Pressure Gauge With Color Zone Limit Indicator G36-L/G46-L Series

Caution
- Product images may be representative images. Refer to the manufacturer's catalog for details
Product Description
[Features]
· Red and green colored zones improve visibility of the pressure control range
· Indicator range can be adjusted freely
Pressure Gauge With Color Zone Limit Indicator G36-L/G46-L Series Specifications

G36-10-01-L external appearance

G46-10-02-L external appearance

Indicator with red and green zone segments

Indicator range can be adjusted freely
Standard specification
| Model | G36-L | G46-L | |
|---|---|---|---|
| Shape | Back side thread | ||
| Port size*1 | R 1/8 | R1/8, R1/4 | |
| Fluid*2*3 | Air | ||
| Indication precision*4 | ±3% F.S. (full span) | ||
| Material | Case (surface treatment) | Stainless steel (black melamine painted) | |
| Clear cover | Polycarbonate (part number: G36-00-00-3) Nylon (part number: G36-00-00-3N) | Polycarbonate (part number: G46-00-00-3) Nylon (part number: G46-00-00-3N) | |
| Stud | Brass | ||
| Bourdon tube | Brass | ||
| Weight (kg) | 0.04 | 0.05 | |
| Attachment: With cover ring assembly | C | - | Part number: 1305104-1A |
| C1 | Part number: 1305104-3A | ||
| C2 | Part number: 1305104-9A | ||
*1: When mounting a pressure gauge on products, take care not to over-tighten. Excessive tightening will cause damage. Use pipe tape for sealing.
*2: Before using other fluids, please contact the manufacturer's support center as there may be a corrosion problem.
*3: Take care to avoid freezing. This may result in a malfunction.
*4: The guaranteed temperature range is 23°C ±5°C.
Model
| Model | Pressure range* | Green zone setting range | Indication unit | Port size | Note | |
|---|---|---|---|---|---|---|
| MPa | Minimum setting range MPa | Maximum setting range MPa | ||||
| G36-2-01-L□ | 0 to 0.2 | 0.01 | 0.1 | MPa | R 1/8 | - |
| G36-4-01-L□ | 0 to 0.4 | 0.02 | 0.2 | |||
| G36-10-01-L□ | 0 to 1.0 | 0.05 | 0.5 | |||
| G46-2-01 to 02-L□ | 0 to 0.2 | 0.01 | 0.1 | R 1/8 1/4 | ||
| G46-4-01 to 02-L□ | 0 to 0.4 | 0.02 | 0.2 | |||
| G46-10-01 to 02-L□ | 0 to 1.0 | 0.05 | 0.5 | |||
*: Do not exceed the maximum pressure. This may result in a malfunction.
| Model | Pressure range*1 | Green zone setting range | Indication unit | Port size | Note | ||
|---|---|---|---|---|---|---|---|
| MPa | psi | Minimum setting range MPa (psi) | Maximum setting range MPa (psi) | ||||
| G36-P2-01-L□-X30 | 0 to 0.2 | 0 to 30 | 0.01 (2) | 0.1 (14) | MPa psi | R 1/8 | - |
| G36-P4-01-L□-X30 | 0 to 0.4 | 0 to 60 | 0.02 (4) | 0.2 (28) | |||
| G36-P10-01-L□-X30 | 0 to 1.0 | 0 to 150 | 0.05 (10) | 0.5 (70) | |||
| G46-P2-01 to 02-L□-X30 | 0 to 2.0 | 0 to 30 | 0.01 (2) | 0.1 (14) | R 1/8 1/4 | ||
| G46-P4-01 to 02-L□-X30 | 0 to 0.4 | 0 to 60 | 0.02 (4) | 0.2 (28) | |||
| G46-P10-01 to 02-L□-X30 | 0 to 1.0 | 0 to 150 | 0.05 (10) | 0.5 (70) | |||
*1: Do not exceed the maximum pressure. This may result in a malfunction.
*2: Under new Japanese measurement laws, the products available for sale inside of Japan are the SI unit type.
- *See the manufacturer's catalog for information other than the above.