Surface-mount Relay - G6S

Caution
Product Description
A small 2-pole, 2 A class signal switching type signal relay.
[Features]
· A surface mountable 2-pole relay for signal switching with which the terminal protrudes from the side.
· The use of heat-resistant materials supports IRS mounting methods.
· The standard type complies with UL and CSA standards.
· The series now includes terminal types for PCBs (model G65-2).
· EN60950 certified types are also available (-Y type.)
[Applications]
· Useful for a broad range of applications. Simply mount onto the PCB of communications equipment, OA devices, etc.
G6S-2/G6S-2-Y Specifications

G6S-2/G6S-2-Y external appearance

G6S-2/G6S-2-Y dimensional outline drawing
Units: mm
The general dimensional tolerance is ±0.3 mm.

PCB processing dimensions
Units: mm
The general dimensional tolerance is 0.3 mm.
G6SK-2 Specifications

G6SK-2 external appearance

G6SK-2 dimensional outline drawing
Units: mm
The general dimensional tolerance is ±0.3 mm.

PCB processing dimensions
Units: mm
The general dimensional tolerance is 0.3 mm.
G6SU-2 Specifications

G6SU-2 external appearance

G6SU-2 dimensional outline drawing
Units: mm
The general dimensional tolerance is ±0.3 mm.

