GOT1000 CC-Link Communication Unit

Brand :
MITSUBISHI

Caution

  • This product belongs in RoHS Directive under Category 9 "Monitoring and control equipment" with exclusion from the usage restriction of phthalate esters until 21 July 2021.

Product Description

CC-Link Communication Unit for GOT1000 Series.
[Features]
・ Intelligent device station module CC-Link Ver.2 compatible
・ Number of occupied stations 1 station/4 stations selectable

GOT1000 CC-Link Communication Unit Details

Product image of GT15-J61BT13

Product image of GT15-J61BT13

Dimensional Drawing of the Product

 

(Unit: mm)

 

GT15-J61BT13 dimensional drawing

GT15-J61BT13 dimensional drawing

Product Specifications

CategoryCommunication unit
SeriesGOT1000
UnitCC-Link Communication Unit
Product Type NameGT15-J61BT13
Applicable StandardsUL/cUL, CE(EMC), KC
Supported ModelsGT27, GT25 (5.7 type, wide model, enhanced environmental resistance model are excluded), GT16, GT15
CC-Link Station TypeIntelligent Device Station
Number of Occupied StationsPossible to select 1 or 4 stations
Ver. 1 ModeMaximum Link Points Per SystemRemote inputs/outputs (RX, RY): 2,048 points, Remote registers (RWw): 256 points, Remote registers (RWr): 256 points
Link Points Per StationRemote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 4 points, Remote registers (RWr): 4 points
Number of Link Points Per Number of Occupied Stations"One station occupied" Remote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 4 points, Remote registers (RWr): 4 points,
"4 stations occupied" Remote inputs/outputs (RX, RY): 128 points, Remote registers (RWw): 16 points, Remote registers (RWr): 16 points
Ver. 2 ModeMaximum Link Points Per SystemRemote inputs/outputs (RX, RY): 8,192 points, Remote registers (RWw): 2,048 points, Remote registers (RWr): 2,048 points
Link Points Per StationExpanded Cyclic Setting: × 1 SettingRemote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 4 points, Remote registers (RWr): 4 points
Expanded Cyclic Setting: × 2 SettingRemote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 8 points, Remote registers (RWr): 8 points
Expanded Cyclic Setting: × 4 SettingRemote inputs/outputs (RX, RY): 64 points, Remote registers (RWw): 16 points, Remote registers (RWr): 16 points
Expanded Cyclic Setting: × 8 SettingRemote inputs/outputs (RX, RY): 128 points, Remote registers (RWw): 32 points, Remote registers (RWr): 32 points
Number of Link Points Per Number of Occupied StationsExpanded Cyclic Setting: × 1 Setting"One station occupied" Remote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 4 points, Remote registers (RWr): 4 points,
"4 stations occupied" Remote inputs/outputs (RX, RY): 128 points, Remote registers (RWw): 16 points, Remote registers (RWr): 16 points
Expanded Cyclic Setting: × 2 Setting"One station occupied" Remote inputs/outputs (RX, RY): 32 points, Remote registers (RWw): 8 points, Remote registers (RWr): 8 points,
"4 stations occupied" Remote inputs/outputs (RX, RY): 224 points, Remote registers (RWw): 32 points, Remote registers (RWr): 32 points
Expanded Cyclic Setting: × 4 Setting"One station occupied" Remote inputs/outputs (RX, RY): 64 points, Remote registers (RWw): 16 points, Remote registers (RWr): 16 points,
"4 stations occupied" Remote inputs/outputs (RX, RY): 448 points, Remote registers (RWw): 64 points, Remote registers (RWr): 64 points
Expanded Cyclic Setting: × 8 Setting"One station occupied" Remote inputs/outputs (RX, RY): 128 points, Remote registers (RWw): 32 points, Remote registers (RWr): 32 points,
"4 stations occupied" Remote inputs/outputs (RX, RY): 896 points, Remote registers (RWw): 128 points, Remote registers (RWr): 128 points
Transmission Speed156 kbps / 625 kbps / 2.5 Mbps / 5 Mbps / 10 Mbps
Maximum Transmission DistanceVaries depending on the transmission speed.
Maximum Number of Connected Devices26 devices Maximum number of connected devices varies depending on the CC-Link system configuration used. For details of maximum number of connected devices, refer to CC-Link user’s manual (detailed version).
Connection CableCC-Link dedicated cable
Internal Current Consumption (5 V DC)0.56 A
Weight0.18 kg
Terminal BlockScrew Tightening TorqueScrew for wiring: 0.5 to 0.6 N·m
Terminal block mounting screw: 0.7 to 0.8 N·m
Recommended DriverrStraight slot screwdriver (blade point thickness: 0.6 mm, width 3.5 mm)
  • *When mounting an expansion unit on the CC-Link Communication Unit, the ambient temperature for general specifications should be 5°C lower than the maximum temperature.
  • *Remote input/output with the maximum link points per system: Input/output signals (RX, RY) occupy 16 points of system area within each device point.
Viewed Products
Recently Viewed Products
My Components
My Components
0
Cart
Cart
Economy Series
MRO Product

Chat with MISUMI

Chat service is available for any inquiry to MISUMI

Service hours

9:00 - 18:00 (Mon-Sat)

For out of service hours, you can leave a message to us.
We will reply to your inquiries on the next business day.
(except Sundays and public holidays).

Noted for use

Chat service is for Corporate customers and limited for Thai language.

Request for Quotation and Place Order is not available on Chat.

Start chat