Minimum width, low electrical power consumption and maximum flow control values: the solenoid valve CPE
[Features]
·Universal individual valve
·High flow rate relative to its size
[Materials]
·Housing: Die-cast aluminum
·Seals: NBR
Valve function | 3/2 | 5/2 | 5/3 | |||||
---|---|---|---|---|---|---|---|---|
Normal position | G | O | - | - | G | B | E | |
Stable position | Monostable | Bistable | Monostable | |||||
Reset method: pneumatic spring | Yes | - | No | |||||
Reset method: mechanical spring | No | - | Yes | |||||
Design | Piston spool | |||||||
Sealing principle | Soft | |||||||
Lap | Overlap | |||||||
Type of actuation | Electrical | |||||||
Type of control | Pilot | |||||||
Pilot air supply | Internal or external | |||||||
Flow direction | - | Reversible with external pilot air supply | ||||||
Exhaust air function | - | With flow control | ||||||
Manual override | Non-detenting, detenting via accessory | |||||||
Type of mounting | Via through-holes | |||||||
Mounting position | Any | |||||||
Pneumatic connection | 1, 2, 4 | Threaded connection: G1/8 QS connection: Ø 6 or Ø 8 mm | ||||||
3, 5 | Threaded connection: G1/8 | |||||||
12, 14 | Threaded connection: M3; QS connection: Ø 3 mm | |||||||
82, 84 | Threaded connection: M3 | |||||||
Nominal width [mm] | 6 | |||||||
Standard nominal flow rate G1/8 [l/min] | 900 | 800 | 750 | 700 | ||||
Standard nominal flow rate QS6 [l/min] | 510 | 400 | 410 | 370 | ||||
Standard nominal flow rate QS8 [l/min] | 810 | 680 | 720 | 650 | 570 | |||
Switching time on/off [ms] | 16/27 | 24/32 | - | 20/42 | ||||
Changeover time [ms] | - | 12 | - | |||||
Duty cycle [%] | 100 | |||||||
Width [mm] | 14 | |||||||
Corrosion resistance class CRC | 2 |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | Pneumatic connection 1 | Pneumatic connection 2 | Pneumatic connection 4 | Pneumatic connection 5 | Pneumatic working port | Pilot exhaust air port 84 | Pilot air port 14 | Degree of protection | Valve function | Standard nominal flow rate (l/min) | Pilot air supply port | Flow direction | Changeover time (ms) | Reset method | Switching time off (ms) | Switching time on (ms) | Min. Operating pressure (bar) | Max. Operating pressure (bar) | Min. Pilot pressure (bar) | Max. Pilot pressure (bar) | Pilot medium | Manufacturer part # | Weight (g) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 5,908.85 | SOLENOID VALVES | 1 Piece(s) | 8 Day(s) | G1/8 | G1/8 | - | - | G1/8 | - | - | IP65 | 3/2, closed, monostable | 900 | Internal | Non-reversible | - | Pneumatic spring | 27 | 16 | 2.5 | 8 | - | - | - | 196929 | 60 | ||
฿ 6,247.40 | SOLENOID VALVES | 1 Piece(s) | 8 Day(s) | QS-6 | QS-6 | - | - | QS-6 | - | - | IP65 | 3/2, closed, monostable | 510 | Internal | Non-reversible | - | Pneumatic spring | 27 | 16 | 2.5 | 8 | - | - | - | 196887 | - | ||
฿ 6,277.09 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-8 | QS-8 | - | - | QS-8 | - | - | IP65 | 3/2, closed, monostable | 810 | Internal | Non-reversible | - | Pneumatic spring | 27 | 16 | 2.5 | 8 | - | - | - | 196888 | - | ||
฿ 6,098.89 | SOLENOID VALVES | 1 Piece(s) | 8 Day(s) | G1/8 | G1/8 | - | - | G1/8 | - | - | IP65 | 3/2, closed, monostable | 900 | External | Non-reversible | - | Pneumatic spring | 27 | 16 | -0.9 | 10 | 2.5 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196930 | 60 | ||
฿ 6,692.28 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-6 | QS-6 | - | - | QS-6 | - | - | IP65 | 3/2, closed, monostable | 510 | External | Non-reversible | - | Pneumatic spring | 27 | 16 | -0.9 | 10 | 2.5 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196889 | - | ||
฿ 6,721.40 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-8 | QS-8 | - | - | QS-8 | - | - | IP65 | 3/2, closed, monostable | 810 | External | Non-reversible | - | Pneumatic spring | 27 | 16 | -0.9 | 10 | 2.5 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196890 | - | ||
