GOT1000 External Input/Output Unit

Brand :
MITSUBISHI

Caution

  • This product belongs in RoHS Directive under Category 9 "Monitoring and control equipment" with exclusion from the usage restriction of phthalate esters until 21 July 2021.

Product Description

Mitsubishi GOT1000 External Input/Output Unit.
[Features]
·For the GOT1000 series.
[Applications]
·Used as an external input/output unit.

GOT1000 External Input/Output Unit Specifications

Product image of GOT1000 External Input/Output Unit

Product image of GOT1000 External Input/Output Unit

Specifications

 

(Unit: mm)

 

GT15-DIO dimensional drawing

GT15-DIO dimensional drawing

GT15-DIO Specifications

CategoryOptional unit
SeriesGOT1000
UnitExternal input/output unit
Product Type NameGT15-DIO
Applicable StandardsUL/cUL, CE(EMC), KC, ABS, BV, DNV GL, LR, NK, RINA
Supported ModelsGT27, GT25 (5.7 type, wide model, enhanced environmental resistance model, Handy GOT are excluded), GT16, GT15
Common SpecificationsExternal Connection Method50-pin connector
Compatible Wire SizeAWG#28 or less
Operation DisplayN/A
External Power SupplyVoltage24 V DC (+20%/-15%, ripple ratio within 5%)
Current1.85 A
Dielectric Strength350 V AC for 1 minute
Internal Current Consumption0.10 A
Weight0.13 kg
Input Specifications (Source Type)Input MethodDynamic scan method
Number of Inputs16 points / 128 points (16 × 8) (Output 8 points for scan)
Insulation MethodOpto-isolator insulation
Rated Input Voltage24 V DC (+20%/-15%, ripple ratio within 5%)
Rated Input CurrentApprox. 4 mA
Input Derating(External input/output unit [Positive common input / Sink type output] [for GOT2000 Series/GOT1000 Series] Refer to Instruction Manual.)
ON Voltage / ON Current15 V DC or more / 2 mA or more
OFF Voltage / OFF Current4 V DC or less / 1 mA or less
Input ResistanceApprox. 5.6 KΩ
Response TimeON → OFF0.4 ms or less (24 V DC)
OFF → ON0.4 ms or less (24 V DC)
Common Method16 points 1 common (common terminal: 0 V (Pin number 26 to 29))
Dynamic Scan Cycle13.3 ms
Output Specifications (Sink Type)Output MethodDirect output
Number of Outputs16 points + 1 point (RUN output)
Insulation MethodOpto-isolator insulation
Rated Load Voltage24 V DC (+20%/-15%)
Max Load Current0.1 A / 1 point
Maximum Inrush Current0.7 A 10 ms or less
Leakage Current When OFF0.1 mA or less
Maximum Voltage Drop When ON0.2 V DC (Max.) 0.1 A
Protection FunctionAvailable (Overload protection function, overheat protection function)
Response TimeON → OFF1 ms or less (resistant load)
OFF → ON1 ms or less
Common Method16 points 1 common (common terminal: 24 V (Pin number 1 to 4))
Surge SuppressorZener diode

Restrictions

  • External power supply voltage: When the external power supply is cut off, a system alarm is generated.
  • ON voltage / ON current, OFF voltage / OFF current: EN61131-2:2003 (digital input type 1) compatible
  • Response Time: Time consumed in I/O part.
  • Number of Outputs Points: RUN output ON: During normal operation / OFF: WDT error in GOT main body
  • Protection function: A function to protect the internal elements of unit. It does not exist in RUN output. This is not a function to protect external devices. Automatically recovers when it is no longer overloaded or overheated. Overload protection function operates independently for each point with 1 to 3 A / 1 point. Overheat Protection Function operates independently for each point.

GT15-DIOR Specifications

CategoryOptional unit
SeriesGOT1000
UnitExternal input/output unit
Product Type NameGT15-DIOR
Applicable StandardsUL/cUL, CE(EMC), KC, ABS, BV, DNV GL, LR, NK, RINA
Supported ModelsGT27, GT25 (5.7 type, wide model, enhanced environmental resistance model, Handy GOT are excluded), GT16, GT15
Common SpecificationsExternal Connection Method50-pin connector
Compatible Wire SizeAWG#28 or less
Operation DisplayN/A
External Power SupplyVoltage24 V DC (+20%/-15%, ripple ratio within 5%)
Current1.85 A
Dielectric Strength350 V AC for 1 minute
Internal Current Consumption0.10 A
Weight0.13 kg
Input Specifications (Sink Type)Input MethodDynamic scan method
Number of Inputs16 points / 128 points (16 × 8) (Output 8 points for scan)
Insulation MethodOpto-isolator insulation
Rated Input Voltage24 V DC (+20%/-15%, ripple ratio within 5%)
Rated Input CurrentApprox. 4 mA
Input Derating(External input/output unit [Negative common input / Source type output] [for GOT2000 Series/GOT1000 Series] refer to instruction manual.)
ON Voltage / ON Current15 V DC or more / 2 mA or more
OFF Voltage / OFF Current4 V DC or less / 1 mA or less
Input ResistanceApprox. 5.6 KΩ
Response TimeON → OFF0.4 ms or less (24 V DC)
OFF → ON0.4 ms or less (24 V DC)
Common Method16 points 1 common (common terminal: 0 V (Pin number 26 to 29))
Dynamic Scan Cycle13.3 ms
Output Specifications (Source Type)Output MethodDirect output
Number of Outputs16 points + 1 point (RUN output)
Insulation MethodOpto-isolator insulation
Rated Load Voltage24 V DC (+20%/-15%)
Max Load Current0.1 A / 1 point
Maximum Inrush Current0.7 A 10 ms or less
Leakage Current When OFF0.1 mA or less
Maximum Voltage Drop When ON0.2 V DC (Max.) 0.1 A
Protection FunctionAvailable (Overload protection function, overheat protection function)
Response TimeON → OFF1 ms or less (resistant load)
OFF → ON1 ms or less
Common Method16 points 1 common (common terminal: 24 V (Pin number 1 to 4))
Surge SuppressorZener diode

Restrictions

  • External power supply voltage: When the external power supply is cut off, a system alarm is generated.
  • ON voltage / ON current, OFF voltage / OFF current: EN61131-2:2003 (digital input type 1) compatible
  • Response Time: Time consumed in I/O part.
  • Number of Outputs Points: RUN output ON: During normal operation / OFF: WDT error in GOT main body
  • Protection function: A function to protect the internal elements of unit. It does not exist in RUN output. This is not a function to protect external devices. Automatically recovers when it is no longer overloaded or overheated. Overload protection function operates independently for each point with 1 to 3 A / 1 point. Overheat Protection Function operates for each 2 points (with a combination of YD00/YD01 to YD0E/YD0F).
Viewed Products
Recently Viewed Products
My Components
My Components
0
Cart
Cart
Economy Series
MRO Product

Chat with MISUMI

Chat service is available for any inquiry to MISUMI

Service hours

9:00 - 18:00 (Mon-Sat)

For out of service hours, you can leave a message to us.
We will reply to your inquiries on the next business day.
(except Sundays and public holidays).

Noted for use

Chat service is for Corporate customers and limited for Thai language.

Request for Quotation and Place Order is not available on Chat.

Start chat

GT15-DIOR | GOT1000 External Input/Output Unit | MITSUBISHI | MISUMI Thailand