CCVS/CCVL Series Valve Unit (Large Flow / Small Flow)

Caution
- Product images may be representative images. Refer to the manufacturer's catalog for details
Product Description
Valve unit for converter.
[Features]
· Valve unit size: small flow / large flow.
· Control valve: none, flow control valve (with pressure compensation), throttle valve, timid flow control valve (only CCVS Series).
· Combined valve: none*, stop valve + skip valve, stop valve, skip valve.
*When combined valve is "none", no solenoid valve is included.
· Electrical entry of solenoid valve: air operated, grommet, DIN terminal.
· Applicable converter: small flow, 63 mm / 100 mm, large flow, 100 mm / 160 mm.
Valve Unit CCVS/CCVL Series Specifications

Valve Unit CCVS/CCVL Series external appearance
| Specifications | Combined valve | Control valve | ||||||
|---|---|---|---|---|---|---|---|---|
| Stop valve + skip valve | Throttle valve | Flow control valve | ||||||
| Small flow | High flow rate shape | Small flow | High flow rate shape | Timid flow | Small flow | High flow rate shape | ||
| Operating pressure | 0 to 0.7 MPa | 0 to 0.7 MPa | 0.3 to 0.7 MPa | |||||
| External pilot pressure | 0.3 to 0.7 MPa | - | - | |||||
| Proof pressure | 1.05 MPa | |||||||
| Ambient and fluid temperature | 5 to 50°C | |||||||
| Fluid | Turbine oil (40 to 100 mm2/s) | |||||||
| Effective area (mm2) | Stop valve + skip valve | 40 | 88 | - | ||||
| Control valve free open | - | 35 | 77 | 18 | 24 | 60 | ||
| Control valve free flow | - | 30 | 80 | 23 | 30 | 80 | ||
| Minimum control flow (dm3/min) | - | 0.3 | 0.04 | 0.06 | ||||
| Pressure compensating ability | - | - | ±10% | |||||
| Pressure compensating range | - | - | Load ratio: 60% compared to theoretical output | |||||
| Valve type | N.C. | - | - | |||||
Solenoid Valve Specifications of Combined Valve (Stop Valve + Skip Valve)
| Solenoid valve model | VO307-□□1 | ||
|---|---|---|---|
| External pilot pressure | 0.3 to 0.7 MPa | ||
| Coil rated voltage V | AC (50/60 Hz) | 100, 200, 110, 220, 240 | |
| DC | 24, 12 | ||
| Apparent power*1 | AC | Inrush | 12.7 VA (50 Hz) 10.7 VA (60 Hz) |
| Holding | 7.6 VA (50 Hz) 5.4 VA (60 Hz) | ||
| DC | 4 W | ||
| Electrical entry | Grommet (standard), DIN terminal | ||
*1 When rated voltage is applied
Solenoid Valve Function Plate
| Solenoid valve style | *N.C. | **N.O. | |
|---|---|---|---|
| Valve type | Stop valve | Not displayed | N.O. |
| Stop valve | N.O. | Not displayed | |
*Valve opens when solenoid valve conducts electricity.
**Valve opens when solenoid valve stops conducting electricity.
Dimensional Drawing

CCVS/CCVL Series Valve Unit dimensional drawing
(Unit: mm)
| Model | Oil port size Rc | A | B | *CA | *CL | F | GA | GB | GL | KA |
|---|---|---|---|---|---|---|---|---|---|---|
| CCVS02-□G-S | 1/2 | - | - | 72 | 36 | 35 | 18 | 35 | 101 | 86 |
| CCVS□1-□G-S | 1/2 | 121.8 | 98 | 72 | 36 | 35 | 18 | 35 | 101 | 86 |
| CCVS□2-□G-S | 1/2 | - | 98 | 72 | 36 | 35 | 18 | 35 | 101 | 86 |
| CCVS□3-□G-S | 1/2 | - | 98 | 72 | 36 | 35 | 18 | 35 | 101 | 86 |
| CCVS□0-S | 1/2 | - | 98 | 72 | 36 | - | - | 35 | - | 86 |
| CCVL02-□G-S | 3/4 | - | - | 100 | 40 | 40 | 24 | 50 | 135 | 116 |
| CCVL□1-□G-S | 3/4 | 132.8 | 135 | 100 | 40 | 40 | 24 | 50 | 135 | 116 |
| CCVL□2-□G-S | 3/4 | - | 135 | 100 | 40 | 40 | 24 | 50 | 135 | 116 |
| CCVL□3-□G-S | 3/4 | - | 135 | 100 | 40 | 40 | 24 | 50 | 135 | 116 |
| CCVL□0-S | 3/4 | - | 135 | 100 | 40 | - | - | 50 | - | 116 |
| Model | KB | KL | L | M | NB | NL | QA | QB | QL | R | S | T |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CCVS02-□G-S | 45 | 80 | 148.5 | - | 17.5 | 25 | 103.9 | 45 | 88.2 | 1 | M5 × 0.8 | 5.4 to 7.5 |
| CCVS□1-□G-S | 45 | 80 | 148.5 | 57 | 17.5 | 25 | - | - | - | 2 | ||
| CCVS□2-□G-S | 45 | 80 | 148.5 | 57 | 17.5 | 25 | 103.9 | - | 88.2 | 1 | ||
| CCVS□3-□G-S | 45 | 80 | 148.5 | 57 | 17.5 | 25 | 103.9 | - | 88.2 | 1 | ||
| CCVS□0-S | 45 | 80 | - | 57 | 17.5 | 25 | - | - | 88.2 | - | ||
| CCVL02-□G-S | 66 | 107 | 180.5 | - | 27 | 28 | 124.9 | 62 | 115 | 1 | M6 × 1 | 10.5 to 12.5 |
| CCVL□1-□G-S | 66 | 107 | 180.5 | 80 | 27 | 28 | - | - | - | 2 | ||
| CCVL□2-□G-S | 66 | 107 | 180.5 | 80 | 27 | 28 | 124.9 | - | 115 | 1 | ||
| CCVL□3-□G-S | 66 | 107 | 180.5 | 80 | 27 | 28 | 124.9 | - | 115 | 1 | ||
| CCVL□0-S | 66 | 107 | - | 80 | 27 | 28 | - | - | 115 | - |
- *Pitch of mounting on the wall is CA and CL.
Precautions
- *Air supply: A mist separator prevents the intermixing of drainage, preventing the air hydro unit from malfunctioning, and prolonging the life of the oil.
- *Environment: Avoid use near fire.
- *Environment: Cannot be used in a clean room.