PCB processing dimensions
Units: mm
The general dimensional tolerance is ±0.3 mm.
Ratings
Operating Coil / Single Stable Type
| Classification | Items | Rated Current (mA) | Coil Resistance (Ω) | Operating Voltage (V) | Release Voltage (V) | Maximum Allowable Voltage (V) | Power Consumption (mW) | |
|---|---|---|---|---|---|---|---|---|
| Rated Voltage (V) | ||||||||
| Model G6S-2 | DC | 4.5 | 31 | 145 | 75% or Less | 10% or More | 200% (23°C) | Approx. 140 |
| 5 | 28.1 | 178 | ||||||
| 12 | 11.7 | 1,028 | ||||||
| 24 | 8.3 | 2,880 | 170% (23°C) | Approx. 200 | ||||
| Model G6S-2-Y | DC | 12 | 16.7 | 720 | 75% or Less | 10% or More | 170% (23°C) | Approx. 200 |
| 24 | 9.6 | 2,504 | Approx. 230 | |||||
- *1: The rated current and coil resistance are measured at a coil temperature of 23°C and a tolerance of ±10%.
- *2: The operating characteristics are measured at a coil temperature of 23°C.
- *3: The maximum allowable voltage is the maximum voltage that can be applied to a relay coil.
Operating Coil / Dual Coil Latching Type
| Classification | Items | Rated Current (mA) | Coil Resistance (Ω) | Set Voltage (V) | Reset Voltage (V) | Maximum Allowable Voltage (V) | Power Consumption (mW) | |
|---|---|---|---|---|---|---|---|---|
| Rated Voltage (V) | ||||||||
| Model G6SK-2 | DC | 5 | 40 | 125 | 75% or Less | 75% or Less | 170% (23°C) | Approx. 200 |
| 12 | 16.7 | 720 | ||||||
- *1: The rated current and coil resistance are measured at a coil temperature of 23°C and a tolerance of ±10%.
- *2: The operating characteristics are measured at a coil temperature of 23°C.
- *3: The maximum allowable voltage is the maximum voltage that can be applied to a relay coil.
Operating Coil / Single Coil Latching Type
| Classification | Items | Rated Current (mA) | Coil Resistance (Ω) | Set Voltage (V) | Reset Voltage (V) | Maximum Allowable Voltage (V) | Power Consumption (mW) | |
|---|---|---|---|---|---|---|---|---|
| Rated Voltage (V) | ||||||||
| Model G6SU-2 | DC | 3 | 33.3 | 90 | 75% or Less | 75% or Less | 180% (23°C) | Approx. 100 |
- *1: The rated current and coil resistance are measured at a coil temperature of 23°C and a tolerance of ±10%.
- *2: The operating characteristics are measured at a coil temperature of 23°C.
- *3: The maximum allowable voltage is the maximum voltage that can be applied to a relay coil.
Switching Part (Contact Part)
| Load | Resistance Load |
|---|---|
| Rated Load | 125 V AC 0.5 A, 30 V DC 2 A |
| Rated Conduction Current | 2 A |
| Maximum Contact Voltage Value | 250 V AC, 220 V DC |
| Maximum Contact Current Value | 2 A |
Performance
| Type | Single Stable Type Model G6S-2 | Single Coil Latching Type Model G6SU-2 | Dual Coil Latching Type Model G6SK-2 | Single Stable Type Model G6S-2-Y | |
|---|---|---|---|---|---|
| Contact Resistance *1 | 75 mΩ or Less | ||||
| Operation (Set) Time *2 | 4 ms or Less (Approx. 2.5 ms) | 4 ms or Less (Approx. 2 ms) | 4 ms or Less (Approx. 2.5 ms) | ||
| Recovery (Reset) Time *2 | 4 ms or Less (Approx. 1.5 ms) | 4 ms or Less (Approx. 2 ms) | 4 ms or Less (Approx. 1.5 ms) | ||
| Minimum Set/Reset Pulse Width | - | 10 ms | - | ||
| Insulation Resistance *3 | 1,000 MΩ or More (with 500 V DC Megohmmeter) | ||||
| Withstand Voltage | Between Coil and Contact | 2,000 V AC 50/60 Hz 1 min | 1,000 V AC 50/60 Hz 1 min | 2,000 V AC 50/60 Hz 1 min | |
| Between Contacts of Different Polarities | 1,500 V AC 50/60 Hz 1 min | ||||
| Between Contacts of Same Polarity | 1,000 V AC 50/60 Hz 1 min | ||||
| Between Set/Reset Coils | - | 500 V AC 50/60 Hz 1 min | - | ||
| Insulation Distance | Between Coil and Contact | Space: 1 mm, Creepage: 1.5 mm | Space: 2 mm, Creepage: 2 mm | ||
| Impulse Withstand Voltage | Between Coil and Contact | 2,500 V 2 ×10 μs, 1,500 V 10 × 160 μs | 1,500 V 10 × 160 μs | 2,500 V 2 ×10 μs, 1,500 V 10 × 160 μs | |
| Between Contacts of Different Polarities | 2,500 V 2 × 10 μs, 1,500 V 10 × 160 μs | ||||
| Between Contacts of Same Polarity | 1,500 V 10 × 160 μs | ||||
| Vibration | Durability | 10 to 55 to 10 Hz, Semi Amplitude 2.5 mm (Double Amplitude 5 mm) | |||
| Malfunction | 10 to 55 to 10 Hz, Semi Amplitude 1.65 mm (Double Amplitude 3.3 mm) | ||||
| Shock / Impact | Durability | 1,000 m/s2 | |||
| Malfunction | 750 m/s2 | ||||
| Durability | Mechanical | 100,000,000 Times or More (Switching Frequency: 36,000 Times/h) | |||
| Electrical | AC 100,000 Times or More (Rated Load, Switching Frequency: 1,800 Times/h) DC 100,000 Times or More (Rated Load, Switching Frequency: 1,200 Times/h) | ||||
| Failure Rate P Level (Reference Value *4) | DC 10 mV 10 μA | ||||
| Ambient Operating Temperature | -40 to +85°C (Assuming No Freezing or Condensation), Dual Coil Latching Type 24 V DC Specification and Y Type 24 V DC Specification Only -40 to +70°C (Assuming No Freezing or Condensation) | ||||
| Operating Ambient Humidity | 5 to 85%RH | ||||
| Weight | Approx. 2 g | ||||
- *The above values are the initial default values.
*1. Measurement conditions: 1 V DC, 10 mA, voltage drop method.
*2. The values within ( ) are the actual values.
*3. Measurement conditions: Measuring the same spot for the withstand voltage items using a 500 V DC insulation resistance meter. (Except between set and reset coils)
*4 This value is obtained with a switching frequency of 120 times/min. and a contact resistance failure value of 50 Ω. These values may vary depending on switching frequency and operating conditions, meaning it is always recommended to double-check under actual load conditions.
Common Items
- Features a long terminal shape and soldered parts that are highly reliable over long periods (surface mounted terminal type).
- An internal L-type terminal that allows for high-density mounting (surface mounted terminal type).
- The temperature of the terminal easily increases, ensuring good soldering properties (surface mounted terminal type).
- Features a high withstand voltage between coil-contacts of 2,000 V AC. Also features a high impulse withstand voltage of 2,500 V, 2 × 10 μs (Telcordia standard.)
- Achieves a high-sensitivity rated power consumption of 140 mW.
- *Refer to the catalog for product information other than that above.