Mini Relay G5V-2

Caution
Product Description
2-pole signal relay.
[Features]
· Features a wide contact switching range of 10 μA to 2 A.
· A plastic sealed type. Equipped as standard with crossbar twin contacts.· High environmental resistance and high reliability.
· FCC Part 68 (1,500 V for 10 × 160 μs) compliant for between coil-contacts and between contacts of the same pole.
· High withstand voltage of 1,000 V AC between coil-contacts and 750 V AC between contacts of the same pole.
· Conforms to UL and CSA standards.
[Applications]
· Used for a broad range of applications including security devices and data communications equipment, such as those in telephone exchanges.
Dimensional Drawing of OMRON Signal Relays

Signal Relays Model G5V-2 external appearance

Signal Relays Model G5V-2 dimensional outline drawing
- *Average dimensions.

Signal Relays PCB processing dimensions
The dimensional tolerance is ±0.1 mm.

Signal Relays Terminal layout/schematics
There is no coil polarity.
Specification Table of OMRON Signal Relays
■ OMRON Signal Relays Ratings, Operational Coil
| Class- ification | Items Rated Voltage (V) | Rated Current (mA) | Coil Resistance (Ω) | Operating Voltage (V) | Release Voltage (V) | Maximum Allowable Voltage (V) | Power Consumption (mW) | |
|---|---|---|---|---|---|---|---|---|
| Stan- dard Type | DC | 3 | 166.7 | 18 | 75% or Less | 5% or More | 120% (at 23°C) | Approx. 500 |
| 5 | 100 | 50 | ||||||
| 6 | 83.3 | 72 | ||||||
| 9 | 55.6 | 162 | ||||||
| 12 | 41.7 | 288 | ||||||
| 24 | 20.8 | 1,152 | ||||||
| 48 | 12 | 4,000 | Approx. 580 | |||||
| Ultra- High- Sensi- tivity Type | DC | 5 | 30 | 166.7 | 75% or Less | 5% or More | 180% (at 23°C) | Approx. 150 |
| 12 | 12.5 | 960 | ||||||
| 24 | 8.33 | 2,880 | Approx. 200 | |||||
| 48 | 6.25 | 7,680 | 150% (at 23°C) | Approx. 300 | ||||
Note 1 : Signal Relays, The rated current and coil resistance are measured at a coil temperature of +23°C and atolerance of 10%.
Note 2 : Signal Relays, The operating characteristics are measured at a coil temperature of +23°C.
Note 3 : Signal Relays, The maximum allowable voltage is the maximum voltage that can be applied to a relay coil.
■ OMRON Signal Relays Switching Part (Contact Part)
| Items | Classification Load | Standard Type | Ultra-High-Sensitivity Type |
|---|---|---|---|
| Resistance Load | |||
| Contact Touching Mechanism | Crossbar Twin Contacts | ||
| Contact Material | Au Alloy + Ag | ||
| Rated Load | 125 V AC 0.5 A, 30 V DC 2 A | 125 V AC 0.5 A, 24 V DC 1 A | |
| Rated Conduction Current | 2 A | ||
| Maximum Contact Voltage Value | 125 V AC, 125 V DC | ||
| Maximum Contact Current Value | 2 A | 1 A | |
■ OMRON Signal Relays Performance
| Items | Classification | Standard Type | Ultra-High-Sensitivity Type |
|---|---|---|---|
| Contact Resistance *1 | 50 mΩ or Less | 100 mΩ or Less | |
| Turn-ON Time | 7 ms or Less | ||
| Turn-OFF Time | 3 ms or Less | ||
| Insulation Resistance *2 | 1,000 MΩ or More (500 V DC Megohmmeter) | ||
| Withstand Voltage | Between Coil and Contact | 1,000 V AC 50/60 Hz 1 min | |
| Between Contacts of Same Polarity | 750 V AC 50/60 Hz 1 min | 500 V AC, 50/60 Hz, 1 min | |
| Between Contacts of Different Polarities | 1,000 V AC 50/60 Hz 1 min | ||
| Vibration | Durability | 10 to 55 to 10 Hz, Semi Amplitude 0.75 mm (Double Amplitude1.5 mm) | |
| Malfunction | 10 to 55 to 10 Hz, Semi Amplitude 0.75 mm (Double Amplitude1.5 mm) | ||
| Shock / Impact | Durability | 1,000 m/s2 | |
| Malfunction | 200 m/s2 | 100 m/s2 | |
| Durability | Mechanical | 15,000,000 Times or More (Switching Frequency: 36,000 Times/h) | |
| Electrical | 100,000 Times or More (Switching Frequency: 1,800 Times/h) | AC 100,000 Times or More, DC 300,000 Times or More (Switching Frequency: 1,800Times/h) | |
| Failure Rate P Level (Reference Value *3) | DC 10 mV 10 μA | ||
| Ambient Operating Temperature | -25 to +65°C (Assuming No Freezing or Condensation) | -25 to +70°C (Assuming No Freezing or Condensation) | |
| Operating Ambient Humidity | 5 to 85% RH | ||
| Weight | Approx. 5 g | ||
Note: The above values are the initial default values.
*1. Signal Relays, Measurement conditions: 1 V DC 10 mA, voltage drop method.
*2. Signal Relays, Measurement conditions: Measuring the same spot for the withstand voltage items using a500 V DC insulation resistance meter.
*3. Signal Relays, This value is obtained with a switching frequency of 120 times/min. and a contact resistancefailure value of 50 Ω.
These values of Signal Relays may vary depending on switching frequency and operating conditions, meaning it is alwaysrecommended to double-check under actual load conditions.