    Product Description

    Mitsubishi electromagnetic switch.
    [Features]
    · Simple current setting, manual check possible.
    [Applications]
    · Optimal for the overload and locking protection of a standard motor.

    MS-N Series Standard And 2-Element Thermal Relay Features

    • Can be used for standard motor overload and locking protection.
    • Motor current value can be directly set for easy setup.
    • *Adjust with a cross-head / straight-slot screwdriver.
    • Easy to change between manual reset and automatic reset.
    • Can use different voltages for a and b contacts.

    MS-N Series Standard And 2-Element Thermal Relay Specifications

    TH-N220HZ

    TypeThermal relay
    ProductOverload protection type thermal relay
    SeriesTH-N
    Type NameTH-N220HZ
    Number Of Elements2-element
    Settling Current Adjustment Range65 to 220 A
    Heater Nominal [A] Note 1(1)82 (65 to 100)
    105 (85 to 125)
    125 (100 to 150)
    150 (120 to 180)
    (2)180 (140 to 220)
    Power Consumption [VA/Element]
    Minimum/Maximum Settling Time
    1.0/2.3 Note 3
    Terminal Screw SizeM10
    Match To TerminalWire Size [mm2]-
    Crimp Terminal Size22-10 to 150-10
    Contact Configuration1a1b
    Open Thermocurrent lth (A)5
    Rated Operating Current [A]AC-15 Class (AC Electromagnetic Contactor Coil Switch) a-Contact / b-Contact - Note 224 V AC2 (0.5) / 3 (0.5)
    120 V AC2 (0.5) / 3 (0.5)
    240 V AC1 (0.5) / 2 (0.5)
    550 V AC0.5 (0.5) / 1 (0.5)
    DC-13 Class (DC Electromagnetic Contactor Coil Switch) a-Contact/b-Contact - Note 224 V DC1 (0.3)
    110 V DC0.2 (0.2)
    220 V DC0.1 (0.1)
    Minimum Applied Load Level20 V 5 mA
    Terminal Screw SizeM4
    Wire Size Matching TerminalWire Size [mm2]ø1.6, 1.25 to 2
    Crimp Terminal Size1.25 to 4 to 2-4, 5.5-S4
    Electromagnetic Contactor Frame To Combine - Note 1(1)N180, N220
    (2)N220
    Single-Unit MountingYes
    Terminal CoverStandard Terminal CoverN/A
    Wiring Streamlining Terminal FunctionN/A
    Usage ConditionsAmbient Temperature [°C]-10 to +40°C
    (standard is 20°C, maximum temperature in panel 55°C)
    Frequency [Hz]0 (DC) to 400
    Additional Functions/OptionsNo additional functions/options
    • Note 1: The electromagnetic contactor frame combination possibilities differ by the heater nominal (Example: Electromagnetic contactor (1) can be combined with heater nominal (1)).
    • Note 2: The values in ( ) are the rating upon automatic reset.
    • Note 3: Power consumption shows only consumption by the heater element (does not include current transformer consumption).

    TH-N400HZ

    TypeThermal relay
    ProductOverload protection type thermal relay
    SeriesTH-N
    Type NameTH-N400HZ
    Number Of Elements2-element
    Settling Current Adjustment Range85 to 400 A
    Heater Nominal [A] Note 1(1)105 (85 to 125)
    125 (100 to 150)
    150 (120 to 180)
    180 (140 to 220)
    250 (200 to 300)
    (2)330 (260 to 400)
    Note 3
    Power Consumption [VA/Element]
    Minimum/Maximum Settling Time
    1.0/2.3 Note 4
    Terminal Screw SizeM12
    Match To TerminalWire Size [mm2]-
    Crimp Terminal Size22-12 to 200-12
    Contact Configuration1a1b
    Open Thermocurrent lth (A)5
    Rated Operating Current [A]AC-15 Class (AC Electromagnetic Contactor Coil Switch) a-Contact / b-Contact - Note 224 V AC2 (0.5) / 3 (0.5)
    120 V AC2 (0.5) / 3 (0.5)
    240 V AC1 (0.5) / 2 (0.5)
    550 V AC0.5 (0.5) / 1 (0.5)
    DC-13 Class (DC Electromagnetic Contactor Coil Switch) a-Contact/b-Contact - Note 224 V DC1 (0.3)
    110 V DC0.2 (0.2)
    220 V DC0.1 (0.1)
    Minimum Applied Load Level20 V 5 mA
    Terminal Screw SizeM4
    Wire Size Matching TerminalWire Size [mm2]ø1.6, 1.25 to 2
    Crimp Terminal Size1.25 to 4 to 2-4, 5.5-S4
    Electromagnetic Contactor Frame To Combine - Note 1(1)N300, N400
    (2)N400
    Single-Unit MountingYes
    Terminal CoverStandard Terminal CoverN/A
    Wiring Streamlining Terminal FunctionN/A
    Usage ConditionsAmbient Temperature [°C]-10 to +40°C
    (standard is 20°C, maximum temperature in panel 55°C)
    Frequency [Hz]0 (DC) to 400
    Additional Functions/OptionsNo additional functions/options
    • Note 1: The electromagnetic contactor frame combination possibilities differ by the heater nominal (Example: Electromagnetic contactor ① can be combined with heater nominal ①.).
    • Note 2: The values in ( ) are the rating upon automatic reset.
    • Note 3: The thermal relay for heaters with nominal of 180 A or less are the same as the N220 frame.
    • Note 4: Power consumption shows only consumption by the heater element (does not include current transformer consumption).
    Viewed Products
    Recently Viewed Products
    My Components
    My Components
    0
    Cart
    Cart
    Economy Series
    MRO Product

    Chat with MISUMI

    Chat service is available for any inquiry to MISUMI

    Service hours

    9:00 - 18:00 (Mon-Sat)

    For out of service hours, you can leave a message to us.
    We will reply to your inquiries on the next business day.
    (except Sundays and public holidays).

    Noted for use

    Chat service is for Corporate customers and limited for Thai language.

    Request for Quotation and Place Order is not available on Chat.

    Start chat