(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.
Select part number to Order Now/ Add to Cart
[Features]
· A short barrel size of 66.5 mm from the neck down: Multi-mode, ON delay, Instantaneously connected ON delay, OFF delay, star delta, repeat operation type all implemented in a short barrel size of 66.5 mm from the neck down.
· Direct reading timed graduation not requiring conversion to hexadecimal notation is adopted: by using a direct reading timed hexadecimal scale of 30 seconds (minutes) and 60 seconds (minute), it can be set easily (time specification from 0.05 seconds to 60 hours is supported by 1 unit) even without converting the time limit setting such as 56 minutes, 27 minutes to hexadecimal.
· Improved measures in respect of the wave distortion in the power source: Improved resistance to power source wave distortion by use of an inverter and the like.
· An AC free power source: AC100 to 240V sharing of the power source voltage achieved.
· Zero scale instantaneous operation function: When the time period setting is done using a zero scale, because instantaneous output is enabled, sequence checking is simplified.
Part Number |
---|
MS4SF-CE1N |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | RoHS | Power Supply Voltage | Representative Standard | Dimension depth (mm) | Operating Mode | Rated control power supply voltage (V) | Rated time limit | Contact Configuration | Types of operation | Specifications | Time specifications |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 3,075.00 | DISPLAY TIMER CALENDER | 1 Piece(s) | 90 Day(s) | 10 | AC/DC | CE / UL / CSA | 81.5 | OFF delay — operation | AC/DC24V | 0.6–12 min | - | OFF Start | Time Limit 2c | Four range switching for minute-unit products: 0.6–12 min |
Loading...
Type | Timer | Display method | Analog | Dimension vertical(mm) | 48 |
---|---|---|---|---|---|
Dimension width(mm) | 48 | Connection Method | Plug-In |
Please check the type/dimensions/specifications of the part MS4SF-CE1N in the Super Timer MS4S Series series.
Part Number |
---|
MS4SC-AP |
MS4SC-CE |
MS4SC-DL |
MS4SF-CE1NR |
MS4SF-CE1T |
MS4SF-CE1TR |
Part Number | Price | Minimum Order Qty | Volume Discount | Days to Ship | RoHS | Power Supply Voltage | Representative Standard | Dimension depth (mm) | Operating Mode | Rated control power supply voltage (V) | Rated time limit | Contact Configuration | Types of operation | Specifications | Time specifications |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 2,175.00 | 1 Piece(s) | Same day | - | AC-dedicated | CSA / TUV / UL / CE | 81.5 | ON delay — operation | AC100-240V | - | - | OFF Start | Time limit 1c + instant 1c | 16-range switching from 0.6 s – 60 h | ||
฿ 2,175.00 | 1 Piece(s) | 90 Day(s) | 10 | AC/DC | CSA / TUV / UL / CE | 81.5 | ON delay — operation | AC/DC24V | - | - | OFF Start | Time limit 1c + instant 1c | 16-range switching from 0.6 s – 60 h | ||
฿ 2,175.00 | 1 Piece(s) | 90 Day(s) | 10 | Dedicated to DC | CSA / TUV / UL / CE | 81.5 | ON delay — operation | DC48-127V | - | - | OFF Start | Time limit 1c + instant 1c | 16-range switching from 0.6 s – 60 h | ||
฿ 3,075.00 | 1 Piece(s) | 90 Day(s) | 10 | AC/DC | CSA / UL / CE | 81.5 | OFF delay — operation | AC/DC24V | 0.6–12 min | Includes reset | OFF Start | Includes time limit 1c + instant reset | Four range switching for minute-unit products: 0.6–12 min | ||
฿ 3,075.00 | 1 Piece(s) | 90 Day(s) | - | AC/DC | CSA / UL / CE | 81.5 | OFF delay — operation | AC/DC24V | 0.6 to 12s | - | OFF Start | Time Limit 2c | Four range switching for second-unit products: 0.6–12 s | ||
฿ 3,075.00 | 1 Piece(s) | 90 Day(s) | 10 | AC/DC | CSA / UL / CE | 81.5 | OFF delay — operation | AC/DC24V | 0.6 to 12s | Includes reset | OFF Start | Includes time limit 1c + instant reset | Four range switching for second-unit products: 0.6–12 s |
How can we improve?
How can we improve?