DC Power Relay (60 A and 100 A Type) G9EA-1

Caution
Product Description
DC power relay capable of interrupting high voltage high current DC loads.
[Features]
· The contacts are not affected by the ambient atmosphere and so ensure high contact reliability.
· No limitations to mounting direction due to parts miniaturization and appropriate matching design.
· Terminal cover and DIN track adapters are also available for general industrial applications.
· UL/CSA standard UL508 approved.
· [Applications]
· For interrupting high voltage, high current DC loads.
DC Power Relay Specifications

G9EA-1 external appearance
- A compact relay (67.2 × 36 × 73 mm [H × W × L]) capable of 400-V DC 60-A switching. (Capable of interrupting 600 A at 300 V DC max.)
- The switching section and driving section are gas-injected and hermetically sealed, allowing these compact relays to interrupt high-capacity loads. Also requires no arc space, saves space, and helps ensure safe applications. Also provides high contact reliability with contacts that are not affected by the surrounding atmosphere.
DC Power Relay Performance
| Format | Model G9EA-1(-B) | Model G9EA-1(-B)-CA | |
|---|---|---|---|
| Contact Resistance *1 | 30 mΩ max. (Typ. 0.6 mΩ) | 10 mΩ max. (Typ. 0.3 mΩ) | |
| Contact Voltage Drop | 0.1 V max. (for a carry current of 60 A) | 0.1 V max. (for a carry current of 100 A) | |
| Operating Time | 50 ms max. | ||
| Release Time | 30 ms max. | ||
| Insulation Resistance *2 | Between Coil and Contacts | 1,000 MΩ min. | |
| Between Contacts of Same Polarity | 1,000 MΩ min. | ||
| Dielectric Strength | Between Coil and Contacts | 2,500 V AC for 1 min | |
| Between Contacts of Same Polarity | 2,500 V AC for 1 min | ||
| Impulse Withstand Voltage *3 | 4,500 V | ||
| Vibration Resistance | Durability | 10 to 55 to 10 Hz, 0.75-mm single amplitude (Acceleration: 2.94 to 88.9 m/s2) | |
| Malfunction | 10 to 55 to 10 Hz, 0.75-mm single amplitude (Acceleration: 2.94 to 88.9 m/s2) | ||
| Shock Resistance | Durability | 490 m/s2 | |
| Malfunction | 196 m/s2 | ||
| Mechanical Durability *4 | 200,000 operations min. | ||
| Electrical Durability (Resistive Load) *5 | 120 V DC 100 A 3,000 operations min. | 400 V DC 30 A 1,000 operations min. | |
| 400 V DC 60 A 3,000 operations min. | 120 V DC 30 A 2,500 operations min. | ||
| 400 V DC 30 A 30,000 operations min. | -- | ||
| Short-Time Carry Current | 100 A (10 mins) | 150 A (10 mins) | |
| Maximum Interruption Current | 300 V DC 600 A (5 times) | -- | |
| Overload Interruption | 400 V DC 180 A (100 times min.) | 120 V DC 100 A (150 times min.) | |
| Reverse Polarity Interruption | 200 V DC - 60 A (1,000 times min.) | -- | |
| Ambient Operating Temperature | -40 to +70°C (assuming no icing or condensation) | ||
| Ambient Operating Humidity | 5 to 85% RH | ||
| Weight (Including Accessories) | Approx. 310 g | ||
Note: The above values are initial values at an ambient temperature of 23°C unless otherwise specified.
*1. Measurement conditions: 5 V DC, 1 A, voltage drop method.
*2. Measurement conditions: measured with a megohmmeter (500 V DC).
*3. Measured with a JEC-212 (1981) standard impulse voltage waveform (1.2 × 50 µs).
*4. Test conditions: switching frequency: 3,600 operations/hr
*5. Test conditions: switching frequency: 60 operations/hr
DC Power Relay External Shape and Dimensional Drawing

Screw terminal type Model G9EA-1-B(-CA) external shape

Screw terminal type Model G9EA-1-B(-CA) dimensional drawing

Mounting hole machining dimensions
- *See the catalog for external shapes and dimensional drawings for model numbers other than those detailed above.