Dip Timer H3FA

Brand :
OMRON

Caution

    Product Description

    Timer for mounting on contact and non-contact output type printed circuit boards.
    [Features]
    · Timer for mounting on contact and non-contact output type printed circuit boards.
    · Two types of control outputs are provided: 3 A (at 250 V AC, with resistive load) for contact outputs (1a, 1b), and max. 150 mA at high capacity for non-contact outputs.
    · Multifunctionality realized by 4 time types in one unit: 1 sec. / 10 sec. / 1 min. / 10 min. (type A) or 6 sec. / 60 sec. / 6 min. / 60 min. (type B).
    · Time can be operated remotely through connection to an external varistor.
    · Fully washable.
    · Compact size enables mounting in 1-inch pitch racks (length × width × height: 17.75 × 36.9 × 19.5 mm).
    · Complies with UL/CSA.

    DIP Timer Specifications

    H3FA external appearance

    H3FA external appearance

    H3FA outline drawing

    H3FA outline drawing

    Time Specifications

    FormatMaximum Scale TimeSet Time Range
    Series H3FA-A
    Series H3FA-SA
    Series H3FA-AU
    1 s0.1 to 1 s
    10 s1 to 10 s
    1 min0.1 to 1 min
    Series H3FA-B
    Series H3FA-SB
    Series H3FA-BU
    6 s0.6 to 6 s
    60 s6 to 60 s
    6 min0.6 to 6 min

    Note 1. The above timing ranges apply when the internal variable resistor of Series H3FA is used.
    Note 2. The external variable resistor may also be used by opening the terminal connected to the internal variable resistor.
    Note 3. Wire the appropriate terminal to select a time setting range.

    Performance

    Variations In Operating Time±0.5% or less (percentage relative to maximum scale time) *1 *3
    Set Error0 to +30% or less (percentage relative to maximum scale time, at 20°C, at rated voltage)
    Recovery Time10 ms or less
    Voltage Effect±1% or less (Percentage relative to maximum scale time. However, it is ±2% or less for 5, 6, 5/6 V DC.)
    Temperature Effect±5% or less (percentage relative to maximum scale time) *1
    Insulation Resistance100 MΩ or more (at 500 V DC megger)
    Withstand Voltage1,500 V AC, 50/60 Hz, 1 min (between control output and operation circuit) *2 1,000 V AC, 50/60 Hz, 1 min (between non-continuous contacts) *2
    VibrationEndurance10 to 55 Hz, half amplitude 0.375mm, 3 directions, 2 h each
    Malfunction10 to 55 Hz, half amplitude 0.25mm, 3 directions, 10 min each
    ShockEndurance1,000 m/s2, 3 axes, 6 directions, 3 times each
    Malfunction100 m/s2, 3 axes, 6 directions, 3 times each
    LifeMechanical10 million operations or more (no load, switching frequency 1,800 operations/h) *2
    Electrical100,000 operations or more (250 V AC, 3 A, resistive load, switching frequency 1,800 operations/h) *2
    MassContact output type approx. 15 g, non-contact output type approx. 10 g
    *1. When using a time specification of 1 second, each standard value is ±10 ms.
    * 2. Applies to the contact point type.
    * 3. When using the internal variable resistor of Series H3FA. (Not including when an externally connected resistor is used.)
    Viewed Products
    Recently Viewed Products
    My Components
    My Components
    0
    Cart
    Cart
    Economy Series
    MRO Product

    Chat with MISUMI

    Chat service is available for any inquiry to MISUMI

    Service hours

    9:00 - 18:00 (Mon-Sat)

    For out of service hours, you can leave a message to us.
    We will reply to your inquiries on the next business day.
    (except Sundays and public holidays).

    Noted for use

    Chat service is for Corporate customers and limited for Thai language.

    Request for Quotation and Place Order is not available on Chat.

    Start chat