Digital panel meter with 2-color LED backlight (red/green).
[Features]
· Highly visible due to a negative LCD display, and can be set easily with front key operation.
· Terminal cover equipped as standard for electric shock prevention; contact, NPN, PNP and voltage pulse inputs supported.
· Equipped with scaling, auto zero time and start-up compensation timer functions, as well as an averaging function for suppression of flickering.
· MAX/MIN display can be checked, and features a built-in (12 V DC, 40 mA) external power supply.
· The front panel has a waterproof and dust-proof structure compliant with protective structure NEMA4X (IP66 equivalent).
· CE marking compliant and UL standard certified (mark license certified).
[Applications]
· Used as various indicators by receiving the rotation speed and flow rate speed through pulse input.
K3MA-F external appearance
K3MA-F dimensional drawing
Units: mm
*Terminal is M3. Terminal cover is included.
K3MA-F main display character size
Units: mm
K3MA-F panel processing dimensional drawing
Units: mm
*Mounting panel thickness is 1 to 8 mm. Mount horizontally.
External Shape | Input Type | Output Type | Power Supply Voltage | |
---|---|---|---|---|
100 to 240 V AC (50/60 Hz) | 24 V AC (50/60 Hz), 24 V DC | |||
96 (W) × 48 (H) × Depth 80 mm | Rotation Pulse Input | NA | Series K3MA-F AC100-240V | Series K3MA-F AC/DC24V |
Relay contact output (2 output, each 1a) | Series K3MA-F-A2 AC100-240V | Series K3MA-F-A2 AC/DC24V |
Power Supply Voltage | 100 to 240 V AC Type: 100 to 240 V AC (50/60 Hz) | 24 V AC/V DC Type: 24 V AC (50/60 Hz), 24 V DC | |
---|---|---|---|
Allowable Voltage Range | 85 to 110% of power supply voltage | ||
Power Consumption (At Maximum Load) | 6 VA or less | 4.5 VA or less (at 24 V AC) 4.5 W or less (at 24 V DC) | |
External Power Supply | 12 V DC (±10%) 0 to 40 mA | ||
Insulation Resistance | 20 MΩ or more (at 500 V DC megger) Between external terminals and case, between input, output, and power supply | ||
Withstand Voltage | 2,000 V AC or more, 1 min, between external terminals and case | ||
Noise Resistance | Power supply terminal normal / common mode ±1,500 V, rise 1 ns wave ±1 μs, 100 ns | Power supply terminal normal mode ±480 V, power common mode ±1,500 V, rise 1 ns wave ±1 μs, 100 ns | |
Vibration-Resistant | Frequency: 10 to 55 Hz, half amplitude: 0.35 mm, 5 min each in X, Y, Z directions × 10 sweeps | ||
Shock-Resistant | 150 m/s2 (however, 100 m/s2 for relay contact), 3 axes, 6 directions, 3 times each | ||
Operating Temperature Range | When In Use | -10 to +55°C (No Freezing Or Condensation) | |
When Stored | -25 to +65°C (No Freezing Or Condensation) | ||
Operating Humidity Range | When In Use | Relative Humidity 25 to 85% (No Condensation) | |
Main Body Mass | Approx. 220 g |
Input Signal | Non-voltage contact (30 Hz max. ON/OFF pulse width 15 ms or more) Voltage pulse (5 kHz max. ON/OFF pulse width 90 μs or more, ON voltage: 4.5 to 30 V / OFF voltage: 0 to 2 V, input impedance: 10 kΩ) Open collector (5 kHz max. ON/OFF pulse width 90 μs or more) |
---|---|
Measurement Accuracy (at 23±5°C) | ±0.1% FS ±1 digit or less |
Measurement Method | Periodic Measurement Method |
Connectible Sensor | Residual voltage when ON: 2.5 V or less Leak current when OFF: 0.1 mA or less Load current: Must have an opening/closing capacity of 15 mA or more, and secure switching of a load current of 5 mA or less must be possible |
Maximum Number Of Display Digits | 5 Digits (-19,999 to 99,999) |
Display | 7-Segment Digital Display |
Polarity Display | "-" is automatically displayed when the input signal is negative |
Zero Display | Upper Digit Zero Suppression |
Scaling Function | Program method (display range conforms to the maximum display digit) Decimal position can be set as desired |
Hold Function | MAX Value Hold, MIN Value Hold |
Comparison Output Hysteresis Setting | Program Method With Front Keys (0001 To 9999) |
Other Functions | Scaling teach function Display color switching (green [red] / green / red [green] / red) Comparison type switching (upper limit / lower limit / upper and lower limit) Averaging processing function (simple average OFF/2/4/8 times) Auto zero time, start-up compensation timer, setting change protection function, set value initialization, display automatic recovery time |
Output Format | Relay contact output (2a output) |
Comparison Output Answer Time | 750 ms or less |
Protective Structure | Front: NEMA4X compliant for indoors (IP66 equivalent) Rear case: IP20 Terminal: IP00 + finger protection (VDE0106/100) (when terminal cover is installed) |
Memory Protection | Non-volatile memory (number of writes: 100,000 times) |
Refer to the catalog for product information not listed above.
Part Number |
---|
K3MA-F-A2 AC100-240 |
K3MA-F-A2 AC/DC24 |
K3MA-F AC100-240 |
K3MA-F AC/DC24 |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | Output Type | Number of Outputs | Power Supply Voltage (V) |
---|---|---|---|---|---|---|---|---|
฿ 9,728.00 ฿ 7,296.00 | OMRPANELMETER | 1 Piece(s) | Same day | Relay contact output (1a) | 2 | AC 100–240 | ||
฿ 9,342.00 ฿ 7,473.60 | PANELMETER | 1 Piece(s) | 45 Day(s) | Relay contact output (1a) | 2 | AC/DC24 | ||
฿ 10,213.00 ฿ 5,425.15 | PANELMETER | 1 Piece(s) | Same day | NA | - | AC 100–240 | ||
฿ 10,215.00 ฿ 8,172.00 | OMRPANELMETER | 1 Piece(s) | 50 Day(s) | NA | - | AC/DC24 |
Loading...
Mounting Method | Panel Mount | Panel cut dimensions | 92x45 | Standard | CE / UL / CSA |
---|---|---|---|---|---|
Dimension length(mm) | 48 | Dimension width(mm) | 96 | Dimension thickness(mm) | 80 |
Input Type | NPN/voltage pulse/PNP | Communication Type | NA | Calculation function | Scaling |
Display Digits | 5 digits | MAX measurement speed | Maximum 5kHz | Protective structure (front) | NEMA4X (corresponding to IP66) |