฿ 5,908.85 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | G1/8 | G1/8 | - | - | G1/8 | - | - | IP65 | 3/2, open, monostable | 900 | Internal | Non-reversible | - | Pneumatic spring | 27 | 16 | 2.5 | 8 | - | - | - | 196931 | 60 | ||
฿ 6,247.40 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-6 | QS-6 | - | - | QS-6 | - | - | IP65 | 3/2, open, monostable | 510 | Internal | Non-reversible | - | Pneumatic spring | 27 | 16 | 2.5 | 8 | - | - | - | 196891 | - | ||
฿ 6,277.09 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-8 | QS-8 | - | - | QS-8 | - | - | IP65 | 3/2, open, monostable | 810 | Internal | Non-reversible | - | Pneumatic spring | 27 | 16 | 2.5 | 8 | - | - | - | 196892 | - | ||
฿ 6,098.89 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | G1/8 | G1/8 | - | - | G1/8 | - | - | IP65 | 3/2, open, monostable | 900 | External | Non-reversible | - | Pneumatic spring | 27 | 16 | -0.9 | 10 | 2.5 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196932 | 60 | ||
฿ 6,692.28 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-6 | QS-6 | - | - | QS-6 | - | - | IP65 | 3/2, open, monostable | 510 | External | Non-reversible | - | Pneumatic spring | 27 | 16 | -0.9 | 10 | 2.5 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196893 | - | ||
฿ 6,721.40 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-8 | QS-8 | - | - | QS-8 | - | - | IP65 | 3/2, open, monostable | 810 | External | Non-reversible | - | Pneumatic spring | 27 | 16 | -0.9 | 10 | 2.5 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196894 | - | ||
฿ 10,560.24 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP65 | 5/3, pressurized | 750 | Internal | Non-reversible | - | Mechanical spring | 42 | 20 | 3 | 8 | - | - | - | 196933 | 120 | ||
฿ 11,069.27 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-6 | QS-6 | QS-6 | G1/8 | QS-6 | M3 | M3 | IP65 | 5/3, pressurized | 370 | Internal | Non-reversible | - | Mechanical spring | 42 | 20 | 3 | 8 | - | - | - | 196895 | - | ||
฿ 11,113.21 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-8 | QS-8 | QS-8 | G1/8 | QS-8 | M3 | M3 | IP65 | 5/3, pressurized | 650 | Internal | Non-reversible | - | Mechanical spring | 42 | 20 | 3 | 8 | - | - | - | 196896 | - | ||
฿ 10,942.75 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP65 | 5/3, pressurized | 750 | External | Reversible | - | Mechanical spring | 42 | 20 | -0.9 | 10 | 3 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196934 | 120 | ||
฿ 11,550.18 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-6 | QS-6 | QS-6 | G1/8 | QS-6 | M3 | M3 | IP65 | 5/3, pressurized | 370 | External | Reversible | - | Mechanical spring | 42 | 20 | -0.9 | 10 | 3 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196897 | - | ||
฿ 11,592.65 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-8 | QS-8 | QS-8 | G1/8 | QS-8 | M3 | M3 | IP65 | 5/3, pressurized | 650 | External | Reversible | - | Mechanical spring | 42 | 20 | -0.9 | 10 | 3 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196898 | - | ||
฿ 10,560.24 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP65 | 5/3, exhausted | 700 | Internal | Non-reversible | - | Mechanical spring | 42 | 20 | 3 | 8 | - | - | - | 196935 | 120 | ||
฿ 11,069.27 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-6 | QS-6 | QS-6 | G1/8 | QS-6 | M3 | M3 | IP65 | 5/3, exhausted | 370 | Internal | Non-reversible | - | Mechanical spring | 42 | 20 | 3 | 8 | - | - | - | 196899 | - | ||
฿ 11,113.21 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-8 | QS-8 | QS-8 | G1/8 | QS-8 | M3 | M3 | IP65 | 5/3, exhausted | 570 | Internal | Non-reversible | - | Mechanical spring | 42 | 20 | 3 | 8 | - | - | - | 196900 | - | ||
฿ 10,942.75 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP65 | 5/3, exhausted | 700 | External | Reversible | - | Mechanical spring | 42 | 20 | -0.9 | 10 | 3 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196936 | 120 | ||
