Dip Timer H3FA

Caution
Product Description
Timer for mounting on contact and non-contact output type printed circuit boards.
[Features]
· Timer for mounting on contact and non-contact output type printed circuit boards.
· Two types of control outputs are provided: 3 A (at 250 V AC, with resistive load) for contact outputs (1a, 1b), and max. 150 mA at high capacity for non-contact outputs.
· Multifunctionality realized by 4 time types in one unit: 1 sec. / 10 sec. / 1 min. / 10 min. (type A) or 6 sec. / 60 sec. / 6 min. / 60 min. (type B).
· Time can be operated remotely through connection to an external varistor.
· Fully washable.
· Compact size enables mounting in 1-inch pitch racks (length × width × height: 17.75 × 36.9 × 19.5 mm).
· Complies with UL/CSA.
DIP Timer Specifications

H3FA external appearance

H3FA outline drawing
Time Specifications
| Format | Maximum Scale Time | Set Time Range |
|---|---|---|
| Series H3FA-A Series H3FA-SA Series H3FA-AU | 1 s | 0.1 to 1 s |
| 10 s | 1 to 10 s | |
| 1 min | 0.1 to 1 min | |
| Series H3FA-B Series H3FA-SB Series H3FA-BU | 6 s | 0.6 to 6 s |
| 60 s | 6 to 60 s | |
| 6 min | 0.6 to 6 min |
Note 1. The above timing ranges apply when the internal variable resistor of Series H3FA is used.
Note 2. The external variable resistor may also be used by opening the terminal connected to the internal variable resistor.
Note 3. Wire the appropriate terminal to select a time setting range.
Performance
| Variations In Operating Time | ±0.5% or less (percentage relative to maximum scale time) *1 *3 | |
|---|---|---|
| Set Error | 0 to +30% or less (percentage relative to maximum scale time, at 20°C, at rated voltage) | |
| Recovery Time | 10 ms or less | |
| Voltage Effect | ±1% or less (Percentage relative to maximum scale time. However, it is ±2% or less for 5, 6, 5/6 V DC.) | |
| Temperature Effect | ±5% or less (percentage relative to maximum scale time) *1 | |
| Insulation Resistance | 100 MΩ or more (at 500 V DC megger) | |
| Withstand Voltage | 1,500 V AC, 50/60 Hz, 1 min (between control output and operation circuit) *2 1,000 V AC, 50/60 Hz, 1 min (between non-continuous contacts) *2 | |
| Vibration | Endurance | 10 to 55 Hz, half amplitude 0.375mm, 3 directions, 2 h each |
| Malfunction | 10 to 55 Hz, half amplitude 0.25mm, 3 directions, 10 min each | |
| Shock | Endurance | 1,000 m/s2, 3 axes, 6 directions, 3 times each |
| Malfunction | 100 m/s2, 3 axes, 6 directions, 3 times each | |
| Life | Mechanical | 10 million operations or more (no load, switching frequency 1,800 operations/h) *2 |
| Electrical | 100,000 operations or more (250 V AC, 3 A, resistive load, switching frequency 1,800 operations/h) *2 | |
| Mass | Contact output type approx. 15 g, non-contact output type approx. 10 g | |
* 2. Applies to the contact point type.
* 3. When using the internal variable resistor of Series H3FA. (Not including when an externally connected resistor is used.)