC, 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) | - | 0 ~ 3A | 84.5% | - | - | - | - | - | - | - | CB (international authentication) |
How can we improve?