฿ 11,550.18 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-6 | QS-6 | QS-6 | G1/8 | QS-6 | M3 | M3 | IP65 | 5/3, exhausted | 370 | External | Reversible | - | Mechanical spring | 42 | 20 | -0.9 | 10 | 3 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196901 | - | ||
฿ 11,592.65 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-8 | QS-8 | QS-8 | G1/8 | QS-8 | M3 | M3 | IP65 | 5/3, exhausted | 570 | External | Reversible | - | Mechanical spring | 42 | 20 | -0.9 | 10 | 3 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196902 | - | ||
฿ 10,560.24 | SOLENOID VALVES | 1 Piece(s) | 7 Day(s) | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP65 | 5/3, closed | 750 | Internal | Non-reversible | - | Mechanical spring | 42 | 20 | 3 | 8 | - | - | - | 196937 | 120 | ||
฿ 11,069.27 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-6 | QS-6 | QS-6 | G1/8 | QS-6 | M3 | M3 | IP65 | 5/3, closed | 410 | Internal | Non-reversible | - | Mechanical spring | 42 | 20 | 3 | 8 | - | - | - | 196903 | - | ||
฿ 11,113.21 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-8 | QS-8 | QS-8 | G1/8 | QS-8 | M3 | M3 | IP65 | 5/3, closed | 720 | Internal | Non-reversible | - | Mechanical spring | 42 | 20 | 3 | 8 | - | - | - | 196904 | - | ||
฿ 10,942.75 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP65 | 5/3, closed | 750 | External | Reversible | - | Mechanical spring | 42 | 20 | -0.9 | 10 | 3 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196938 | 120 | ||
฿ 11,550.18 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-6 | QS-6 | QS-6 | G1/8 | QS-6 | M3 | M3 | IP65 | 5/3, closed | 410 | External | Reversible | - | Mechanical spring | 42 | 20 | -0.9 | 10 | 3 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196905 | - | ||
฿ 11,592.65 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-8 | QS-8 | QS-8 | G1/8 | QS-8 | M3 | M3 | IP65 | 5/3, closed | 720 | External | Reversible | - | Mechanical spring | 42 | 20 | -0.9 | 10 | 3 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196906 | - | ||
฿ 8,532.41 | SOLENOID VALVES | 1 Piece(s) | 7 Day(s) | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP65 | 5/2, bistable | 800 | Internal | Non-reversible | 13 | - | - | - | 2 | 8 | - | - | - | 196939 | 115 | ||
฿ 9,042.05 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-6 | QS-6 | QS-6 | G1/8 | QS-6 | M3 | M3 | IP65 | 5/2, bistable | 400 | Internal | Non-reversible | 13 | - | - | - | 2 | 8 | - | - | - | 196907 | - | ||
฿ 9,084.79 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-8 | QS-8 | QS-8 | G1/8 | QS-8 | M3 | M3 | IP65 | 5/2, bistable | 680 | Internal | Non-reversible | 13 | - | - | - | 2 | 8 | - | - | - | 196908 | - | ||
฿ 8,913.13 | SOLENOID VALVES | 1 Piece(s) | 8 Day(s) | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP65 | 5/2, bistable | 800 | External | Reversible | 13 | - | - | - | -0.9 | 10 | 2 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196940 | 115 | ||
฿ 9,930.02 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-6 | QS-6 | QS-6 | G1/8 | QS-6 | M3 | M3 | IP65 | 5/2, bistable | 400 | External | Reversible | 13 | - | - | - | -0.9 | 10 | 2 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196909 | - | ||
฿ 9,973.39 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-8 | QS-8 | QS-8 | G1/8 | QS-8 | M3 | M3 | IP65 | 5/2, bistable | 680 | External | Reversible | 13 | - | - | - | -0.9 | 10 | 2 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196910 | - | ||
฿ 6,244.41 | SOLENOID VALVES | 1 Piece(s) | Same day | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP65 | 5/2, monostable | 800 | Internal | Non-reversible | - | Pneumatic spring | 32 | 24 | 3 | 8 | - | - | - | 196941 | 95 | ||
฿ 6,754.66 | SOLENOID VALVES | 1 Piece(s) | 8 Day(s) | QS-6 | QS-6 | QS-6 | G1/8 | QS-6 | M3 | M3 | IP65 | 5/2, monostable | 400 | Internal | Non-reversible | - | Pneumatic spring | 32 | 24 | 3 | 8 | - | - | - | 196911 | - | ||
