(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.
Select part number to Order Now/ Add to Cart
Inverter integrated with the power regeneration function for an easy panel design.
[Features]
· Built-in power regeneration function to achieve great braking capability.
· Various advanced technologies packed into a compact body.
· High-performance inverter that is optimal for ascending and descending operations or line control.
· Help improve performance of machinery and equipment that generate regenerative torque, such as elevating machines, centrifuge separators, various testers and winders.
[Applications]
· Ideal for frequency control.
FREQROL-A701 Series external appearance
Application examples (multi-story parking)
Application examples (ceiling crane)
200 V class
Model Name FR-A721-□□K | 5.5 | 7.5 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | |
---|---|---|---|---|---|---|---|---|---|---|
Applicable Motor Capacity (kW)*1 | 5.5 | 7.5 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | |
Output | Rated Capacity (kVA)*2 | 9.2 | 12.6 | 23.3 | 29 | 34 | 44 | 55 | 67 | 82 |
Rated Current (A) | 24 | 33 | 61 | 76 | 90 | 115 | 145 | 175 | 215 | |
Overload Current Rating*3 | 150% for 60 sec, 200% for 3 sec (inverse time characteristics), ambient temperature 50°C | |||||||||
Rated Voltage*4 | 3‑phase 200 to 240 V | |||||||||
Regenerative Braking Torque | 100% continuous, 150% for 60 sec | |||||||||
Power Supply | Rated Input AC Voltage / Frequency | 3‑phase 200 to 220 V / 50 Hz, 200 to 240 V / 60 Hz | ||||||||
Allowable AC Voltage Variation | 170 to 242 V 50 Hz, 170 to 264 V 60 Hz | |||||||||
Allowable Frequency Variation | ±5% | |||||||||
Power Supply Facility Capacity (kVA)*5 | 12 | 17 | 28 | 34 | 41 | 52 | 66 | 80 | 100 | |
Protective Structure (JEM 1030)*6 | Open Model (IP00) | |||||||||
Cooling Method | Forced Air Cooling | |||||||||
Approx. Mass (kg) | 20 | 22 | 35 | 50 | 52 | 69 | 87 | 90 | 120 |
400 V class
Model Name FR-A741-□□K | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | |
---|---|---|---|---|---|---|---|---|---|---|---|
Applicable Motor Capacity (kW)*1 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | |
Output | Rated Capacity (kVA)*2 | 9.1 | 13 | 17.5 | 23.6 | 29 | 32.8 | 43.4 | 54 | 65 | 84 |
Rated Current (A) | 12 | 17 | 23 | 31 | 38 | 44 | 57 | 71 | 86 | 110 | |
Overload Current Rating*3 | 150% for 60 sec, 200% for 3 sec (inverse time characteristics), ambient temperature 50°C | ||||||||||
Rated Voltage*4 | 3‑phase 380 to 480 V | ||||||||||
Regenerative Braking Torque | 100% continuous, 150% for 60 sec | ||||||||||
Power Supply | Rated Input AC Voltage / Frequency | 3‑phase 380 to 480 V, 50 Hz / 60 Hz | |||||||||
Allowable AC Voltage Variation | 323 to 528 V, 50 Hz / 60 Hz | ||||||||||
Allowable Frequency Variation | ±5% | ||||||||||
Power Supply Facility Capacity (kVA)*5 | 12 | 17 | 20 | 28 | 34 | 41 | 52 | 66 | 80 | 100 | |
Protective Structure (JEM 1030)*6 | Open Model (IP00) | ||||||||||
Cooling Method | Forced Air Cooling | ||||||||||
Approx. Mass (kg) | 25 | 26 | 37 | 40 | 48 | 49 | 65 | 80 | 83 | 115 |
FR-A721-5.5K, 7.5K / FR-A741-5.5K, 7.5K dimensional drawing
Inverter Model Name | D1 | D2 |
---|---|---|
FR-A721-5.5K, 7.5K | 163 | 90 |
FR-A741-5.5K, 7.5K | 168 | 85 |
FR-A721-15K / FR-A741-11K, 15K dimensional drawing
Inverter Model Name | D1 | D2 |
---|---|---|
FR-A721-15K | 213 | 64 |
FR-A741-11K, 15K | 224 | 53 |
FR-A721-18.5K, 22K / FR-A741-18.5K, 22K dimensional drawing
Inverter Model Name | D1 | D2 | W | W1 | W2 | W3 |
---|---|---|---|---|---|---|
FR-A721-18.5K, 22K | 219 | 84 | 390 | 290 | 345 | 370 |
FR-A741-18.5K, 22K | 238 | 65 | 360 | 260 | 315 | 340 |
FR-A721-30K / FR-A741-30K dimensional drawing
Inverter Model Name | D1 | D2 |
---|---|---|
FR-A721-30K | 240.5 | 82.5 |
FR-A741-30K | 252.5 | 70.5 |
FR-A721-37K, 45K / FR-A741-37K, 45K dimensional drawing
Inverter Model Name | D1 | D2 |
---|---|---|
FR-A721-37K, 45K | 257.5 | 93.5 |
FR-A741-37K, 45K | 281.5 | 69.5 |
FR-A721-55K/FR-A741-55K dimensional drawing
Inverter Model Name | D1 | D2 |
---|---|---|
FR-A721-55K | 312 | 76 |
FR-A741-55K | 324.5 | 64 |
*The information provided here is not comprehensive.
Part Number |
---|
FR-A741-15K |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | Applicable motor capacity (kW) | Input voltage class | Output capacity (kVA) | Representative Standard | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Output rated current (A) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 130,947.00 ฿ 87,302.36 | INVERTER | 1 Piece(s) | Quote | 15 | Three-phase 400V | 23.6 | CE / UL / CUL | 600 | 300 | 294 | 31 |
Loading...
Output Specification | Three-Phase | External communications | RS-232/422/485 | Protective Structure | Open model (IP00) |
---|
Please check the type/dimensions/specifications of the part FR-A741-15K in the Inverter FREQROL-A701 Series series.
Part Number |
---|
FR-A721-30K |
FR-A721-37K |
FR-A721-45K |
FR-A741-18.5K |
FR-A741-22K |
FR-A741-30K |
Part Number | Price | Minimum Order Qty | Volume Discount | Days to Ship | Applicable motor capacity (kW) | Input voltage class | Output capacity (kVA) | Representative Standard | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Output rated current (A) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 232,591.00 | 1 Piece(s) | Quote | 30 | Three-Phase 200 V | 44 | UL / CUL | 700 | 450 | 340 | 115 | ||
฿ 312,877.00 | 1 Piece(s) | Quote | 37 | Three-Phase 200 V | 55 | UL / CUL | 700 | 470 | 368 | 145 | ||
฿ 332,948.00 | 1 Piece(s) | Quote | 45 | Three-Phase 200 V | 67 | UL / CUL | 700 | 470 | 368 | 175 | ||
฿ 210,481.00 | 1 Piece(s) | Quote | 18.5 | Three-phase 400V | 29 | UL / CUL / CE | 600 | 360 | 320 | 38 | ||
฿ 224,219.00 | 1 Piece(s) | Quote | 22 | Three-phase 400V | 32.8 | UL / CUL / CE | 600 | 360 | 320 | 44 | ||
฿ 267,475.00 | 1 Piece(s) | Quote | 30 | Three-phase 400V | 43.4 | UL / CUL / CE | 700 | 450 | 340 | 57 |
How can we improve?