฿ 6,796.22 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-8 | QS-8 | QS-8 | G1/8 | QS-8 | M3 | M3 | IP65 | 5/2, monostable | 680 | Internal | Non-reversible | - | Pneumatic spring | 32 | 24 | 3 | 8 | - | - | - | 196912 | - | ||
฿ 6,435.08 | SOLENOID VALVES | 1 Piece(s) | 8 Day(s) | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP65 | 5/2, monostable | 800 | External | Reversible | - | Pneumatic spring | 32 | 24 | -0.9 | 10 | 3 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196942 | 95 | ||
฿ 7,198.35 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-6 | QS-6 | QS-6 | G1/8 | QS-6 | M3 | M3 | IP65 | 5/2, monostable | 400 | External | Reversible | - | Pneumatic spring | 32 | 24 | -0.9 | 10 | 3 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196913 | - | ||
฿ 7,241.12 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | QS-8 | QS-8 | QS-8 | G1/8 | QS-8 | M3 | M3 | IP65 | 5/2, monostable | 680 | External | Reversible | - | Pneumatic spring | 32 | 24 | -0.9 | 10 | 3 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196914 | - | ||
฿ 5,801.92 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | G1/8 | G1/8 | - | - | G1/8 | - | - | IP67, IP65 | 3/2, closed, monostable | 900 | Internal | Non-reversible | - | Pneumatic spring | 27 | 16 | 2.5 | 8 | - | - | - | 550247 | 60 | ||
฿ 5,982.48 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | G1/8 | G1/8 | - | - | G1/8 | - | - | IP67, IP65 | 3/2, closed, monostable | 900 | External | Non-reversible | - | Pneumatic spring | 27 | 16 | -0.9 | 10 | 2.5 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 550248 | 60 | ||
฿ 10,358.27 | SOLENOID VALVES | 1 Piece(s) | 30 Day(s) | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP67, IP65 | 5/3, exhausted | 700 | Internal | Non-reversible | - | Mechanical spring | 42 | 20 | 3 | 8 | - | - | - | 550243 | 120 | ||
฿ 10,748.52 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP67, IP65 | 5/3, exhausted | 700 | External | Reversible | - | Mechanical spring | 42 | 20 | -0.9 | 10 | 3 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 550244 | 120 | ||
฿ 10,358.27 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP67, IP65 | 5/3, closed | 750 | Internal | Non-reversible | - | Mechanical spring | 42 | 20 | 3 | 8 | - | - | - | 550241 | 120 | ||
฿ 8,375.60 | SOLENOID VALVES | 1 Piece(s) | 30 Day(s) | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP67, IP65 | 5/2, bistable | 800 | Internal | Non-reversible | 12 | - | - | - | 2 | 8 | - | - | - | 550239 | 115 | ||
฿ 8,754.55 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP67, IP65 | 5/2, bistable | 800 | External | Reversible | 12 | - | - | - | -0.9 | 10 | 2 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 550240 | 115 | ||
฿ 6,137.52 | SOLENOID VALVES | 1 Piece(s) | 8 Day(s) | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP67, IP65 | 5/2, monostable | 800 | Internal | Non-reversible | - | Pneumatic spring | 32 | 24 | 3 | 8 | - | - | - | 550237 | 95 | ||
฿ 6,318.66 | SOLENOID VALVES | 1 Piece(s) | 31 Day(s) | G1/8 | G1/8 | G1/8 | G1/8 | G1/8 | M3 | M3 | IP67, IP65 | 5/2, monostable | 800 | External | Reversible | - | Pneumatic spring | 32 | 24 | -0.9 | 10 | 3 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 550238 | 95 |
Loading...
Housing material | Die-cast aluminum | Seals material | NBR | Pneumatic connection 3 | G1/8 |
---|---|---|---|---|---|
Pilot exhaust air port 82 | M3 | Pilot air port 12 | M3 | Lap | Overlap |
Width(mm) | 14 | Nominal width(mm) | 6 | Operating voltage(V) | 24 DC |
Min. Temperature of medium(°C) | -5 | Max. Temperature of medium(°C) | 50 | Min. Ambient temperature(°C) | -5 |
Max. Ambient temperature(°C) | 50 | Max. positive test pulse with 0 signal(µs) | 1200 | Max. negative test pulse on 1 signal(µs) | 900 |
Operating medium | Compressed air as per ISO 8573-1:2010 [7:4:4] | Corrosion resistance class (CRC) | 2 - Moderate corrosion stress |